SDS6000A actualización de firmware
Versión: V2.0.6.14
Fecha de actualización: 11/11/2026
Actualizaciones

1. UI process control, which improves UI processing efficiency

2. Added the feature to limit the number of display digits of measurements

3. Added a Run/Stop button to the Quick Settings panel

4. Roll mode now supports Track cursors and measurement statistics; Math is supported in Roll mode when the acquisition is stopped

5. Cursors: supports multiple cursor groups (multiple cursors)

6. Measure:
a) Added measurement items: Bit Rate and Data Rate;
b) Tapping a measurement item opens a pop-up dialog for quick setup of measurement parameters;
c) In M2 display mode of advanced measurement, up to 24 measurement items can be displayed simultaneously; supports Time@Level, △TimeMax, △TimeMin, Track plot (for small-target measurement), Math Track plot, Trend plot, and Math Trend plot

7. Bus protocols: supports USB 2.0, CAN XL, SpaceWire, SPMI, 8b10b, and RFFE

8. Option types: added USB 2.0, CAN XL, SpaceWire, SPMI, 8b10b, and RFFE options

9. File storage: supports saving all frames of Sequence data into a single file — the multi-frame storage function is enabled once Sequence is turned on; also supports saving multiple channels into a single file

10. Added password setting for the screen saver

11. Added Math and memory waveforms as selectable sources

12. Added operators: FFTPhs, tan, and atan

13. Optimized FFT measurement performance

Created with Pixso.
Descargar Created with Pixso.
SSG6000A actualización de firmware
Versión: V1.0.1.3.8
Fecha de actualización: 20/10/2026
Actualizaciones

1. Add support for HP accessories

2. Add temperature display on the self-test page

3. Resolve some glitches and spurious issues

4. Add new calibration items

Created with Pixso.
Descargar Created with Pixso.
SDM4055A actualización de firmware
Versión: V0.0.0.13
Fecha de actualización: 18/09/2026
Actualizaciones

1. Supports saving and recalling configuration files under remote control.

2. Supports configuration file upgrade under Webserver.

3. Bug fixes

a. The measurement result save time is incorrect under the scan card.
b. The trend chart is faulty under the scan card.
c. Trigger and acquisition errors occur under the scan card.
d. ACI/Freq and ACI/period switching are not supported under dual display.
e. The center value setting is abnormal under the histogram.
f. After *RST, dual display configuration and statistics reset are abnormal.

Created with Pixso.
Descargar Created with Pixso.
SDM4065A actualización de firmware
Versión: V0.0.0.22R1
Fecha de actualización: 04/09/2026
Actualizaciones

1. Supports RE model.

2. Solve the problem of inaccurate measurement values under the 200V range of DCV.

3. Bug fixes

a) Restore the default trigger source error under Cont function.
b) Opening the statistics menu causes the probehold menu to disappear.
c) Optimize the prompt window under the Data Log menu and the trend chart display issue.
d) When the Power On mode is Last, the switch between the temp and cont functions is abnormal.
e) The number of sampling points exceeds 2M and the timestamp is incorrect.
f) When the trigger source is an external trigger, the trigger status changes to automatic after the abort instruction.
g) Support the transmission of scanner card data timestamps.
h) Setting the Socket parameter to MAX causes the system to freeze.
i) Remotely enable relative values, send *RST, and switch to local trigger without reading.
j) The sampling interval of the Data Log cannot be set to 3600s.
k) When the DCI range is switched, the range obtained by the instruction is inconsistent with the UI.

Created with Pixso.
Descargar Created with Pixso.
SNA6000A actualización de firmware
Versión: V1.0.0.2.16
Fecha de actualización: 27/08/2026
Actualizaciones

Features and Enhancements:

  • 1. Added GCX measurement mode.
  • 2. Added harmonic analysis measurement function in SA measurement mode.
  • 3. Added full-channel calibration function.
  • 4. Added calibration information display function.
  • 5. Added power compensation function for fixture simulation.
  • 6. Added ECal (Electronic Calibration) characterization function.
  • 7. Added Compression Point Search / Saturation Point Search / Normal Operating Point Search functions.
  • 8. Added Preferences settings.
  • 9. Mixer Measurement Mode: Now supports dual LO (Local Oscillator) function.
  • 10. TDR Measurement Mode: Now supports extended port function.
  • 11. GC Measurement Mode: Now supports extended port function.
  • 12. AFR (Automatic Fixture Removal): Now supports timedomain trace display.
  • 13. Minimum Sweep Points: Now supports a minimum setting of 1 point.
  • 14. File Manager: Added support for “Favorites” and “History” functions.
  • 15. Power Meter: Added support for IP connection.
  • 16. Power Meter Reading: Default frequency changed to 50 MHz.
  • 17. Switch Matrix: Added support for characterization and deembedding functions.

Bug Fixes:

  • 1. Fixed the issue where single-ended measurements (e.g., Sss11) would not sweep under balanced measurement mode.
  • 2. Fixed the issue where smoothing results were abnormal under the Phase format.
  • 3. Fixed the issue where traces might appear abnormal after executing a calibration data overwrite.
  • 4. Fixed the issue where the power calibration progress bar might display incorrectly.
  • 5. Fixed the issue where trace data became abnormal after recalling CSV files saved from Power Sweeps or CW Sweeps.
  • 6. Fixed the issue where the sweep would hang when the external trigger signal frequency was high in “Point Trigger” mode.
  • 7. Fixed the issue where the log display time might be incorrect.
  • 8. Fixed the issue where the phase of each port might not be fixed after the device powers on.
  • 9. Fixed abnormal UI control behavior in the SA measurement mode configuration dialog.
  • 10. Fixed the issue where eye diagram data might be abnormal after modifying the rise time in TDR measurement mode.
Created with Pixso.
Descargar Created with Pixso.
SDG8000A actualización de firmware
Versión: V1.1.1.7R19
Fecha de actualización: 17/08/2026
Descargar Created with Pixso.
SNA5000X-E actualización de firmware
Versión: V1.0.0.2.16
Fecha de actualización: 17/08/2026
Actualizaciones

Features and Enhancements:

1. Added harmonic analysis measurement function in SA measurement mode.

2. Added full-channel calibration function.

3. Added calibration information display function.

4. Added power compensation function for fixture simulation.

5. Added ECal (Electronic Calibration) characterization function.

6. Added Compression Point Search / Saturation Point Search / Normal Operating Point Search functions.

7. Added Preferences settings.

8. TDR Measurement Mode: Now supports extended port function.

9. AFR (Automatic Fixture Removal): Now supports timedomain trace display.

10. Minimum Sweep Points: Now supports a minimum setting of 1 point.

11. File Manager: Added support for “Favorites” and “History” functions.

12. Power Meter: Added support for IP connection.

13. Power Meter Reading: Default frequency changed to 50 MHz.

14. Switch Matrix: Added support for characterization and deembedding functions.

Bug Fixes:

1. Fixed the issue where single-ended measurements (e.g., Sss11) would not sweep under balanced measurement mode.

2. Fixed the issue where smoothing results were abnormal under the Phase format.

3. Fixed the issue where traces might appear abnormal after executing a calibration data overwrite.

4. Fixed the issue where the power calibration progress bar might display incorrectly.

5. Fixed the issue where trace data became abnormal after recalling CSV files saved from Power Sweeps or CW Sweeps.

6. Fixed the issue where the sweep would hang when the external trigger signal frequency was high in “Point Trigger” mode.

7. Fixed the issue where the log display time might be incorrect.

8. Fixed abnormal UI control behavior in the SA measurement mode configuration dialog.

9. Fixed the issue where eye diagram data might be abnormal after modifying the rise time in TDR measurement mode.

Created with Pixso.
Descargar Created with Pixso.
SDG3000X actualización de firmware
Versión: V1.1.1.7R12
Fecha de actualización: 14/08/2026
Actualizaciones

1.Optimized Multitone function

2.AWG Added single waveform setting UI

3.Resolved an issue where the UI would occasionally fail to display during startup.

4.Resolved an issue where startup would occasionally fail.

5.Fixed an output error when manually triggering in IQ mode.

Created with Pixso.
Descargar Created with Pixso.
SNA5022A&SNA5032A actualización de firmware
Versión: V1.0.0.2.16
Fecha de actualización: 12/08/2026
Actualizaciones

Features and Enhancements:

  • 1. Added GCX measurement mode.
  • 2. Added harmonic analysis measurement function in SA measurement mode.
  • 3. Added full-channel calibration function.
  • 4. Added calibration information display function.
  • 5. Added power compensation function for fixture simulation.
  • 6. Added ECal (Electronic Calibration) characterization function.
  • 7. Added Compression Point Search / Saturation Point Search/ Normal Operating Point Search functions.
  • 8. Added Preferences settings.
  • 9. Mixer Measurement Mode: Now supports dual LO (Local Oscillator) function.
  • 10. TDR Measurement Mode: Now supports extended port function.
  • 11. GC Measurement Mode: Now supports extended port function.
  • 12. AFR (Automatic Fixture Removal): Now supports timedomain trace display.
  • 13. Minimum Sweep Points: Now supports a minimumsetting of 1 point.
  • 14. File Manager: Added support for “Favorites” and”History” functions.
  • 15. Power Meter: Added support for IP connection.
  • 16. Power Meter Reading: Default frequency changed to 50 MHz.
  • 17. Switch Matrix: Added support for characterization andde-embedding functions.

Bug Fixes:

  • 1. Fixed the issue where single-ended measurements (e.g., Sss11) would not sweep under balanced measurement mode.
  • 2. Fixed the issue where smoothing results were abnormal under the Phase format.
  • 3. Fixed the issue where traces might appear abnormal after executing a calibration data overwrite.
  • 4. Fixed the issue where the power calibration progress bar might display incorrectly.
  • 5. Fixed the issue where trace data became abnormal after recalling CSV files saved from Power Sweeps or CW Sweeps.
  • 6. Fixed the issue where the sweep would hang when the external trigger signal frequency was high in “Point Trigger” mode.
  • 7. Fixed the issue where the log display time might be incorrect.
  • 8. Fixed abnormal UI control behavior in the SA measurement mode configuration dialog.
  • 9. Fixed the issue where eye diagram data might be abnormal after modifying the rise time in TDR measurement mode.
Created with Pixso.
Descargar Created with Pixso.
SNA5000A actualización de firmware
Versión: V1.0.0.2.16
Fecha de actualización: 12/08/2026
Actualizaciones

Features and Enhancements:

  • 1. Added GCX measurement mode.
  • 2. Added harmonic analysis measurement function in SA measurement mode.
  • 3. Added full-channel calibration function.
  • 4. Added calibration information display function.
  • 5. Added power compensation function for fixture simulation.
  • 6. Added ECal (Electronic Calibration) characterization function.
  • 7. Added Compression Point Search / Saturation Point Search/ Normal Operating Point Search functions.
  • 8. Added Preferences settings.
  • 9. Mixer Measurement Mode: Now supports dual LO (Local Oscillator) function.
  • 10. TDR Measurement Mode: Now supports extended port function.
  • 11. GC Measurement Mode: Now supports extended port function.
  • 12. AFR (Automatic Fixture Removal): Now supports timedomain trace display.
  • 13. Minimum Sweep Points: Now supports a minimumsetting of 1 point.
  • 14. File Manager: Added support for “Favorites” and”History” functions.
  • 15. Power Meter: Added support for IP connection.
  • 16. Power Meter Reading: Default frequency changed to 50 MHz.
  • 17. Switch Matrix: Added support for characterization andde-embedding functions.

Bug Fixes:

  • 1. Fixed the issue where single-ended measurements (e.g., Sss11) would not sweep under balanced measurement mode.
  • 2. Fixed the issue where smoothing results were abnormal under the Phase format.
  • 3. Fixed the issue where traces might appear abnormal after executing a calibration data overwrite.
  • 4. Fixed the issue where the power calibration progress bar might display incorrectly.
  • 5. Fixed the issue where trace data became abnormal after recalling CSV files saved from Power Sweeps or CW Sweeps.
  • 6. Fixed the issue where the sweep would hang when the external trigger signal frequency was high in “Point Trigger” mode.
  • 7. Fixed the issue where the log display time might be incorrect.
  • 8. Fixed abnormal UI control behavior in the SA measurement mode configuration dialog.
  • 9. Fixed the issue where eye diagram data might be abnormal after modifying the rise time in TDR measurement mode.
Created with Pixso.
Descargar Created with Pixso.
SDS7000A actualización de firmware
Versión: V1.3.1.20
Fecha de actualización: 29/07/2026
Actualizaciones

1. Optimized UI response in the case of long waveform depth

2. Added Spectrum Analysis mode

3.Channel: in Eres mode to display the corresponding bandwidth information in the descriptor box

4.Decode: Added SPMI, Spacewire, 8B/10B, MIPI-RFFE

5.Measure:
a)Added item: Bit Rate, Data rate, △TimeMax, △TimeMin
b)Supported to limit the display digits of measure

6.Memory: Supported to import a file with data of multi-channel

7.Analysis:
a)Eye /Jitter upgraded to 2.0: optimized UI; added explicit clock; supported Equalization; supported Noise analysis; supported differential source; supported F1-F4, M1-M4 as source
b)Compliance Test: added 10BASE-T, 10BASE-T1S, DDR4, PCIe 1.0/2.0
c)Serial Signal Test: added I2C, SPI
d)Bode plot: added crossover frequency measure

8. Probe: Supported SAP8000D probe

9.Roll:
a)Supported Math and track cursors in Stop mode
b)Supported bandwidth limit

10.Webserver: supported inverted screenshot (according to the Image style setting in the Save menu)

11.Save/recall: File Manager: Supported to Select All; Supported to save all frames to a single file in Sequence mode

12.UI:Supported to specify Zoom region by drag a rectangle

13.Utility:Added English help; Supported password for screen saver

14. Fixed several bugs
a) When Log horizontal is used in FFT numbers are scrambled
b) Vertical axis of FFT optimized
c) Grid not aligned with numbers/wrong place with large offset
d)100BASE-T1 compliance test: displayed units of test result and judgment criteria are inconsistent
e) 100Base-TX and 1000Base-T: algorithm optimized
f) USB 2.0: compatible issue with USB IF recommended fixture
g) 1000BASE-T: transmission distortion test automatically executes without confirmation after completing one pair under the pairALL differential probe test

Created with Pixso.
Descargar Created with Pixso.
Ubuntu-VSA_1.1.1.1.8R1(Linux)
Versión: V1.1.1.1.8R1
Fecha de actualización: 07/07/2026
Descargar Created with Pixso.
SDS6000L actualización de firmware
Versión: V2.0.3.7
Fecha de actualización: 03/07/2026
Actualizaciones

Compatible with hardware version with 32 GB internal storage

Created with Pixso.
Descargar Created with Pixso.
SSG6082A-V actualización de firmware
Versión: V1.0.0.7.6
Fecha de actualización: 03/07/2026
Actualizaciones

1.Optimize vector signal quality
2.HW Information displays the hardware serial number.
3.Remove “None” from the Custom filter type.
4.Added filter settings to ARB waveform settings.
5.Remove filter settings in ARB settings.
6.Added armed auto mode to ARB trigger.
7.The maximum number of multitone has been increased to 25001.
8.Supports playback of GSM, DAB, and WCDMA protocol waveforms.
9.Added automatic startup for SMB server and supports setting SMB server password.

10.Fixed several bugs
a)SCPI modulator attenuation type display instruction error.
b)Switching LF on the LF source page will not refresh the LF icon at the top.
c)TXT file playback error.
d)When playing txt and wdbin files, a local folder is generated in the root directory.

Created with Pixso.
Descargar Created with Pixso.
SPD1305X actualización de firmware
Versión: V2.1.2.12R3
Fecha de actualización: 26/06/2026
Actualizaciones

1. Add the *RST command..

Created with Pixso.
Descargar Created with Pixso.
SPD1168X actualización de firmware
Versión: V2.1.2.12R3
Fecha de actualización: 26/06/2026
Actualizaciones

1. Add the *RST command..

Created with Pixso.
Descargar Created with Pixso.
SDG2000X actualización de firmware
Versión: V2.01.01.39R7
Fecha de actualización: 26/06/2026
Actualizaciones

1. Supports webserver (0x6 version hardware); adds virtual panel in web control mode.

2. Screenshots support PNG file format.

3. Adds low-resolution output mode to DC output.

4. Sweep add step mode.

Created with Pixso.
Descargar Created with Pixso.
SDM3055 actualización de firmware
Versión: V1.02.01.29R1
Fecha de actualización: 26/06/2026
Actualizaciones

1. Add automatic power-on function.
2. Issues Fixed

a)Fixed abnormal return value issue of ROUT:DATA? command.
b)Fixed scanner lower limit not saving after power cycle.
c)Fixed possible data loss and freeze during data logging via USB flash drive.
Created with Pixso.
Descargar Created with Pixso.
SMM3000X Labview Driver
Versión:
Fecha de actualización: 26/06/2026
Descargar Created with Pixso.
SDS1002X-E Firmware Update
Versión: V1.3.28
Fecha de actualización: 26/06/2026
Actualizaciones

Fixed some bugs:
1. SCPI instruction configuration exception when inactive channel is set as trigger source.
2. Under the interpolation time base, CSV files need to save the original sampling points, not the interpolated points.
3. After recalling the settings file, sometimes the cursor settings are incorrect.
4. In tracking mode, using the SCPI command to change the source of an X cursor will cause the sources of X1 and X2 to change simultaneously.
5. After setting the reference level for FFT, power down and restart to restore the reference level error.
6. In the average sampling mode, when the time base is modified under a large time base, the waveform does not clear the old sampling points.
7. SCPI instruction reads FFT cursor, returns incorrect unit.
8. Sometimes UART decoding stop bit judgment error.
9. When the unit is mHz, the frequency value read by SCPI is in MHz units, which confuses uppercase and lowercase.

Created with Pixso.
Descargar Created with Pixso.
SDG800 actualización de firmware
Versión: V1.08.01.15R8
Fecha de actualización: 26/06/2026
Actualizaciones

1. Resolved the issue where SDG800 bandwidth upgrades did not take effect immediately and required a restart.

Created with Pixso.
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V1.0.2
Fecha de actualización: 26/06/2026
Actualizaciones

1.Display: Supported 100ms, 200ms, 500ms persistence;Supported large font;Optimized the display of custom probe attenuation in the channel description box
2.Fixed several bugs:
a)In Normal trigger mode after one minute the waveform will be refreshed automatically
b)In edge trigger mode Alternating can only trigger on rising edge or falling edge
c)In roll mode level of pattern trigger cannot be set

Created with Pixso.
Descargar Created with Pixso.
SHA850A actualización de firmware
Versión: V1.8R10
Fecha de actualización: 26/06/2026
Actualizaciones

Solved Issues:

  • Update the charging solution to resolve charging issues in certain scenarios.
  • Optimize the coupling logic between the number of points and RBW/Step/Span in EMI mode.
  • Fixe demodulation failures in certain scenarios under DMA mode.
Created with Pixso.
Descargar Created with Pixso.
SHA860A actualización de firmware
Versión: V1.6R10
Fecha de actualización: 26/06/2026
Actualizaciones

New Functionality:

  • Add PowerMeter Mode.

Solved lssues:

  • Updated charging solution to resolve some charging issues in some scenarios.
  • EMl mode: Optimized the coupling logic between RBW/Step/Span etc.
  • DMA mode: Resolved some demodulation issues in some scenarios.
Created with Pixso.
Descargar Created with Pixso.
SSA5000A actualización de firmware
Versión: V1.9.0.2.3R10
Fecha de actualización: 26/06/2026
Actualizaciones

Solved Issues:

  • IQA Mode: Fix the issue of averaging invalidation.
  • MA Mode: Add the import/export function for constellation diagram editing configurations;Add some commands for setting APSK32
  • NF Mode: Modify the minimum value of the frequency multiplication numerator/denominator to 1.
  • PU Mode: Not support negative pulses analysising, and convert them to positive pulses.
  • RTSA Mode: Add multiple marker display.
  • PN Mode: Fix the issue of Correction save failure after editing.
  • EMI Mode: Reset both RBW/Step to 1 when switching CISPR frequency bands, to avoid excessive data points.
  • SYS: Add option descriptions.
Created with Pixso.
Descargar Created with Pixso.
SSG3000X actualización de firmware
Versión: V1.1.4.0.7R3
Fecha de actualización: 26/06/2026
Actualizaciones

1.Modified the return of * OPT and added custom IDN and OPT
2.Added LXI
3.Add SCPI command recording function
4.Fixed some bugs
a) Resolve the issue of not reducing the option numbers of uses
b) Resolve the issue of incorrect power in certain situations

Created with Pixso.
Descargar Created with Pixso.
SNA5000X-E Firmware Update
Versión: V1.0.0.2.15.R2
Fecha de actualización: 26/06/2026
Actualizaciones

Bug Fixes:
1. Fixed issue with Reverse Response Thru Calibration.
2. Fixed issue with log dialog.
3. Fixed issue with recalling state file by SCPI.
4. Fixed issue with abnormal power of SA function under specific conditions.

Created with Pixso.
Descargar Created with Pixso.
SHS800X/SHS1000X Firmware Update
Versión: V1.1.25
Fecha de actualización: 26/06/2026
Actualizaciones

1. Support adjustment of cursor result display position.
2. Support displaying the average sampling count in the lower right corner of the screen.
3. Support knob acceleration function for cursor value and derivative step.
4. Support setting Math vertical offset and derivative step through the keypad.
5. Optimize trace colors after screen invert (C1 as yellow, C2 as green).
6. Fixed several bugs:

a) Issue where channel invert setting is not saved after reboot..
b) Issue with universal knob indicator light status error.
c) Issue when the menu is hidden, opening History or Search does not show the menu.
d) Issue when measure gate at the screen boundary, the device cannot be powered on after reboot.
e) Issue of missing prompt when adjusting parameters with knob in FFT split-screen mode.
f) Issue where reference label was displayed incorrectly when obscured by menu.
g) Issue of inaccurate AC measurement when inputting large offset AC signal.

Created with Pixso.
Descargar Created with Pixso.
SigVSA Vector Signal Analysis Software(Windows)
Versión: V1.1.1.1.8R4
Fecha de actualización: 26/06/2026
Descargar Created with Pixso.
SigIQPro Signal Generation Software
Versión: V2.0.0.2.9R1
Fecha de actualización: 27/03/2026
Descargar Created with Pixso.
SigScopeLab Signal Analysis Software
Versión: V0.6.4.5
Fecha de actualización: 27/03/2026
Descargar Created with Pixso.
SDG1000X/2000X/6000X LabVIEW
Versión: V1.0.2
Fecha de actualización: 17/03/2026
Descargar Created with Pixso.
SDS1004X-E Operating System(Only For 4-Channel)
Versión: OSV2
Fecha de actualización: 17/03/2026
Descargar Created with Pixso.
SDG2000X actualización de firmware
Versión: V2.01.01.38R4
Fecha de actualización: 15/03/2026
Actualizaciones

1. Solve the problem of output desynchronization when
modulation depth/phase deviation/frequency deviation
is changed in channel tracking mode with AM/PM/FM
modulation
2. Solve the problem of abnormal output waveform when
switching back to the internal clock when the external
reference clock is abnormal.
3. Solve the problem of occasional abnormal output
waveform after power on
4. Add the function of long pressing store/recall to save
screenshots

Created with Pixso.
Descargar Created with Pixso.
SLA1016 actualización de firmware (Optional For 4-Channel)
Versión: V8.1.16
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDG7000A actualización de firmware
Versión: V1.1.1.29R8
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fix the bug of pulse output error under specific
configuration
2. Support amplitude sweep function
3. Support the adjustment of channel skew
4. Support multi-file operation in the file manager
5. The digital channel does not support sequence output
6. Optimize the storage strategy of waveform data in
sequence playback
7. Support the playback of bin files exported by the
oscilloscope containing multiple frames
8. The PRBS rate up to 625Mbps
9. Fix the bug of abnormal signal output during waveform
switching

Created with Pixso.
Descargar Created with Pixso.
SDS6000A actualización de firmware
Versión: V1.4.4.1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Force trigger strategy changed (same as SDS2000X HD)
2. Save/Recall
a) Supported to save all sequence segments
b) Supported Auto Save
3. Fixed several bugs
a) Cannot communicate with the SDG2000X and SDG7000A over
USB in Bode Plot
b) Random +/-200 ps skew between channels after power/reboot
cycle
c) [Power analysis] – Switching losses – Error in calculations
d) FFT wrong vertical scale
e) Memory channel trace always on top

Created with Pixso.
Descargar Created with Pixso.
SNA5000A actualización de firmware
Versión: V1.0.0.2.10.R10
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add user manual calibration and verification function (optional)
2. Increasing the number of vertical grids allows for the setting of functions
3. Add vertical axis support for logarithmic display function
4. Add point limit function

Created with Pixso.
Descargar Created with Pixso.
SDS1000CML+actualización de firmware
Versión: V6.01.01.25
Fecha de actualización: 15/03/2026
Actualizaciones

Compatible with new hardware

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: V3 (Only For 4-Channel models)
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.5.2R2
Fecha de actualización: 15/03/2026
Actualizaciones

Fixed a calibration bug only existing on Rev.G hardware (06-xx)

Created with Pixso.
Descargar Created with Pixso.
SNA5000A actualización de firmware
Versión: V1.0.0.2.10.R9
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add scalar mixer measurement function
2. Adjust and optimize the spectrum analysis measurement interface

Created with Pixso.
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V0.9.7R5
Fecha de actualización: 15/03/2026
Actualizaciones

1. Optimized frequency response of 350 MHz model

2. Fixed several bugs

a) Screenshot Save Info Box does not close automatically

b) Random +/-400 ps skew between channels after power cycle

c) No display from Web Server if the scope boots with a USB device connected

Created with Pixso.
Descargar Created with Pixso.
SPD3303C actualización de firmware
Versión: V1.02.01.02.02
Fecha de actualización: 15/03/2026
Actualizaciones

1. This firmware only supports SPD3303C with hardware version V2.0
Note:

  • Machines with hardware version V2.0 do not support rolling back to previous firmware versions
  • Machines with hardware version V1.0 do not support upgrading to this version
  • Long press and hold the “NO.1~5” button for 2 seconds, and release it to display H2.0, which is the V2.0 hardware version


2. Need to upgrade using EasyPower (P20 version)

Created with Pixso.
Descargar Created with Pixso.
SDS2000X HD actualización de firmware
Versión: V1.2.1.1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Math: filter supported

2. Optimized knob acceleration

3. Force trigger strategy changed

4. Fixed several bugs
a) Scope gets confused about time zone and time
b) Digital Channels display bug with >5M memory

Created with Pixso.
Descargar Created with Pixso.
SDL1000X actualización de firmware
Versión: V1.1.1.22
Fecha de actualización: 15/03/2026
Actualizaciones

1. Modify the EEROM model software matching upgrade;

Created with Pixso.
Descargar Created with Pixso.
SPS5000X actualización de firmware
Versión: V3.1.1.8R1
Fecha de actualización: 15/03/2026
Actualizaciones

1.Modify the EEROM model software matching upgrade.

Created with Pixso.
Descargar Created with Pixso.
SDG800 actualización de firmware
Versión: V1.08.01.15R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed the bug that startup occasional failures
2. Fixed the bug of burst sync output exception
3. Fixed the bug that may not output when switch
the waveform after the burst is turn off

Created with Pixso.
Descargar Created with Pixso.
SPD3303X actualización de firmware
Versión: V1.01.01.03.10
Fecha de actualización: 15/03/2026
Actualizaciones

1.This firmware is only compatible with
hardware version V6.1.
2.The MCU has been changed to GD32F427.
Firmware versions 1.01.01.02.XXX cannot be
upgraded.

Created with Pixso.
Descargar Created with Pixso.
SSA3000X-R actualización de firmware
Versión: V3.2.2.5.1R1
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
• Optimize the Ref level and Att couple
• Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
• Add Cable Atten to correct cable loss in DTF Mode
• Add .trc file in EMI Mode
• Add .lic file auto scan
Solved Issues:
• Fix the false signals in density view in RTSA mode
• Fix pi/4 DPSK 和 pi/8 DPSK decode errors in MA mode
• Fix calibration error when port extension on in VNA mode
• Fix fft frequency error in narrow span in SA mode
• Fix trace avg calculation error in SA mode
• Fix the zero sweep type when fft in SA mode

Created with Pixso.
Descargar Created with Pixso.
SPS5000X actualización de firmware
Versión: V3.1.1.8
Fecha de actualización: 15/03/2026
Actualizaciones

1.Change some user interfaces and operation methods
2.SET key changes to V/I function in main windows.
3.Optimize some features in list’s setup/save/web menus .

Created with Pixso.
Descargar Created with Pixso.
SDS6000A actualización de firmware
Versión: 1.4.3.3
Fecha de actualización: 15/03/2026
Actualizaciones

Note: This release cannot be downgraded to former releases.
1. Math: added filter operator
2. Supported to save waveform as Memory traces, which store the raw
data instead of the screen data (as Ref does), and can be source of
Measure/Math etc.
3. Measure: improved the AIM limit from 1,000 to up to 65,000 (AIM limit:
the upper limit of horizontal parameters measure statistics in one
frame )
4. Optimized intensity display of math traces.
5. Added support for mouse wheel when using a mouse
6. Supported CP030 current probe (with LPA10 adapter)
7. Eye Diagram: 100Base-TX signal supported
8. Trigger: Pattern trigger strategy changed
9. Power Analysis:
a) Supported MOSFET SOA (Safe Operating Area)
b) Bigger table size
10. Fixed several bugs
a) Moving the traces by gestures may cause the scope to freeze
b) [Bode Plot]Vertical Ref.level manual setting is partially bad
c) [Measure]Track plot – not working well in general
d) [Power Analysis]Current harmonics forgets table/bar view
e) Waveform Capture Rate breakdown at 20 ns/div
f) Measurements skip buffers in history mode

Created with Pixso.
Descargar Created with Pixso.
SPD3000X-E actualización de firmware
Versión: V1.01.01.03.10
Fecha de actualización: 15/03/2026
Actualizaciones

1. This firmware only supports SPD3303X/X-E with hardware version 6.1

Note:
A、 Machines with hardware version V6.1 do not support rolling back to previous firmware versions
B、 Machines with hardware version
2. Released EasyPower (P20 version) that matches it

Created with Pixso.
Descargar Created with Pixso.
SDG6000X actualización de firmware
Versión: V6.01.01.36R3
Fecha de actualización: 15/03/2026
Actualizaciones
1. Control the IQ output amplitude to avoid distortion
2. 优化采用外部参考时钟时的相位噪声
3. Fixed bug in FM modulation on square waveform
4. Fixed bug that the output amplitude of square wave, pulse
wave and PRBS is smaller than the set value
5. Fixed bug that VPP was still displayed on the UI when
control the output amplitude in dBm by the SCPI
command
6. Fixed the problem of abnormal pulse output when
pressing output in burst mode
7. Resolve potential key and touch non response issues
8. Fixed the bug that 128QAM cannot be demodulated
Created with Pixso.
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.5.2R1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Measurement enhancement – Added setup/hold time: tsu@R, tsu@F,
th@R, th@F
2. Optimized UI
3. Added SCPI commands for Measure Cursors and clearing measure
items in Simple mode
4. Supported LXI (only with the Uboot-OS Version 5.4)
5. Supported time zone setting
6. Fixed several bugs
a) Webserver doesn’t show instrument UI if the scope reboot with a
wireless mouse connected
b) Incorrect “Recall”icon in the File Manager
c) Scope freezes with AWG enabled and measure cursor on rise
time
d) IP setting of AWG in Bode Plot not remembered after reboot
e) Network storage only works for SMB1.0
f) MEAS:SIMPle:ITEMsOVSN,ON does not work as expected
g) Roll time incorrect at 1ks/div and 20kpts
h) Raw data not consistent in x and sinx/x interpolation modes
i) Math: Dx parameter of Derivation cannot be increased by
universal control
j) Incorrect FFT sample rate

Created with Pixso.
Descargar Created with Pixso.
SPD3303C actualización de firmware
Versión: V1.02.01.01.03R10
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SSA3000X Plus actualización de firmware
Versión: V3.2.2.5.1R1
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
• Optimize the Ref level and Att couple
• Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
• Add .trc file in EMI Mode
• Add .lic file auto scan
Solved Issues:
• Fix pi/4 DPSK 和 pi/8 DPSK decode errors in MA mode
• Fix fft frequency error in narrow span in SA mode
• Fix trace avg calculation error in SA mode
• Fix the zero sweep type when fft in SA mode

Created with Pixso.
Descargar Created with Pixso.
SDS1004X-E actualización de firmware
Versión: V6.1.37R9
Fecha de actualización: 15/03/2026
Actualizaciones

Fixed the problem: The skew of the two ADCs is not
accuracy for hardware of 09 version (System Status shows
Hardware Version: 09-xx). The other hardware version has
no this problem.

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: V6.1.37R9
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed the problem: The skew of the two ADCs is not
accuracy for hardware of 09 version (System Status shows
Hardware Version: 09-xx). The other hardware version has
no this problem.

Created with Pixso.
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.9R12
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed several bugs of 1.3.9R10
a) Compatibility issue on 2-channel models
b) WebServer control issue

Created with Pixso.
Descargar Created with Pixso.
SSG5000A actualización de firmware
Versión: V2.1.1.3.1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add LXI functionality
2. Change FTP transmission to encrypted transmission
3. Fixed some bugs
d) Solved the problem of incorrect calculation of sweep points
when the starting frequency of the sweep list is greater than
the ending frequency
e) Resolve the issue of sometimes incorrect reference code
settings
f) Resolve the issue of unordered flatness list
g) Solve the problem of functional buttons not working in
certain situations

Created with Pixso.
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V0.9.7R2
Fecha de actualización: 15/03/2026
Actualizaciones
  1. Acquire: supported Fixed Sample Rate and Fixed Memory Depth
    modes
  2. Connectivity:
    1. Supported LXI
    2. Supported Network Storage
  3. Measure: improved the AIM limit from 1,000 to up to 25,000 (AIM limit: the upper limit of horizontal parameters measure statistics in one frame )
  4. Power Analysis: supported MOSFET SOA (Safe Operating Area)
  5. Channel:
    1. Two custom probe ratio options supported
    2. Supported CP030 current probe (with LPA10 adapter)
  6. UX: Added support for mouse wheel when using a mouse
  7. Optimized UI
  8. Remote Control: Supported to read sequence segments by WF
    command
  9. Optimized the Bode Plot
  10. Fixed several bugs
    a) Incorrect zoom trace in Roll mode (Stop)
    b) Bode Plot draw error (missing draw)
    c) Bode Plot zig-zag phase
  11. [Measure] Gating settings cannot be typed in
Created with Pixso.
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.9R10
Fecha de actualización: 15/03/2026
Actualizaciones

Compatible with new hardware (hardware version: 04-xx).
Note:

  1. This is a firmware compatible with new hardware. No feature or specification difference between it and 1.3.9R6. It’s not necessary to upgrade it from 1.3.9R6 to this release.
  2. This release cannot be downgraded to former releases.
Created with Pixso.
Descargar Created with Pixso.
SDS6000A actualización de firmware
Versión: 1.4.0.0
Fecha de actualización: 15/03/2026
Actualizaciones

1. Channel: two custom probe ratio options supported
2. Fixed several bugs
a) Bode Plot draw error (missing draw)
b) Bode Plot – Very slow, nearly stuck, with some signal levels
c) Counter – totalizer not showing all numbers
d) Counter (time period) shows incredible numbers

Created with Pixso.
Descargar Created with Pixso.
SPD1305X actualización de firmware
Versión: V2.1.1.9
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add OCP function (long press the “Fine” key to enter or exit OCP function)

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: V2 (Only For 4-Channel models)
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SSA3000X-R actualización de firmware
Versión: V3.2.2.5.0
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• Add Ext Trigger Delay from 0-10 seconds in SA Mode
• Add Limit in Log mag and Lin mag format; add calibration average; add s1p touchstone file save in VNA mode
Improvements:
• VNA sweep points up to 10001; Scale down to 0.001 in Smith chart;
• MA Filter type Nyquist change to Raised Cosine to align SCPI command; improve filter performance in low frequency
• EMI RBW/Step from 1 to 3
Solved Issues:
• SA: Fixed the difference between marker and peak and marker style; Center Freq error;Limit fail to stop error; Auto frequency error; In normalization, auto re-normalized after any setting changes
• VNA:Fixed Phase error; STA file saving error; CSA file loading error; S21 calibration error; Enhanced calibration error
• RTSA: Fixed continue peak preset error; freq step error
• EMI: Fixed frequency offset error; saving std lim path error
• Web browser: Fixed change IP error, Login error after changing password

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: V6.1.37R8
Fecha de actualización: 15/03/2026
Actualizaciones

4. Fixed the problem: very few SDS1xx4X-e stuck at self-
calibration
5. Be Compatible with a new VGA chip

Created with Pixso.
Descargar Created with Pixso.
SDS1004X-E actualización de firmware
Versión: V6.1.37R8
Fecha de actualización: 15/03/2026
Actualizaciones
  1. Fixed the problem: very few SDS1xx4X-e stuck at self-
    calibration
  2. Be Compatible with a new VGA chip
Created with Pixso.
Descargar Created with Pixso.
SPD1168X actualización de firmware
Versión: V2.1.1.9
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add OCP function (long press the “Fine” key to enter or exit OCP function)

Created with Pixso.
Descargar Created with Pixso.
SVA1000X actualización de firmware
Versión: V3.2.2.5.0
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.

New Functionality:

  • Added Ext Trigger Delay from 0-10 seconds in SA Mode
  • Added Limit in Log mag and Lin mag format;
  • Added calibration average;
  • Added s1p touchstone file save in VNA mode

Improvements:

  • VNA sweep points up to 10001; Scale down to 0.001 in Smith chart;
  • MA Filter type Nyquist change to Raised Cosine to align SCPI command; improve filter performance in low frequency
  • EMI RBW/Step from 1 to 3

Solved Issues:

  • SA mode:

Fixed the difference between marker and peak and marker style;
Fixed Center Freq error; Fix limit fail to stop error;
Fixed Auto frequency error;
Fixed In normalization, auto re-normalized after any setting changes

  • VNA mode:

Fixed Phase error;
Fixed STA file saving error;
Fixed CSA file loading error;
Fixed S21 calibration error;
Fixed Enhanced calibration error

  • EMI mode:

Fixed Frequency offset error;
Fixed Saving std lim path error

  • Web browser cannot change IP, and cannot login after changing password
Created with Pixso.
Descargar Created with Pixso.
SVA1000X actualización de firmware
Versión: V3.2.2.5.1R1
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
⚫ Optimize the Ref level and Att couple
⚫ Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
⚫ Add Cable Atten to correct cable loss in DTF Mode
⚫ Add .trc file in EMI Mode
⚫ Add .lic file auto scan
Solved Issues:
⚫ Fix pi/4 DPSK 和 pi/8 DPSK decode errors in MA mode
⚫ Fix calibration error when port extension on in VNA mode
⚫ Fix fft frequency error in narrow span in SA mode
⚫ Fix trace avg calculation error in SA mode
⚫ Fix the zero sweep type when fft in SA mode

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: SDS1xx4X-E Firmware (4-Channel Models) – 6.1.37R6
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed the bug in 6.1.37R2 which cause the WiFi does not
work

Created with Pixso.
Descargar Created with Pixso.
SSA3000X Plus actualización de firmware
Versión: V3.2.2.5.0
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• Add Ext Trigger Delay from 0-10 seconds in SA Mode
Solved Issues:
• SA fix the difference between marker and peak and marker style; Fix Center Freq error; Fix
limit fail to stop error; Fix Auto frequency error; In normalization, auto re-normalized after any
setting changes
• EMI frequency offset error; saving std lim path error
• Web browser cannot change IP, and cannot login after changing password

Created with Pixso.
Descargar Created with Pixso.
SDS6000A actualización de firmware
Versión: V1.3.9.0
Fecha de actualización: 15/03/2026
Actualizaciones

1. Added English help
2. Added SCPI commands for network storage

Created with Pixso.
Descargar Created with Pixso.
SDS1004X-E actualización de firmware
Versión: V6.1.37R6
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed the bug in 6.1.37R2 which cause the WiFi does not
work

Created with Pixso.
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V0.9.5R3
Fecha de actualización: 15/03/2026
Actualizaciones
  1. Supported CAN-H, CAN-L as decode sources
  2. Fixed several bugs
    a) Unexpected skew between channels after Stop in Roll mode
    b) Some trigger setting with dual-level may lead the scope not to
    start-up properly
Created with Pixso.
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.9R6
Fecha de actualización: 15/03/2026
Actualizaciones

Fixed several bugs
a) When selecting the option screen the scope hangs
b) Wrong FFT frequency when memory depth > 10 Mpts
c) Incorrect network storage path leads the scope to hang

Created with Pixso.
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.9R4
Fecha de actualización: 15/03/2026
Actualizaciones
  1. 1. Measurement enhancement:
    1. a) Supported cursors for measurement
    2. b) Supported Track plot
    3. c) Added parameters: Positive Slope and Negative Slope
  2. 2. Display:
    1. a) Supported to display axis label
    2. b) Auto hide menu setting increased to 10 seconds
      c) Added “Hide” button in the fast menu of channel for quickly hiding
      trace
  3. 3. Save/Recall:
    1. a) Supported network storage
    2. b) Supported to Print only grid area
    3. c) Supported to save FFT result
    4. d) Updated the File Manager
  4. 4. Bode Plot:
    1. a) The maximum generator amplitude changed from 6Vp-p to
      24Vp-p
    2. b) Supported single sweep
  5. 5. Horizontal: Time Zero strategy updated – time zero changed from
    center display to trigger position.
  6. 6. Acquisition: Deleted some unnecessary clear operations on the history
    buffer
  7. 7. Updated Russian menu
  8. 8. Supported setting Cursors by virtual keypad
  9. 9. Fixed several bugs
    a) Decode failure occurs on last nibble or byte
    b) The “STL?” query issue in AWG function
    c) If persistence is enabled, and you change the trigger setting,
    persistence will be switched off
    d) Decode list can’t go higher than item #2
    e) Decode format is reset to “binary” when recalling stored settings
    f) Sequence capture does not work with serial trigger from digital
    channel
    g) ERES 0.5-bit works for ERES(C1), but not for ERES(F1)
    h) The icons for rise and fall time in the Measure Select screen are
    reversed
    i) When switching the attenuator, the message “Zone is too small”
    appears
    j) After shutting-down the scope and rebooting not all settings are
    restored
    k) Bode plot abnormal when Sequence is enabled
    l) SENT decode: tolerance not functional
    m) SENT decode: only display CRC segment but no calculation on
    the CRC checksum
    n) SENT decode: The Short Serial data is NOT decoded if only 16
    frames are sent. If a 17th frame follows, the data is decoded
    o) SENT decode: Changing the horizontal time/div affects the ability
    to decode.
    p) Save/recall: Number of digits of time stamp is not enough in the
    long period
    q) Infinite persistence not works after switching between 8-bit and
    10-bit
    r) Tolerance of UART decode too strict
    s) FFT max. scale is unrealistic
Created with Pixso.
Descargar Created with Pixso.
SDS1004X-E actualización de firmware
Versión: V6.1.37R2
Fecha de actualización: 15/03/2026
Actualizaciones
  1. 1. Added data logger featuring Sample and Measurement
    Logger functions
  2. 2. Added counter function
  3. 3. Added Labels
  4. 4. Added NTP (Network Time Protocol) and Time Zone. Also
    requires OS update to SDS1xx4X-E_OSV2 which is located
    on the SIGLENT product webpage. The OS Update
    Instructions is also included SDS1xx4X-E_OSV2.zip
  5. 5. Modified negative or positive of horizontal delay: Time
    zero is in trigger. Before trigger, time position is -time
    (negative delay relative to trigger) and after trigger is
    +time (positive delay relative to trigger)
  6. 6. Fixed a bug with Bin2CSV for ROLL mode
  7. 7. Rebuilt Bin2CSV to File Converter which can also convert
    data logger file to CSV.
  8. 8. Fixed a bug: some case there is a blue line on decode bus
  9. 9. Fixed a bug with saving hex MSO CSV file
  10. 10. Fixed a bug: After rebooting , Bode Plot cursor can’t be
    moved
  11. 11. Fixed a bug: fine adjusting with customer probe
  12. 12. WiFi supported Spaces and Special Characters
Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 6.1.37R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Added data logger featuring Sample and Measurement
Logger functions
2. Added counter function
3. Added Labels
4. Added NTP (Network Time Protocol) and Time Zone. Also
requires OS update to SDS1xx4X-E_OSV2 which is located
on the SIGLENT product webpage. The OS Update
Instructions is also included SDS1xx4X-E_OSV2.zip
5. Modified negative or positive of horizontal delay: Time
zero is in trigger. Before trigger, time position is -time
(negative delay relative to trigger) and after trigger is
+time (positive delay relative to trigger)
6. Fixed a bug with Bin2CSV for ROLL mode
7. Rebuilt Bin2CSV to File Converter which can also convert
data logger file to CSV.
8. Fixed a bug: some case there is a blue line on decode bus
9. Fixed a bug with saving hex MSO CSV file
10. Fixed a bug: After rebooting , Bode Plot cursor can’t be
moved
11. Fixed a bug: fine adjusting with customer probe
12. WiFi supported Spaces and Special Characters

Created with Pixso.
Descargar Created with Pixso.
SPS5000X actualización de firmware
Versión: V3.1.1.6
Fecha de actualización: 15/03/2026
Actualizaciones

1.First released version

Created with Pixso.
Descargar Created with Pixso.
SSA3000X actualización de firmware
Versión: V1.3.9.8
Fecha de actualización: 15/03/2026
Actualizaciones

1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Update the measurement result of MARKER immediately when changing its
parameters, instead of after the trace sweep ends.
3. Improve the stability of TG

Created with Pixso.
Descargar Created with Pixso.
SDM3065X actualización de firmware
Versión: V3.01.01.10
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add the scan card setup save&recall function.
2. Optimize the slot time of the channel switching of scan card.
3. Optimize flash R&W design.
4. Fix some UI & SCPI bugs.

Created with Pixso.
Descargar Created with Pixso.
SDS1000CML+actualización de firmware
Versión: V6.01.01.22
Fecha de actualización: 15/03/2026
Actualizaciones

Compatible with new hardware

Created with Pixso.
Descargar Created with Pixso.
SDM3055 actualización de firmware
Versión: V1.01.01.25
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add the scan card setup save&rcall function.
2. Optimize the slot time of the channel switching of scan card.
3. Optimize flash R&W design.
4. Fix some UI & SCPI bugs.

Created with Pixso.
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V0.9.5R2
Fecha de actualización: 15/03/2026
Actualizaciones

Fixed a bug which may cause failure on installation of option key in 0.9.5R1.

Created with Pixso.
Descargar Created with Pixso.
SDL1000X actualización de firmware
Versión: V1.1.1.21R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fix bug: DHCP turn to be ON state after send *RST command.
2. Some units will crash after run for some time.

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-U actualización de firmware
Versión: V1.1.5R6
Fecha de actualización: 15/03/2026
Actualizaciones

Support EasyScopeX(From V100R001B02D01P21)

Created with Pixso.
Descargar Created with Pixso.
SPD3303X-E actualización de firmware
Versión: V1.01.01.02.07R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add the OCP function (Long push “Fine”
to enter or exit OCP function).
2. The MCU is STM32.

Created with Pixso.
Descargar Created with Pixso.
SSA3000X actualización de firmware
Versión: V1.3.9.7
Fecha de actualización: 15/03/2026
Actualizaciones

1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
2. Fixed the LOG scale sweep time and display error
3. Fixed the trace file .trc load and display error
4. Improve the stability of TG
5. Add peak excursion require command:CALCulate:MARKer:PEAK:EXCursion?
Add sweep state require command:TRACe:SWEep:STATe?
Add N dB Bandwidth left and right frequency require command
:CALCulate:MARKer*:BANDwidth:RLEFt?
:CALCulate:MARKer*:BANDwidth:RRIGht?

Created with Pixso.
Descargar Created with Pixso.
SPD3303X actualización de firmware
Versión: 1.01.01.02.07R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add the OCP function (Long push “Fine”
to enter or exit OCP function).
2. The MCU is STM32.

Created with Pixso.
Descargar Created with Pixso.
SDM3055 actualización de firmware
Versión: V1.01.01.22R1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fix some unit faults of 22version.
2. Fixed some bugs about communication with easysdm

Created with Pixso.
Descargar Created with Pixso.
SDM3065X actualización de firmware
Versión: V3.01.01.08R1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed some crash fault about U disk save &recall.
2. Fixed some bugs about “acquire” function.
3. Improve the trend display function.
4. Fixed some bugs about communication with easysdm

Created with Pixso.
Descargar Created with Pixso.
SSA3015X Plus actualización de firmware
Versión: V3.2.2.4.0
Fecha de actualización: 15/03/2026
Actualizaciones

This version con not be rolled back
• Fix TG switch error at small RBW
• Fix Help and Limit file lost when Factory reset
• Fix CNR calc error when no peak found
• Fix OBW result overflow
• Fix Harmonic calc error at 100Hz RBW
• Fix Reflection Open+Short calibration action
• Fix spectrum amplitude error in DMA mode
• Optimize EMI .csv file content to all signal list
• Optimize EMI peak search
• Optimize Auto cal process
• Add Peak search to Spectrum in DMA mode

Created with Pixso.
Descargar Created with Pixso.
SVA1015X actualización de firmware
Versión: V3.2.2.4.0R2
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SVA1032X actualización de firmware
Versión: V3.2.2.4.0
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SVA1075X actualización de firmware
Versión: V3.2.2.4.0R2
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V2.1.1.1.12a or later. If your SVA1000X has an earlier
version, please update to V2.1.1.1.12a first and then proceed to update to the latest version.
⚫ Fix the VNA option license error on some SVA1015 and SVA1075 units

Created with Pixso.
Descargar Created with Pixso.
SSA3015X Plus actualización de firmware
Versión: V3.2.2.3.3R1
Fecha de actualización: 15/03/2026
Actualizaciones

New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue

Created with Pixso.
Descargar Created with Pixso.
SSA3000X-R actualización de firmware
Versión: V3.2.2.3.3R1
Fecha de actualización: 15/03/2026
Actualizaciones

New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the response in RTSA
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix ADC overload warning error, and time unit error in Calibration in VNA Mode
• Fix amplitude error in DMA Mode
• Fix the frequency band downgrade to 3.2GHz on some units
Fix upgrade failure issue

Created with Pixso.
Descargar Created with Pixso.
SVA1075X actualización de firmware
Versión: V3.2.2.3.3R1
Fecha de actualización: 15/03/2026
Actualizaciones

Notice:
This firmware must be upgraded from V2.1.1.1.12a or later. If your SVA1000X has an earlier
version, please update to V2.1.1.1.12a first and then proceed to update to the latest version.
New Functionality:
⚫ Add EMI filter in SA for EMI option
Solved Issues:
⚫ Optimize the TG flatness and control procedure
⚫ Optimize Help
⚫ Fix Correction, .csv file, add peak numbers to 20 in EMI mode
⚫ Fix ADC overload warning error, and time unit error in Calibration in VNA Mode
⚫ Fix amplitude error in DMA Mode
Fix upgrade failure issue

Created with Pixso.
Descargar Created with Pixso.
SVA1032X actualización de firmware
Versión: V3.2.2.3.3R1
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SVA1015X actualización de firmware
Versión: V3.2.2.3.3R1
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.7R5
Fecha de actualización: 15/03/2026
Actualizaciones

1. New serial protocols supported (optional):
a) SENT, trigger & decode
b) Manchester, decode only
2. Measurement enhancement:
a) Supported user-defined thresholds (Upper, Middle and Lower):
Measure | Config | Threshold
b) Added items: +Area@AC, -Area@AC, Area@AC, AbsArea@AC
3. Math: added new operator – Interpolate
4. Display:
a) Supported selectable color for traces: Display | Color Setting
b) Supported floating menu so that the waveform is not compressed
horizontally when the right-side menu is displayed: Display | Menu
Style
c) Supported to show bandwidth information on the channel
descriptor box
5. Save/Recall:
a) Added option “Save all channel” for csv file
b) Supported to save math traces (except FFT)
6. Bode Plot:
a) Optimized scan speed
b) Fixed unexpected glitch issue
7. Supported serial trigger as source of the frequency counter
8. Unlocked zoom in stop mode for Roll
9. Supported trigger Default or AutoSetup operations by pressing
corresponding button twice

10. Fixed several bugs
a) Some vertical measurement error in roll mode
b) Missed peak marker in FFT two-tone test
c) AWG problem of importing the arb file from a U-disk
d) Whenever the screen is touched, the pass/fail statistics is reset to
zero
e) SPI data value setting issue using virtual keypad
11. Compatibility issue between WebServer and latest Chrome/Edge
browsers

Created with Pixso.
Descargar Created with Pixso.
SPD3000C actualización de firmware
Versión: V1.02.01.01.03R6
Fecha de actualización: 15/03/2026
Actualizaciones

1. Buzzer abnormal sound
2. Limit: Two channel series voltage less than 60V
3. After recalling the settings, turn off the device without saving

Created with Pixso.
Descargar Created with Pixso.
SSA3000X actualización de firmware
Versión: V1.3.9.6
Fecha de actualización: 15/03/2026
Actualizaciones

1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
2. Fixed the problem unit in TG and the UNCAL condition
3. Fixed the AVG detector in frequency LOG scale
4. Fixed the display error with long file name
5. Fixed some SCPI commands
6. Fixed the beeper switch
7. Fixed the .cor file error when recalling it
8. Add Limit mask offset in frequency and amplitude

Created with Pixso.
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V0.9.3R3
Fecha de actualización: 15/03/2026
Actualizaciones
  1. Expanded the offset range
  2. New serial protocols supported (optional):
    1. SENT, trigger & decode
    2. Manchester, decode only
  3. Measurement enhancement:
    1. Supported user-defined thresholds (Upper, Middle and Lower): Measure | Config | Threshold
    2. Added items: +Area@AC, -Area@AC, Area@AC, AbsArea@AC
  4. Math:
    1. Added new operator – Interpolate
    2. Added function expression information to the math descriptor box
  5. Display:
    1. Supported selectable color for traces: Display | Color Setting
    2. Supported floating menu so that the waveform is not compressed horizontally when the right-side menu is displayed: Display | Menu Style
    3. Supported to hide analog traces
  6. Save/Recall:
    1. Added option “Save all channel” for csv file
    2. Supported to save math traces (except FFT)
  7. Supported serial trigger as source of the frequency counter
  8. Supported LeCroy probes ZD1000/ZD1500 with LPA10 probe adapter; supported Tek TekProbe interface level II probes with TPA10 probe adapter

Added button to reset remote password: Utility | System Setting | I/O | Web

Created with Pixso.
Descargar Created with Pixso.
SSA3015X Plus actualización de firmware
Versión: V3.2.2.3.2
Fecha de actualización: 15/03/2026
Actualizaciones

Solved Issues:
• Fix avg power bug in EMI Mode
• Fix amplitude bug in AMA Mode
• Fix peak search bug in SCPI command

Created with Pixso.
Descargar Created with Pixso.
SVA1032X actualización de firmware
Versión: V3.2.2.3.2
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.5R5
Fecha de actualización: 15/03/2026
Actualizaciones

1. Supported to hide analog traces
2. Added function expression information to the math box
3. Optimized AWG DC output accuracy at +/-3V
4. Frequency counter supported to count serial trigger events
5. Fixed several bugs
a) Incorrect cursor horizontal label for FFT traces
b) 2-channel 100MHz model cannot be upgraded to 350MHz
c) FRFR measure invalid from Roll to Stop
d) Unexpected behaviors when probe attenuation factor is not 1x
e) Some bugs in PA

Created with Pixso.
Descargar Created with Pixso.
SDL1000X actualización de firmware
Versión: V1.1.1.21
Fecha de actualización: 15/03/2026
Actualizaciones

1. The software version adds socket functionality and support for EasySDL.

Created with Pixso.
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.5R10
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed a bug that a firmware upgrade kills the scope if a previous
upgrade from the WebServer was failed.

Created with Pixso.
Descargar Created with Pixso.
SVA1032X actualización de firmware
Versión: V2.2.1.2.8
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SVA1015X actualización de firmware
Versión: V2.2.1.2.8
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDM3065X actualización de firmware
Versión: V3.01.01.07
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V0.9.1B2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed the bug the attenuation factor is not correct for the SAP1000 probe

Created with Pixso.
Descargar Created with Pixso.
SDS2000X Plus actualización de firmware
Versión: V1.3.5R3
Fecha de actualización: 15/03/2026
Actualizaciones

1. Supported Sign as a math function
2. Updated the Webserver. The built-in bin2csv tool supported to convert
binary data of digital channels
3. Added English help information
4. Fixed several bugs

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 6.1.35R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Added support for the SAG1021I USB Isolated AWG
Module Hardware
2. Fixed the bug: Sometimes PNSU command returns invalid
value (Need referring to the latest Program Guide)
3. Added 9 data bits for UART decoding
4. Fixed the bug of UART decoder with some special
settings

5. Increased baud rate of UART trigger from 5 Mbps to 20
Mbps
6. Fixed the bug: The command ‘WF? DAT2’returns error
length of waveform when digital is enable
7. Fixed the bug: CSV file of waveform has no indication of
the trigger point in the data
8. Fixed the bug: After repowering all FFT markers are on
just one peak
9. Fixed the bug: After repowering, signal level of CAN
trigger can’t be recalled
10. Fixed a few SCPI Commands errors:
MATH: CURSOR_VALUE?
C3:INVERT_SET? is missing
HISTORY_LIST? is missing
DIGITAL:LOW8_SWICHT, typo in name
C5:COUPLING? typo in name
11. Fixed the Bode Plot bug: Sometime there isn’t enough
delay after the scope switches timebase values before it
tries to take a measurement
12. Fixed the bug : Matlab can’t import 14 M Matlab
waveform files
13. Fixed the bug:‘WF?’command ignores the length set
by ‘WFSU’ for digital

Created with Pixso.
Descargar Created with Pixso.
SDS1004X-E actualización de firmware
Versión: V6.1.35R2
Fecha de actualización: 15/03/2026
Actualizaciones
  1. 1. Added support for the SAG1021I USB Isolated AWG
    Module Hardware
  2. 2. Fixed the bug: Sometimes PNSU command returns invalid
    value (Need referring to the latest Program Guide)
  3. 3. Added 9 data bits for UART decoding
  4. 4. Fixed the bug of UART decoder with some special
    settings
  5. 5. Increased baud rate of UART trigger from 5 Mbps to 20
    Mbps
  6. 6. Fixed the bug: The command ‘WF? DAT2’returns error
    length of waveform when digital is enable
  7. 7. Fixed the bug: CSV file of waveform has no indication of
    the trigger point in the data
  8. 8. Fixed the bug: After repowering all FFT markers are on
    just one peak
  9. 9. Fixed the bug: After repowering, signal level of CAN
    trigger can’t be recalled
  10. Fixed a few SCPI Commands error——MATH: CURSOR_VALUE?
    C3:INVERT_SET? is missing
    HISTORY_LIST? is missing
    DIGITAL:LOW8_SWICHT, typo in name
    C5:COUPLING? typo in name
  11. 11. Fixed the Bode Plot bug: Sometime there isn’t enough
    delay after the scope switches timebase values before it
    tries to take a measurement
  12. 12. Fixed the bug : Matlab can’t import 14 M Matlab
    waveform files
  13. 13. Fixed the bug:‘WF?’command ignores the length set
    by ‘WFSU’ for digital
Created with Pixso.
Descargar Created with Pixso.
SVA1015X actualización de firmware
Versión: V2.2.1.2.5
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SVA1032X actualización de firmware
Versión: V2.2.1.2.5
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDM3055 actualización de firmware
Versión: V1.01.01.20R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Modify the PID of the DMM according the latest rules.
2. Bug fix: In the save function, When the file’s name is too long, the system will perhaps be crashed.

Created with Pixso.
Descargar Created with Pixso.
SDS5000X actualización de firmware
Versión: V0.8.7R1B1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Supported Power Analysis (optional) (Analysis | Power Analysis)
2. Supported Bode Plot (Analysis | Bode Plot)
3. Supported Totalizer (Analysis | Counter). Frequency and period
parameters are moved from DVM to Counter
4. Supported 2 math traces and formula editor
5. Optimized FFT
a) Optimized menu structure
b) Supported peak and marker (Math | FFT | Tools)
c) Supported setting max points (Math | FFT | Config)
6. Measurement enhanced
a) Optimized the UI. In the “Basic” tab the items can be customized
(long pressing an item to add to or delete from Basic tab)
b) Added items: Median, Cycle median, -Bwidth, Time@max,
Time@min, 20-80%Rise, 80-20%Fall, +Area, -Area, Area,
AbsArea, Cycles, Rising Edges, Falling Edges, Edges, PPulses,
Npulses
c) Supported statistics on maximum 12 parameters at the same time (M2);
d) Optimized measurement accuracy of Rise/fall
e) Supported Trend Plot of measurement items
7. Optimized UX of knobs
8. Set the default function of the universal knob as adjusting the trace
intensity
9. Optimized SPO display
10. Supported moving the location of the decode buses vertically
11. Supported single step back or forward in Navigator
12. Added bandwidth limit indicator below 2.45mV/div (1GHz,
500MHz)/1mV/div(350MHz
13. Supported Zone trigger in Sequence mode
14. Added entry for Zone trigger in the right side trigger menu
15. Mask Test: Supported failed history (Mask Test | Failure to History)
16. Increased frequency setting digits of the AWG from 3 to 7
17. After gesture control of the vertical gain, the v/div knob still is in the
mode that has been used before with the gesture controls.
18. UART/LIN decode/trigger: supported baud rate > 5Mb/s
19. Reference position: Added user defined delay
20. Optimized UI in Zoom mode
21. Deleted the SCPI command which can start Telnet
22. Supported tapping on zone/histogram region to open the
corresponding menu
23. Fixed several bugs

Created with Pixso.
Descargar Created with Pixso.
SDS1000CML+actualización de firmware
Versión: 6.01.01.21R2
Fecha de actualización: 15/03/2026
Actualizaciones

Optimize self-calibration for channels.

Created with Pixso.
Descargar Created with Pixso.
SVA1015X actualización de firmware
Versión: V2.2.1.2.1
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 1.3.26
Fecha de actualización: 15/03/2026
Actualizaciones

1. Added SCPI command to set up gated measurements
and return the data.
2. Customers can save the result of decode list table to a
CSV file.
3. Modified the color of FFT to match the trace selected.
4. There are some times of quick calibration during warming
up the SDS XE. Added a menu below Utility to disable the
quick calibration so that the sampling isn’t interrupted.
5. Created software that converts binary waveform data to
CSV. It can be downloaded from the embedded web
server on the scope.
6. Fixed the bug: “Screen Save” button on web page does
not work with some browsers.
7. Fixed the bug: The setting of Educational mode can’t be
saved after power off.
8. Fixed a bug with MSO decoding. and the SLA1016
firmware also needs to be updated to 8.1.11.
9. Fixed the bug: The binary block returned by the
WAVEFORM command contains the length of the block
in the “#9” header. This length is incorrect when the NP
option of the WFSU command is used; the header then
gives the memory depth instead of the actual size of the
block.
10. Fixed the bug of the scope response from the
WAVEFORM command prefixes the binary block with the
string “ALL,” even when “CHDR OFF” is used.
11. Added exiting the on-screen keyboard by OK button.

Created with Pixso.
Descargar Created with Pixso.
SPD1168X actualización de firmware
Versión: V2.1.1.8
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 1.3.23
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 6.1.26
Fecha de actualización: 15/03/2026
Actualizaciones

1. Added SCPI command to set up gated measurements
and return the data.
2. Customers can save the result of decode list table to a
CSV file.
3. Modified the color of FFT to match the trace selected.
4. There are some times of quick calibration during warming
up the SDS XE. Added a menu below Utility to disable the
quick calibration so that the sampling isn’t interrupted.

5. Created software that converts binary waveform data to
CSV. It can be downloaded from the embedded web
server on the scope.
6. Fixed the bug: “Screen Save” button on web page does
not work with some browsers.
7. Fixed the bug: The setting of Educational mode can’t be
saved after power off.
8. Fixed a bug with MSO decoding. and the SLA1016
firmware also needs to be updated to 8.1.11.
9. Fixed the bug: The binary block returned by the
WAVEFORM command contains the length of the block
in the “#9” header. This length is incorrect when the NP
option of the WFSU command is used; the header then
gives the memory depth instead of the actual size of the
block.
10. Fixed the bug of the scope response from the
WAVEFORM command prefixes the binary block with the
string “ALL,” even when “CHDR OFF” is used.
11. Added exiting the on-screen keyboard by OK button.

Created with Pixso.
Descargar Created with Pixso.
SPD1000X actualización de firmware
Versión: V2.01.01.06R1
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 1.3.17R1
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 6.1.12
Fecha de actualización: 15/03/2026
Actualizaciones

1. Initial formal release of SDS1xx4X-E

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: V1 (Only For 4-Channel models)
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SPD3303X actualización de firmware
Versión: V1.01.01.02.05
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDM3055 actualización de firmware
Versión: V1.01.01.19
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add U disk recovery function.
2. Modify Hold function arithmetic.
3. Add the telnet SCPI function; port is 5024 Example: telnet 192.168.0.10 5024
4. Repair the external trig problem.

Created with Pixso.
Descargar Created with Pixso.
SDM3065X actualización de firmware
Versión: V3.01.01.03
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add U disk recovery function
2. Add the update of the calibration data function
3. Fix the bug of a few abnormal DCV measurements when the input terminal is shorted
4. Repair the external trigger problem
5. Add the telnet SCPI function; port is 5024
Example: telnet 192.168.0.10 5024
6. FPGA optimization

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 6.1.20R1
Fecha de actualización: 15/03/2026
Actualizaciones

2. Added Bode Plot support for all of Siglent’ s SDG
instruments
3. Fixed a bug in 6.1.20 which maybe cause the signal
disappear after self-calibration for channels

Created with Pixso.
Descargar Created with Pixso.
SDS1000X-E actualización de firmware
Versión: 6.1.25R2
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed the bug: Once the acquisition is stopped, the scope
often can’t find search events in other channels.
2. Fixed the bug: In certain situations, the scope freezes
when the Auto Setup button is pressed.
3. Fixed the bug: The Pass/Fail mask is not correct at edge
of screen left and right.
4. Attenuation and invert indicator were added into the
channel tab.
5. Any arbitrary probe factor from 1e-6 to 1e6 can be set by
universal knob.
6. Got rid of suffix ‘A’ that stands for ‘Acknowledge’ from
I2C decode.
7. Fixed the bug: The dedicated window for long I2C data
sometime lose data at right edge.
8. Fixed the bug: The decoder sometimes does not show
any info.
9. Fixed the bug: After updating to the last firmware and OS
version, the remote panel/control interface can no longer
be connected.

Created with Pixso.
Descargar Created with Pixso.
SPD3303X-E actualización de firmware
Versión: V1.01.01.02.05
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SPD3303X-E actualización de firmware
Versión: V1.01.01.02.03
Fecha de actualización: 15/03/2026
Descargar Created with Pixso.
SDS1000DL+ Series actualización de firmware
Versión: 6.02.01.08
Fecha de actualización: 15/03/2026
Actualizaciones

1. Repaired bug causing Math error when trace is stopped in dot
display mode
2. Fixed ‘add measurement’ error in Polish language
3. Bug repaired when measuring frequency of 500 Hz, using
alternate trigger, and a time base of greater than 1 ms/div

Created with Pixso.
Descargar Created with Pixso.
SDS1000CML+actualización de firmware
Versión: 6.01.01.19
Fecha de actualización: 15/03/2026
Actualizaciones

1. Repaired bug causing Math error when trace is stopped in dot
display mode
2. Fixed ‘add measurement’ error in Polish language
3. Bug repaired when measuring frequency of 500 Hz, using
alternate trigger, and a time base of greater than 1 ms/div

Created with Pixso.
Descargar Created with Pixso.
SDS1000CML+actualización de firmware
Versión: 6.01.01.18
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed condition where wave trace departs from zero line while
there is offset
2. Fixed bug: Sample rate of zoom changed after STOP in dot
display mode
3. Fixed bug: All measurements on, select source on a disable
channel. Reboot the Scope, then the software hangs on the
boot screen
4. Adjusted keyboard scan method to optimize recognizing
keyboard value
5. Modified BMP from 24bit to 16bit while save/get BMP form
Scope

Created with Pixso.
Descargar Created with Pixso.
SDS1000DL+ Series actualización de firmware
Versión: 6.02.01.07
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed condition where wave trace departs from zero line while
there is offset
2. Fixed condition where wave trace departs from zero line while
there is offset
3. Fixed bug: All measurements on, select source on a disable
channel. Reboot the Scope, then the software hangs on the
boot screen
4. Adjusted keyboard scan method to optimize recognizing
keyboard value
5. Modified BMP from 24bit to 16bit while save/get BMP form
Scope
6. Fixed the bug: Wave trace disappear after STOP in scan
mode

Created with Pixso.
Descargar Created with Pixso.
SSA3000X actualización de firmware
Versión: V1.2.8.2
Fecha de actualización: 15/03/2026
Actualizaciones

1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Add socket/telnet-scpi, you can operate remote control through LAN port without
NI-VISA installed. Please see SSA3000X‘s Programming Guide for more details.
3. Change two limit lines in different colours.
4. When quit from TG, stay in“Auto” sweep.
5. Lower some spurs when FFT.
6. Improve the stability.

Created with Pixso.
Descargar Created with Pixso.
SSA3000X actualización de firmware
Versión: V1.2.8.1
Fecha de actualización: 15/03/2026
Actualizaciones

1. Add “PNG“ file type for screenshot.
2. Support TG in RBW less than 30 kHz.
3. Modify default TG output power, -20 dBm in spectrum ananlyzer mode and 0 dBm in
reflection measure mode, and some other TG issues.
4. Updating the format of “LIM“ file. After this firmware , the old limit files will not be
supported. You can recreate them through “EasySpectrum” free software easily.
5. After this firmware, do not support downgrade operation.

Created with Pixso.
Descargar Created with Pixso.
SSA3000X actualización de firmware
Versión: V1.2.7.3
Fecha de actualización: 15/03/2026
Actualizaciones

1. Fixed “button does not respond after self test”

Created with Pixso.
Descargar Created with Pixso.