SIGLENT Launches SMM3000X Series Source/Measure Unit

Visualizzazione 282

February 27, 2026 — SIGLENT Technologies releases SMM3000X Series Source/Measure Unit (SMU). SMM3000X features 6½-digit resolution, output capability of up to ±210 V DC voltage, ±3.03 A DC current, and ±10.5 A pulsed current, with programming and measurement resolution down to 10 fA / 100 nV, and a maximum acquisition rate of 100,000 points/s.

The SMM3000X supports four-quadrant operation, enabling simultaneous sourcing and measurement for closed-loop source–measure operations on DUTs. It can function as a voltage source, current source, voltmeter, ammeter, and ohmmeter, and also supports pulse generation and arbitrary waveform output, making it an ideal platform for characterizing semiconductors and other nonlinear devices and materials.


High-Accuracy Pulse Simulation

In pulse mode, the SMM3000X series supports pulsed current output up to ±10.5 A, with a minimum pulse width of 50 μs. This allows precise emulation of transient operating conditions of power devices, such as switching loss testing for GaN and SiC devices, providing strong support for R&D and validation of wide-bandgap power semiconductors.


Linear and Log Sweep Functions

The SMM3000X supports linear, log and pulsed sweep modes. Users can define start and stop values with fixed step sizes to source voltage or current point-by-point, while automatically measuring and logging each data point. This enables fast characterization of devices such as diodes and transistors, allowing engineers to extract I-V curves and analyze conduction behavior under different operating conditions.


Flexible User-Defined Sequences

List mode allows users to define custom output sequences with minimum timing resolution down to 10 μs. Parameter changes can be linear, non-linear, arbitrary, or user-ordered. The SMM3000X outputs voltage or current according to the defined list while synchronously measuring and recording data—ideal for non-uniform sweeps, multi-segment tests, and complex stimulus profiles.


Data Visualization and Analysis

The SMM3000X series provides multiple display modes including Graph, Roll, and Measure views.

  • Graph View enables real-time plotting of mathematical results.
  • Roll View displays time-domain waveforms of acquired data.
  • Measure View provides statistical analysis of traces.

These views offer multi-dimensional insight into test results, making data interpretation and debugging more intuitive.


Efficient Remote Programming and Control

Based on an advanced SCPI command set, the SMM3000X supports USB and LAN interfaces for seamless PC connectivity and automation. Users can operate the instrument via a built-in web interface or implement deep custom control using SCPI scripting. In addition, TCP/IP Socket communication is supported for flexible network-based test control and integration into automated test systems.

The SMM3000X series is designed to meet the precision testing needs of third-generation semiconductors, advanced optoelectronic devices, and emerging materials, while also significantly accelerating development cycles for new energy batteries and high-density integrated circuits. By improving both test efficiency and measurement accuracy, provides a powerful foundation for new product development and innovation.

Other

List of standard probes and other accessories for oscilloscopes

Visualizzazione 5
Application Notes

Gain Compression Measurements with the SNA Network Analyzer

Visualizzazione 5
Application Notes

Accurate Vector Mixer Measurements with a Vector Network Analyzer

Visualizzazione 5
Servizi e assistenza

Waveform appears but is not stable

Visualizzazione 5

3.1 Check that the trigger source channel is consistent with the waveform being viewed
3.2 Manually adjust the LEVEL trigger knob to see whether the waveform is stable.
3.3 Use AUTO to adjust the waveform automatically to determine whether the waveform is stable
3.4 Adjust time base, rule out false-wave interference (such as alias displayed waveforms)

Servizi e assistenza

The oscilloscope does not turn on

Visualizzazione 5

First, check the power cord and power strip for damage. Check the power switch on the instrument to make sure it is open (SDS1000CFL series has a power switch and a power protection switch). Is the power light illuminated?
Is the fan operating? If the fan works, the machine is powered on. If everything is normal but the oscilloscope still does not turn on, please contact your nearest SIGLENT dealer.

Servizi e assistenza

What does “div” mean in the specifications?

Visualizzazione 5

The term “div” for most SIGLENT specifications is equal to the Vertical Scale value (Commonly shown in units of Volts/div).
Take the specification for the DC Gain Accuracy of a SIGLENT SDS1052DL+
For ranges ≤ 100 mV/div, the DC Gain Accuracy is given as
± [3% × (|reading|+|offset|) +1% × |offset| +0.2 * div+2 mV]
If:
Reading = 0.5 V
Offset is 0.1 V
Vertical scale (div) = 100 mV/div = 0.1 V/div,
Then DC Gain is calculated as follows:
± [3% × (|reading|+|offset|) +1% × |offset| +0.2 * div+2 mV] =
± [3% × (|0.5 V|+|0.1 V|) +1% × |0.1 V| +0.2 div * (0.1 V/div) + 0.002 V] =
± [3% × (0.6 V) + 0.0001 V + 0.02 V + 0.002 V] = 0.018 V + 0.0001 V + 0.02 V + 0.002 V = 0.0401 V

Servizi e assistenza

Where do I find environmental, EMC, and other compliance information for your products?

Visualizzazione 5

Information regarding product compliance is available on the datasheet for each product.
Contact your local Siglent office for more details if you have trouble finding what you need.
You can also write sales@siglent.com

Servizi e assistenza

How to generate the activation code for an instrument option?

Visualizzazione 5

Many SIGLENT instruments feature options that can be added by using an activation code.
To generate the activation code:
– Purchase the option from your favorite SIGLENT office or distributor. A full list of available options are located at the bottom of the specific product web page.
– You will receive an Option Card PDF document from SIGLENT that contains important information for permanent activation of the features. Keep this information handy through the next steps.
– Go to http://service.siglenteu.com/easyweb/
-Enter the information from the Option Card in the correct fields of the webpage, and press Submit:

Servizi e assistenza

What is the maximum voltage for the external trigger inputs of the SDS1X/X+, SDS2X, and SDS1202XE os

Visualizzazione 5

The maximum safe voltage of ext trigger channel is 40 Vpp.
The specification of working voltages are:
Ext : ± 600 mVpp
Ext/5: ±3 Vpp.