| output |
150 V /30 A /200-300 W |
120 V/ 60 A/ 250 W |
| Operating Mode |
CC/CV/CP/CR |
CC/CV/CP/CR |
| CV Model Accuracy |
±(0.05% + 0.025%FS) |
±(0.05% + 0.025%FS) |
| CC Model Accuracy |
±(0.05% + 0.05%FS) |
±(0.05% + 0.1%FS) |
| CR Model Accuracy |
0.01% +0.0008 s |
0.01% +0.0008 s |
| CP Model Accuracy |
0.1% + 0.1%FS |
0.2% + 0.2%FS |
| Readback Resolution |
0.1 mV/0.1 mA |
0.1 mV/0.1 mA |
| Current Rise Time Range |
0.001 A/μs~2.5 A/μs |
0.001 A/μs~2.5 A/μs |
| Dynamic Mode Frequency |
25 kHz |
25 kHz |
| Protection Mode |
OCP, OVP, OPP, OTP and LRV protection |
OCP, OVP, OPP, OTP and LRV protection |
| Trend Chart |
Support |
Not support |
| Test Function |
Short-circuit, Battery test, CR-LED mode, and factory test functions |
Voltage rise/fall speed test, Battery test, CR-LED mode,OCP,OPP
|
| Voltage/Current Monitor |
Support |
Support current monitoring |
| Compensation Mode Function |
Support |
Not support |
| List Operation Function |
Support |
Support |
| Interface |
RS232/USB device/LAN/ USB-GPIB(option) |
GPIB、USB device、RS232 |
| Display |
3.5 inch TFT-LCD |
VFD |