{"id":68906,"date":"2025-09-18T14:24:49","date_gmt":"2025-09-18T06:24:49","guid":{"rendered":"https:\/\/www.siglent.com\/sdg6000x-firmware-update\/"},"modified":"2025-09-18T14:24:49","modified_gmt":"2025-09-18T06:24:49","slug":"sdg6000x-firmware-update","status":"publish","type":"post","link":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/","title":{"rendered":"SDG6000X Firmware Update"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"author":17,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[405,406,407,408],"tags":[],"class_list":["post-68906","post","type-post","status-publish","format-standard","hentry","category-service-support","category-resource","category-firmware-and-other","category-firmware"],"acf":{"pdf-file":null,"file-external-url":"","software-package":"https:\/\/siglent.oss-cn-shenzhen.aliyuncs.com\/English_content\/Firmware\/Signal_generator\/SDG6000X_V6.01.01.38R3_EN.zip","version":"V6.01.01.38R3","version-description":"1. Support IQ waveform generated by customIQ of\nSigIQPro;\n2. Screenshot files support PNG and BMP formats;\n3. MOD, SWEEP, BURST add RUN\/Stop control function;\n4. Support display of current output frequency during\nfrequency sweep;\n5. Fixed the bug that the waveform is discontinuous when\nthe length of the sequence wave is not an integer multiple\nof 16;\n6. Enhance the sequence function, and the number of loops\nof segment no longer occupies storage space multiple\ntimes;\n7. Delete the true arb mode of arb wave, and only keep the\nDDS mode. The true arb mode is implemented by the\nsequence (sequence with only one segment);\n8. Solve the problem of abnormal output when the frequency\nbetween 250MHZ and 300MHz during sweep;\n9. Modify the default output polynomial of PRBS and support\nprogrammable polynomial;\n10. Sync output supports 50% duty cycle output mode;\n11. IQ waveform information diaplay add data source\ninformation;\n12. Solve the problem of duty cycle is changed during\nfrequency change when square or pulse output;\n13. Added a new DC output mode to solve the problem that\nwhen changing the voltage, the output will jump to 0\nbefore outputting. This method will reduce the output\naccuracy;\n14. Support amplitude sweep function.","warning-text":"","product-category":["\u51fd\u6570\/\u4efb\u610f\u6ce2\u5f62\u53d1\u751f\u5668"],"product":["SDG6000X"]},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SDG6000X Firmware Update - Siglent Website<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SDG6000X Firmware Update - Siglent Website\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/\" \/>\n<meta property=\"og:site_name\" content=\"Siglent Website\" \/>\n<meta property=\"article:published_time\" content=\"2025-09-18T06:24:49+00:00\" \/>\n<meta name=\"author\" content=\"Zhou, Vera\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Zhou, Vera\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/\"},\"author\":{\"name\":\"Zhou, Vera\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#\\\/schema\\\/person\\\/c36fe2aa0ed92db0834fcb90b6c22a16\"},\"headline\":\"SDG6000X Firmware Update\",\"datePublished\":\"2025-09-18T06:24:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/\"},\"wordCount\":4,\"publisher\":{\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#organization\"},\"articleSection\":[\"Service &amp; Support\",\"Resource\",\"Firmware and Other\",\"Firmware\"],\"inLanguage\":\"en-MY\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/\",\"url\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/\",\"name\":\"SDG6000X Firmware Update - Siglent Website\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#website\"},\"datePublished\":\"2025-09-18T06:24:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/#breadcrumb\"},\"inLanguage\":\"en-MY\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/sdg6000x-firmware-update\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Service &amp; Support\",\"item\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/category\\\/service-support\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Resource\",\"item\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/category\\\/service-support\\\/resource\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Firmware and Other\",\"item\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/category\\\/service-support\\\/resource\\\/firmware-and-other\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Firmware\",\"item\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/category\\\/service-support\\\/resource\\\/firmware-and-other\\\/firmware\\\/\"},{\"@type\":\"ListItem\",\"position\":6,\"name\":\"SDG6000X Firmware Update\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#website\",\"url\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/\",\"name\":\"Siglent Website\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-MY\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#organization\",\"name\":\"Siglent Website\",\"url\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-MY\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.siglent.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/400X100-web-site2.png\",\"contentUrl\":\"https:\\\/\\\/www.siglent.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/400X100-web-site2.png\",\"width\":400,\"height\":100,\"caption\":\"Siglent Website\"},\"image\":{\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/#\\\/schema\\\/person\\\/c36fe2aa0ed92db0834fcb90b6c22a16\",\"name\":\"Zhou, Vera\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-MY\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f278126edcf9f56cc84d83ee9cced8e7137f686ce246233efeacf25d5d78d7e6?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f278126edcf9f56cc84d83ee9cced8e7137f686ce246233efeacf25d5d78d7e6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f278126edcf9f56cc84d83ee9cced8e7137f686ce246233efeacf25d5d78d7e6?s=96&d=mm&r=g\",\"caption\":\"Zhou, Vera\"},\"url\":\"https:\\\/\\\/www.siglent.com\\\/my\\\/author\\\/vera-zhou\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SDG6000X Firmware Update - Siglent Website","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/","og_locale":"en_US","og_type":"article","og_title":"SDG6000X Firmware Update - Siglent Website","og_url":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/","og_site_name":"Siglent Website","article_published_time":"2025-09-18T06:24:49+00:00","author":"Zhou, Vera","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Zhou, Vera"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/#article","isPartOf":{"@id":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/"},"author":{"name":"Zhou, Vera","@id":"https:\/\/www.siglent.com\/my\/#\/schema\/person\/c36fe2aa0ed92db0834fcb90b6c22a16"},"headline":"SDG6000X Firmware Update","datePublished":"2025-09-18T06:24:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/"},"wordCount":4,"publisher":{"@id":"https:\/\/www.siglent.com\/my\/#organization"},"articleSection":["Service &amp; Support","Resource","Firmware and Other","Firmware"],"inLanguage":"en-MY"},{"@type":"WebPage","@id":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/","url":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/","name":"SDG6000X Firmware Update - Siglent Website","isPartOf":{"@id":"https:\/\/www.siglent.com\/my\/#website"},"datePublished":"2025-09-18T06:24:49+00:00","breadcrumb":{"@id":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/#breadcrumb"},"inLanguage":"en-MY","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.siglent.com\/my\/sdg6000x-firmware-update\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.siglent.com\/my\/home\/"},{"@type":"ListItem","position":2,"name":"Service &amp; Support","item":"https:\/\/www.siglent.com\/my\/category\/service-support\/"},{"@type":"ListItem","position":3,"name":"Resource","item":"https:\/\/www.siglent.com\/my\/category\/service-support\/resource\/"},{"@type":"ListItem","position":4,"name":"Firmware and Other","item":"https:\/\/www.siglent.com\/my\/category\/service-support\/resource\/firmware-and-other\/"},{"@type":"ListItem","position":5,"name":"Firmware","item":"https:\/\/www.siglent.com\/my\/category\/service-support\/resource\/firmware-and-other\/firmware\/"},{"@type":"ListItem","position":6,"name":"SDG6000X Firmware Update"}]},{"@type":"WebSite","@id":"https:\/\/www.siglent.com\/my\/#website","url":"https:\/\/www.siglent.com\/my\/","name":"Siglent Website","description":"","publisher":{"@id":"https:\/\/www.siglent.com\/my\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.siglent.com\/my\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-MY"},{"@type":"Organization","@id":"https:\/\/www.siglent.com\/my\/#organization","name":"Siglent Website","url":"https:\/\/www.siglent.com\/my\/","logo":{"@type":"ImageObject","inLanguage":"en-MY","@id":"https:\/\/www.siglent.com\/my\/#\/schema\/logo\/image\/","url":"https:\/\/www.siglent.com\/wp-content\/uploads\/2025\/11\/400X100-web-site2.png","contentUrl":"https:\/\/www.siglent.com\/wp-content\/uploads\/2025\/11\/400X100-web-site2.png","width":400,"height":100,"caption":"Siglent Website"},"image":{"@id":"https:\/\/www.siglent.com\/my\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.siglent.com\/my\/#\/schema\/person\/c36fe2aa0ed92db0834fcb90b6c22a16","name":"Zhou, Vera","image":{"@type":"ImageObject","inLanguage":"en-MY","@id":"https:\/\/secure.gravatar.com\/avatar\/f278126edcf9f56cc84d83ee9cced8e7137f686ce246233efeacf25d5d78d7e6?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f278126edcf9f56cc84d83ee9cced8e7137f686ce246233efeacf25d5d78d7e6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f278126edcf9f56cc84d83ee9cced8e7137f686ce246233efeacf25d5d78d7e6?s=96&d=mm&r=g","caption":"Zhou, Vera"},"url":"https:\/\/www.siglent.com\/my\/author\/vera-zhou\/"}]}},"_links":{"self":[{"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/posts\/68906","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/comments?post=68906"}],"version-history":[{"count":0,"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/posts\/68906\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/media?parent=68906"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/categories?post=68906"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.siglent.com\/my\/wp-json\/wp\/v2\/tags?post=68906"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}