製品情報
SIGLENT SDG2000Xシリーズは、120MHzの出力周波数、最大8Mptsの任意波形長をサポート。高精度かつ高複雑度の波形生成要件に確実に対応します。
主な特徴
- デュアル出力チャンネル,最大120 MHzの出力周波数
- 1.2 GSa/s Sampling rate, 16 bit vertical resolution
- TrueArbテクノロジー、8 ~ 8 Mptsのメモリ長(任意波形)
- 低ジッタの矩形波とパルス,微調整可能なパルス幅と立ち上がり/立ち下がり時間設定
array(7) {
[17375]=>
string(56) "https://www.siglent.com/jp/products/oscilloscope/filter/"
[17384]=>
string(47) "https://www.siglent.com/jp/products/vna/filter/"
[17344]=>
string(61) "https://www.siglent.com/jp/products/spectrum_analyzer/filter/"
[11944]=>
string(56) "https://www.siglent.com/jp/products/rf-generator/filter/"
[11918]=>
string(57) "https://www.siglent.com/jp/products/arb_generator/filter/"
[17555]=>
string(56) "https://www.siglent.com/jp/products/power_supply/filter/"
[11998]=>
string(54) "https://www.siglent.com/jp/products/multimeter/filter/"
}
最高出力周波数
120 MHz
最大サンプリングレート
1.2 GSa/s
垂直軸分解能
16-bit
SDG2000Xは、高性能のデュアルチャンネルと高忠実度の信号出力を実現しています。
従来のDDS方式では、サンプリングレートと出力周波数の関係が整数倍でない場合、1サンプリング周期のジッタが発生しますが、EasyPulseテクノロジーはこの課題を完全に解決することができます。低ジッタの矩形波とパルスの出力に加え、以下のような利点があります。
· 最大150 MHzのパルス周波数
· 立ち上がり時間と立ち下がり時間を個別に最小1 nsまで調節可能
· パルス幅は最小3.2 nsまで微調節が可能
· 最小0.001%のデューティ比
· 低ジッタ
TrueArbテクノロジーは、従来のDDS方式よりも低ジッタかつ低歪みの出力が可能です。また、任意波形をポイントごとに出力する機能も備えています。 波形データを漏らすことなく出力できる他、次のような利点があります。
The SDG2000X can perform various kinds of modulations, sweeps, burst and signal synthesis. It supports internal, external and manual trigger sources.
| 比較に追加 | 型番 | 最高出力周波数 | 最大サンプリングレート | 垂直軸分解能 | 波形長 | チャネル数 | 価格 |
|---|
1. Supports webserver (0x6 version hardware); adds virtual panel in web control mode.
2. Screenshots support PNG file format.
3. Adds low-resolution output mode to DC output.
4. Sweep add step mode.
1. Added statistic function in counter mode
2. Supported using method 2 from our “generating
mulitphase waveforms” application note (refer to
http://www.siglentamerica.com/prodcut-pxzl.aspx?id=9
0&tid=16&T=2) to synchronize 2 units of SDG2000X
3. Fixed some bugs
a) A bug in file system could cause the generator
never startup
b) DHCP does not run at power up
c) Channel lock phase can be wrong in modulation
sometimes
d) Error in calculation of frequency deviation in
counter mode
e) Instrument does not allow CH1 and CH2 to both
use the external input for the modulation source
simultaneously in tracking mode
f) Downward compatibility of .xml state file
g) Unable to delete files with uncommon character(s)
in their names
1. Allow 0 Hz for CH Frequency In MOD Modes PM, AM,
DSB-AM, ASK, PSK
2. Allow MOD frequency > CH Frequency In MOD Modes
PM, DSB AM, ASK
3. Allow DSB-AM, AM MOD Modes In TrueArb Mode
4. Up Followed by Down Sweep Mode is Supported in
Linear Sweep (No Change for Log Sweep)
5. Added ARB waveform name to display, allowing user to
know what Arb waveform is loaded
6. Fixed some bugs
a) Arb Waveforms In DDS Mode Have One (Small)
Glitch Per Cycle
b) Built in Ramp waveform has a flat spot issue at the
rising slope zero crossing right at the SYNC pulse.
c) Power Up Last Does Not Remember
SRate/Frequency Setting
d) MOD Type = DSB AM Has Amplitude Issues
1. Supported system recovery from U-disk.
2. Fixed a bug which may cause the generator report a
false over voltage alarm when start-up.
Optimized calibration and PV process on the production line.
1. Changed the amplitude strategy of AM modulation: The
carrier stays fixed at the amplitude, regardless of the
modulation setting.
2. Increased the upper limit of Harmonics number from 10
to 16.
3. Supported Multi-Device Synchronization.
4. Supported Up followed by Down Sweep mode in Linear
sweep (no change for Log sweep).
5. Added an icon to indicate clock source is internal or
external.
Internal: External:
External and the clock is lost:
6. Changed the clock switch strategy: When the clock
source is set to External and no actual external clock
signal is being received, the clock source will not switch
to Internal automatically but the clock icon will
indicate that external clock is lost
7. Supported specifying Arb type by remote control when
the modulating waveform is Arb.
8. Optimized the UI of selecting built-in arbs
9. Supported changing the unit of amplitude without any
amplitude change by long pressing the “Amplitude”
softkey.
10. Added “User” option under “PowerOn Setting”.
11. Added “Normal” as a new UI color style.
12. Added memory space information in Store/Recall UI.
13. Optimized response of the universal knob
14. Added indicator for double function of the soft keys
=>
15. Removed the warning message when parameter is set
to a value beyond the limit
16. Fixed several bugs
a) [2017/04/07-92573] Digit changes when setting
delay of Pulse by the knob
b) Amplitude unit “dBm” is not remembered after a
reboot
Optimized debounce of the front panel buttons.
1. Compatible with Rev.F hardware
2. Support trig dual channel separated when use mannul
trigger.
3. Support using another channel as the modulation
source
4. Support setting the output frequency after the
completion of sweep
5. Counter add fast measurement mode
6. Change the square waveform data used in square FM
modulation
USB-AからUSB-B。装置とPCを接続して通信するために使用します。
装置には、ユーザーの国の規格に合致した電源コードが1本標準で付属しています。異なる地域用の追加の電源コードは別途購入できます。
デュアルBNCコネクタ同軸ケーブル
装置標準のクイック使用ガイドです。
装置のUSBインターフェイスをGPIBインターフェイスに変換します。GPIBコマンドを使用することで、さまざまな操作タスクをより容易に実行できます。USBインターフェイスはUSB 2.0規格に準拠し、GPIBインターフェイスはIEEE 488.2規格に準拠しています。
