- Product Center
- Solution
- Service & Support
- About SIGLENT
1. Supports RE model.
2. Solve the problem of inaccurate measurement values under the 200V range of DCV.
3. Bug fixes
a) Restore the default trigger source error under Cont function.
b) Opening the statistics menu causes the probehold menu to disappear.
c) Optimize the prompt window under the Data Log menu and the trend chart display issue.
d) When the Power On mode is Last, the switch between the temp and cont functions is abnormal.
e) The number of sampling points exceeds 2M and the timestamp is incorrect.
f) When the trigger source is an external trigger, the trigger status changes to automatic after the abort instruction.
g) Support the transmission of scanner card data timestamps.
h) Setting the Socket parameter to MAX causes the system to freeze.
i) Remotely enable relative values, send *RST, and switch to local trigger without reading.
j) The sampling interval of the Data Log cannot be set to 3600s.
k) When the DCI range is switched, the range obtained by the instruction is inconsistent with the UI.
Features and Enhancements:
Bug Fixes:
Features and Enhancements:
1. Added harmonic analysis measurement function in SA measurement mode.
2. Added full-channel calibration function.
3. Added calibration information display function.
4. Added power compensation function for fixture simulation.
5. Added ECal (Electronic Calibration) characterization function.
6. Added Compression Point Search / Saturation Point Search / Normal Operating Point Search functions.
7. Added Preferences settings.
8. TDR Measurement Mode: Now supports extended port function.
9. AFR (Automatic Fixture Removal): Now supports timedomain trace display.
10. Minimum Sweep Points: Now supports a minimum setting of 1 point.
11. File Manager: Added support for “Favorites” and “History” functions.
12. Power Meter: Added support for IP connection.
13. Power Meter Reading: Default frequency changed to 50 MHz.
14. Switch Matrix: Added support for characterization and deembedding functions.
Bug Fixes:
1. Fixed the issue where single-ended measurements (e.g., Sss11) would not sweep under balanced measurement mode.
2. Fixed the issue where smoothing results were abnormal under the Phase format.
3. Fixed the issue where traces might appear abnormal after executing a calibration data overwrite.
4. Fixed the issue where the power calibration progress bar might display incorrectly.
5. Fixed the issue where trace data became abnormal after recalling CSV files saved from Power Sweeps or CW Sweeps.
6. Fixed the issue where the sweep would hang when the external trigger signal frequency was high in “Point Trigger” mode.
7. Fixed the issue where the log display time might be incorrect.
8. Fixed abnormal UI control behavior in the SA measurement mode configuration dialog.
9. Fixed the issue where eye diagram data might be abnormal after modifying the rise time in TDR measurement mode.
1.Optimized Multitone function
2.AWG Added single waveform setting UI
3.Resolved an issue where the UI would occasionally fail to display during startup.
4.Resolved an issue where startup would occasionally fail.
5.Fixed an output error when manually triggering in IQ mode.
Features and Enhancements:
Bug Fixes:
Features and Enhancements:
Bug Fixes:
1. Optimized UI response in the case of long waveform depth
2. Added Spectrum Analysis mode
3.Channel: in Eres mode to display the corresponding bandwidth information in the descriptor box
4.Decode: Added SPMI, Spacewire, 8B/10B, MIPI-RFFE
5.Measure:
a)Added item: Bit Rate, Data rate, △TimeMax, △TimeMin
b)Supported to limit the display digits of measure
6.Memory: Supported to import a file with data of multi-channel
7.Analysis:
a)Eye /Jitter upgraded to 2.0: optimized UI; added explicit clock; supported Equalization; supported Noise analysis; supported differential source; supported F1-F4, M1-M4 as source
b)Compliance Test: added 10BASE-T, 10BASE-T1S, DDR4, PCIe 1.0/2.0
c)Serial Signal Test: added I2C, SPI
d)Bode plot: added crossover frequency measure
8. Probe: Supported SAP8000D probe
9.Roll:
a)Supported Math and track cursors in Stop mode
b)Supported bandwidth limit
10.Webserver: supported inverted screenshot (according to the Image style setting in the Save menu)
11.Save/recall: File Manager: Supported to Select All; Supported to save all frames to a single file in Sequence mode
12.UI:Supported to specify Zoom region by drag a rectangle
13.Utility:Added English help; Supported password for screen saver
14. Fixed several bugs
a) When Log horizontal is used in FFT numbers are scrambled
b) Vertical axis of FFT optimized
c) Grid not aligned with numbers/wrong place with large offset
d)100BASE-T1 compliance test: displayed units of test result and judgment criteria are inconsistent
e) 100Base-TX and 1000Base-T: algorithm optimized
f) USB 2.0: compatible issue with USB IF recommended fixture
g) 1000BASE-T: transmission distortion test automatically executes without confirmation after completing one pair under the pairALL differential probe test
Compatible with hardware version with 32 GB internal storage
1.Optimize vector signal quality
2.HW Information displays the hardware serial number.
3.Remove “None” from the Custom filter type.
4.Added filter settings to ARB waveform settings.
5.Remove filter settings in ARB settings.
6.Added armed auto mode to ARB trigger.
7.The maximum number of multitone has been increased to 25001.
8.Supports playback of GSM, DAB, and WCDMA protocol waveforms.
9.Added automatic startup for SMB server and supports setting SMB server password.
10.Fixed several bugs
a)SCPI modulator attenuation type display instruction error.
b)Switching LF on the LF source page will not refresh the LF icon at the top.
c)TXT file playback error.
d)When playing txt and wdbin files, a local folder is generated in the root directory.
1. Support adjustment of cursor result display position.
2. Support displaying the average sampling count in the lower right corner of the screen.
3. Support knob acceleration function for cursor value and derivative step.
4. Support setting Math vertical offset and derivative step through the keypad.
5. Optimize trace colors after screen invert (C1 as yellow, C2 as green).
6. Fixed several bugs:
a) Issue where channel invert setting is not saved after reboot..
b) Issue with universal knob indicator light status error.
c) Issue when the menu is hidden, opening History or Search does not show the menu.
d) Issue when measure gate at the screen boundary, the device cannot be powered on after reboot.
e) Issue of missing prompt when adjusting parameters with knob in FFT split-screen mode.
f) Issue where reference label was displayed incorrectly when obscured by menu.
g) Issue of inaccurate AC measurement when inputting large offset AC signal.
Bug Fixes:
1. Fixed issue with Reverse Response Thru Calibration.
2. Fixed issue with log dialog.
3. Fixed issue with recalling state file by SCPI.
4. Fixed issue with abnormal power of SA function under specific conditions.
Solved Issues:
New Functionality:
Solved lssues:
Solved Issues:
1.Modified the return of * OPT and added custom IDN and OPT
2.Added LXI
3.Add SCPI command recording function
4.Fixed some bugs
a) Resolve the issue of not reducing the option numbers of uses
b) Resolve the issue of incorrect power in certain situations
1.Display: Supported 100ms, 200ms, 500ms persistence;Supported large font;Optimized the display of custom probe attenuation in the channel description box
2.Fixed several bugs:
a)In Normal trigger mode after one minute the waveform will be refreshed automatically
b)In edge trigger mode Alternating can only trigger on rising edge or falling edge
c)In roll mode level of pattern trigger cannot be set
1. Resolved the issue where SDG800 bandwidth upgrades did not take effect immediately and required a restart.
Fixed some bugs:
1. SCPI instruction configuration exception when inactive channel is set as trigger source.
2. Under the interpolation time base, CSV files need to save the original sampling points, not the interpolated points.
3. After recalling the settings file, sometimes the cursor settings are incorrect.
4. In tracking mode, using the SCPI command to change the source of an X cursor will cause the sources of X1 and X2 to change simultaneously.
5. After setting the reference level for FFT, power down and restart to restore the reference level error.
6. In the average sampling mode, when the time base is modified under a large time base, the waveform does not clear the old sampling points.
7. SCPI instruction reads FFT cursor, returns incorrect unit.
8. Sometimes UART decoding stop bit judgment error.
9. When the unit is mHz, the frequency value read by SCPI is in MHz units, which confuses uppercase and lowercase.
1. Supports webserver (0x6 version hardware); adds virtual panel in web control mode.
2. Screenshots support PNG file format.
3. Adds low-resolution output mode to DC output.
4. Sweep add step mode.
1. Add automatic power-on function.
2. Issues Fixed
1. Add the *RST command..
1. Add the *RST command..
Made Option 16LA Standard
1. Fixed several bugs
a) Cannot exit from Bode plot in some case
b) Cannot detect active probes correctly when the probes are connected at power-on
c) “Set to 50% level” takes the scope frozen in some case
d) Sample rate is displayed incorrectly after reboot from Fixed Memory Length mode
1. Modify the LIST configuration to match EasyPowerX.
Bug Fixes:
1. Fixed issue with Reverse Response Thru Calibration.
2. Fixed issue with log dialog.
3. Fixed issue with recalling state file by SCPI.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
Solved Issues:
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
Solved Issues:
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
Solved Issues:
1. Decode: Added Spacewire, USB2.0, CAN XL
2. Measure:
a) Added item: UpperLower
b) Added Source: ZFx, ZMx
c) Supported zoom in the measure histogram
3. Cursors: Supported to hide Y cursors in track mode
4. Math:
a) Supported up to 8 traces
b) Added operators: Envelope, tan, atan, FFT Phase
c) FFT:peak added delta display; marker added ordering by number, amplitude and frequency
d) FFT:Added windows Blackma_Harris and Gaussian
e) Supported to hide traces
5. Analysis:
a) SignalScan added decode search
b) Eye Diagram: added Vpp measurement
6. REF: Supported to hide traces
7. Zoom:
a) ZFx supported to set horizontal scale independly; ZFx, ZMx supported to synchronize the display region with Zx
b) Supported to set Zx’ vertical scale with unified adjustment
8. Roll:
a) Supported decode in Stop mode
b) Supported Roll + Zoom in fast display mode
9. Prode: Supported CP150, HVD3106A; Supported to set external scaling of SAP2500D
10. Save/Recall:
a) Autosave supported to save pictures
b) Supported to save all channels’ data to a single file
c) FileManager:Supported to view a picture in full screen mode
11. Display:
a) Axis label supported to set the vertical label on center and right
b) Supported to change the font size
12. System: Time/date supported NTP; Supported education mode
13. Webserver: supported inverted screenshot (according to the Image style setting in the Save menu) ; Added Run/Stop virtual button
14. SCPI: Added command MANual to support to set Amplitude Strategy of Measure
15. Fixed several bugs
a) Sending SCPI commands continuously lead the instrument to frozen state
1. Decode: Added SpaceWire, CANXL; added level hysteresis
2. Math:
a) Added operators: atan, Fiter
b) FFT: added windows Blackman-Harris and Gaussian
3. Measure:
a) Added item: Bit Rate, Data Rate, UpperLower, △TimeMax、△TimeMin
b) Supported to limit the display digits of measure
4. Roll: Supported Math and decode in Stop mode
5. Webserver: supported inverted screenshot (according to the Image style setting in the Save menu); added Run/Stop button
6. Save/recall: Supported Auto Save; support “Select All” operation in FileManager
7. UI:Supported to specify Zoom region by drag a rectangle; supported movable channel label
8. Utility:Supported password for screen saver
9. SCPI: added command for △time; added command to hide right menu
10. Fixed several bugs:
a) To hide Y cursors in track mode
b) In ERES + Roll mode, head of the trace is incorrect
c) When saving a .mat file it is possible to lost the last 4 bytes
d) Issues on matching SCP current probes
1. Improve the UI.
2. Fix the bug in the trend chart.
3. Modify the number of file systems from 2 to 3 and copy some
configuration files to new location .This will reduce the chance of
a system crash.
4. Need to use transition software to update from old to new
version.
1. Fixed some unit faults in 06version
2. Fixed some bugs about communication with easysdm.
1. Add the customer sensor support.
2. Add the manual calibration support.
3. Optimize flash R&W design。
4. Fix some UI & SCPI bugs
1. Add and optimize the manual calibration function
2. Solve the socket communication in multiple cycles of
open/close, may not respond to the problem
3. Fix the problem that the “READ” command does not
match the description in the programming manual
4. Fix the key test screen no prompt
5. Optimize the connectivity test buzzer response speed
issues
1.Long press the left button: one beep sounds,
and the prompt “CC mode prompt tone
disabled” plays.
Long press the left button again: two beeps
sound, and the prompt “CC mode prompt tone
enabled” plays.
1.This firmware is only compatible with
hardware version V6.1.
2.The MCU has been changed to GD32F427.
Firmware versions 1.01.01.02.XXX cannot be
upgraded.
1.Long press the left button: one beep sounds,
and the prompt “CC mode prompt tone
disabled” plays.
Long press the left button again: two beeps
sound, and the prompt “CC mode prompt tone
enabled” plays.
1. Fix: The UI was not updated in time when the power meter was pulled out.
2. Fix: GPIB Address can not be changed.
3. Fix: The mouse is hidden under VNC.
4. Fix: Some wrong SCPI commands were executed.
5. Optimize function with OCXO module.
6. Optimize power meter function.
1. Fix: In the custom mode, when save the state, some items are not saved.
2. Fix: Arb mode and pulse mode conflict. Now they can work simultaneously.
3. Fix: In Arb mode, there are some spurs, when On/Off the RF Mode button.
4. Fix: Some problems about LAN setting, VNC
1. Reduce the overshoot in the pulse function
2. Add pause function and the amplitude can be changed during pause status in
frequency step sweep mode.
3. Added some setting’s SCPI commands.
1. Added user manual calibration and verification function
(option).
2. Added the function that the number of vertical grid can be
set.
3. Added the function of supporting logarithmic display of
vertical coordinates.
4. Added point limit function
1. Added Pulse modulation function.
1. Fixed the range limits for frequency and power in mixer
measurements.
2. Fixed the trace title bar color to match the memory trace
color.
1.Add manual configuration of DC under TDR.
2.Add calibration overwrite function.
3.Optimize synchronization of external triggers for pulse
measurements.
1. Add material measurement function option.
2. Add switch matrix expansion multi-port application options.
1. Add gain compression measurement and vector mixing
measurement function.
Features and Enhancements:
1. Added Automatic Fixture Removal.
2. Added Noise Figure Measurement.
3. Added Power Meter Viewer Dialog.
4. Added support for cal kits with Sliding Load and Offset
Load.
5. Added support for HiSLIP communication protocol.
Bug Fixes:
1. Fixed a problem when changing IF bandwidth.
2. Fixed issue where changing directory in the File Browser
would cause GUI crash.
3. Fixed issue where multi-channel calibration would cause
crash.
4. Fixed issue where cal file would not correctly save or recall.
5. Fixed issue where sweep time would not estimate correctly
after adding a SA channel
6. Fixed issue with calibration type list display.
7. Fixed a bug where loading S2P file for 2-port de-embedding
would cause crash
8.Fixed issue with calibrating with a DATA-BASED
calibration kit.
9. Fixed issue with recalling CSV or SNP data files.
1. Add shortcut buttons at the toolbar.
2. Fix the stuttering problem when adjusting the brightness of
the grid in the waveform area.
3. Solve the problem of probabilistic crashes when opening
dialogs.
4. File storage shortcut keys support more types.
5. Support more power meters.
6. Add picture editing function to the screenshot dialog.
7. Adds peak reference function for bandwidth search.
8. Modify the contents of the Chinese and English help files
9. Modify the user receiver calibration process.
10. The input box will pop up automatically when using the
toolbar button to add Marker.
1.Solved the menu button is not updated when the electronic
calibration module is inserted or removed.
2. Fixed a bug that the touch screen may crash under some
cases.
3. Fixed an option installation bug.
1. Added spectrum analyzer option.
2. Fixed input bug in network configuration window.
3. Fixed mouse click input box crash bug.
4. Increased the touch-sensitive area of the DHCP checkbox.
5. Modified the policy when the DHCP request fails.
1. Added independent configuration function of emission
source in spectrum mode.
2. Optimized the sweep process.
3. Optimized TDR interface.
4. Added command for transferring file data.
5. Added marker->SA commands.
1. Added Frequency Offset function.
2. Optimized some functions of spectrum analysis.
3. Added status bar to display smooth status.
4. Added advanced mode for bandwidth search, support
frequency percentage bandwidth setting function.
5. Optimized the Marker->Delay algorithm.
Features and Enhancements:
1. Added Automatic Fixture Removal.
2. Added Noise Figure Measurement.
3. Added Power Meter Viewer Dialog.
4. Added support for cal kits with Sliding Load and Offset
Load.
5. Added support for HiSLIP communication protocol.
Bug Fixes:
1. Fixed a problem when changing IF bandwidth.
2. Fixed issue where changing directory in the File Browser
would cause GUI crash.
3. Fixed issue where multi-channel calibration would cause
crash.
4. Fixed issue where cal file would not correctly save or recall.
5. Fixed issue where sweep time would not estimate correctly
after adding a SA channel
6. Fixed issue with calibration type list display.
7. Fixed a bug where loading S2P file for 2-port de-embedding
would cause crash
8.Fixed issue with calibrating with a DATA-BASED
calibration kit.
9. Fixed issue with recalling CSV or SNP data files.
1. Fixed “button does not respond after self test”
1. Add “PNG“ file type for screenshot.
2. Support TG in RBW less than 30 kHz.
3. Modify default TG output power, -20 dBm in spectrum ananlyzer mode and 0 dBm in
reflection measure mode, and some other TG issues.
4. Updating the format of “LIM“ file. After this firmware , the old limit files will not be
supported. You can recreate them through “EasySpectrum” free software easily.
5. After this firmware, do not support downgrade operation.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Add socket/telnet-scpi, you can operate remote control through LAN port without
NI-VISA installed. Please see SSA3000X‘s Programming Guide for more details.
3. Change two limit lines in different colours.
4. When quit from TG, stay in“Auto” sweep.
5. Lower some spurs when FFT.
6. Improve the stability.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Improved the stability of sweep and avg detect.
3. Fixed some bugs on sweep, frequncy counter and Log-Log scale.
4. Fixed some bugs on SCPI and the AMK option.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Fixed v1.2.8.5 bugs on Refl Mode.
3. Fixed v1.2.8.5 bugs on language and file
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X
has an earlier version, please update to V1.2.8.1 first and then proceed to
update to the latest version.
2. Fixed bugs on peak search and next peak.
3. Optimize SCPI commands for peak table, screenshot, etc.
4. Optimize the LOG X-scale for EMI test.
5. Optimize the Quasi-Peak detector accuracy for EMI test
Notice:
This firmware must be upgraded from v2.1.1.1 or later. If your analyzer has an earlier version, don’t use this FW to update.
Improvements:
Optimize the Ref level and Att couple
Solved Issues:
Fix the zero sweep type when fft in SA mode
Fix the OPC response in EMI mode
Improvements:
• Optimize trace, marker, signal track, TG normalization,Reflection measurement in SA Mode
• Optimize web server UI
Solved Issues:
• Fixed video trigger fail, errors in Harmonic measurement in SA Mode
• Fixed spectrum amplitude error, meas error, waveform discontinue in MA Mode
• Fixed English help, system message
Improvements:
• Add Limit mask offset in SA mode
• TG Level adjustable in Reflection Meas
Solved Issues:
• Fixed AM and FM symbol rate error, Lpf coefficient error, in AMA mode
• Fixed Filter bandwidth error in DMA mode
• Fixed Freq counter error in SA mode
• Fixed Harmonic error in SA mode
• Help Display error
New Functionality:
• Update EMI option to a new EMI measurement mode
Improvements:
• Improve TG output harmonic performance
• Update Help file
Solved Issues:
• Fix ADC overload warning
• Fix Ch Power calculation bug in small span
Solved Issues:
• Fix avg power bug in EMI Mode
• Fix amplitude bug in AMA Mode
• Fix peak search bug in SCPI command
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
This version con not be rolled back
• Fix TG switch error at small RBW
• Fix Help and Limit file lost when Factory reset
• Fix CNR calc error when no peak found
• Fix OBW result overflow
• Fix Harmonic calc error at 100Hz RBW
• Fix Reflection Open+Short calibration action
• Fix spectrum amplitude error in DMA mode
• Optimize EMI .csv file content to all signal list
• Optimize EMI peak search
• Optimize Auto cal process
• Add Peak search to Spectrum in DMA mode
• Fix TG switch error at small RBW
• Fix Help and Limit file lost when Factory reset
• Fix Auto open delay unit error in VNA mode
• Fix CNR calc error when no peak found
• Fix OBW result overflow
• Fix Harmonic calc error at 100Hz RBW
• Fix Reflection Open+Short calibration action
• Fix spectrum amplitude error in DMA mode
• Optimize EMI .csv file content to all signal list
• Optimize EMI peak search
• Optimize Auto cal process
• Add Peak search to Spectrum in DMA
Fixed several bugs
a) A bug in file system could cause the
generator never startup
b) Can not wake up from screen saver from
time to time
Fixed several bugs
a) A bug in P12R1 which could cause the
update to fail
b) Some typo in English help system
It is strongly recommended to update to the latest
release because in some previous release exists
some serious bug which could cause the generator
never startup
1. Supported system recovery from the U-disk
2. Supported Rev.C hardware with Over Voltage
Protection
Fixed the incorrect sweep direction bug
Fixed the abnormal display issue during start-up on
some units with previous releases. It is not
necessary to update to this version if the unit has
no such a problem.
1. Supported to automatically enable the output
after power-on: Utility | Output Setup | Power
on State
2. Compatible with Rev.E hardware
1. Added statistic function in counter mode
2. Supported using method 2 from our “generating
mulitphase waveforms” application note (refer to
http://www.siglentamerica.com/prodcut-pxzl.aspx?id=9
0&tid=16&T=2) to synchronize 2 units of SDG2000X
3. Fixed some bugs
a) A bug in file system could cause the generator
never startup
b) DHCP does not run at power up
c) Channel lock phase can be wrong in modulation
sometimes
d) Error in calculation of frequency deviation in
counter mode
e) Instrument does not allow CH1 and CH2 to both
use the external input for the modulation source
simultaneously in tracking mode
f) Downward compatibility of .xml state file
g) Unable to delete files with uncommon character(s)
in their names
1. Allow 0 Hz for CH Frequency In MOD Modes PM, AM,
DSB-AM, ASK, PSK
2. Allow MOD frequency > CH Frequency In MOD Modes
PM, DSB AM, ASK
3. Allow DSB-AM, AM MOD Modes In TrueArb Mode
4. Up Followed by Down Sweep Mode is Supported in
Linear Sweep (No Change for Log Sweep)
5. Added ARB waveform name to display, allowing user to
know what Arb waveform is loaded
6. Fixed some bugs
a) Arb Waveforms In DDS Mode Have One (Small)
Glitch Per Cycle
b) Built in Ramp waveform has a flat spot issue at the
rising slope zero crossing right at the SYNC pulse.
c) Power Up Last Does Not Remember
SRate/Frequency Setting
d) MOD Type = DSB AM Has Amplitude Issues
1. Supported system recovery from U-disk.
2. Fixed a bug which may cause the generator report a
false over voltage alarm when start-up.
Optimized calibration and PV process on the production line.
1. Changed the amplitude strategy of AM modulation: The
carrier stays fixed at the amplitude, regardless of the
modulation setting.
2. Increased the upper limit of Harmonics number from 10
to 16.
3. Supported Multi-Device Synchronization.
4. Supported Up followed by Down Sweep mode in Linear
sweep (no change for Log sweep).
5. Added an icon to indicate clock source is internal or
external.
Internal: External:
External and the clock is lost:
6. Changed the clock switch strategy: When the clock
source is set to External and no actual external clock
signal is being received, the clock source will not switch
to Internal automatically but the clock icon will
indicate that external clock is lost
7. Supported specifying Arb type by remote control when
the modulating waveform is Arb.
8. Optimized the UI of selecting built-in arbs
9. Supported changing the unit of amplitude without any
amplitude change by long pressing the “Amplitude”
softkey.
10. Added “User” option under “PowerOn Setting”.
11. Added “Normal” as a new UI color style.
12. Added memory space information in Store/Recall UI.
13. Optimized response of the universal knob
14. Added indicator for double function of the soft keys
=>
15. Removed the warning message when parameter is set
to a value beyond the limit
16. Fixed several bugs
a) [2017/04/07-92573] Digit changes when setting
delay of Pulse by the knob
b) Amplitude unit “dBm” is not remembered after a
reboot
Optimized debounce of the front panel buttons.
1. Compatible with Rev.F hardware
2. Support trig dual channel separated when use mannul
trigger.
3. Support using another channel as the modulation
source
4. Support setting the output frequency after the
completion of sweep
5. Counter add fast measurement mode
6. Change the square waveform data used in square FM
modulation
The first formal release
1. Optimized TrueArb algorithm and added 3 types of
interpolation: sinc, sinc27 and sinc13
2. Optimized jitter performance of Square and Pulse
3. Optimized algorithm of Noise generating so the bandwidth
setting lower limit of Noise optimized from 80 MHz to 1
mHz
4. [2017/12/22-174663] Changed the clock switch strategy:
When the clock source is set to External and no actual
external clock signal is being received, the clock source
will not switch to Internal automatically but the clock icon
will indicate that external clock is lost
5. [2017/12/22-174663] Changed default state of 10 MHz
Out to “Disable”
6. Added Slave Delay option in Multi-Device Synchronization
function
7. Added indicator for double function of the soft keys
=>
8. Fixed the following bugs:
a) Crashes when downloading 20 Mpts waveform data
from the EasyWave program
b) Inaccurate burst delay
c) In TrueArb mode enabling AM with large amplitude
may trigger OVP
d) Switching the waveform from IQ to sine with large
amplitude may trigger OVP
e) Switching off the output on the SDG6kX only drops
the output level by approx 20 dB but does not
completely switch it off
1. Removed the warning message when parameter is set to
a value beyond the limit
2. Supported to copy/paste/delete folder in Store/Recall file
manager
3. Optimized initialization time when the waveform is
switched between IQ and other waveforms
4. Supported phase compensation in IQ mode
5. Fixed several bugs:
a) [2018/09/14-924144, 2018/09/14-937446] Signals
get interrupted upon timing-related change of the
settings in Independent mode
b) Anomaly on square/pulse waveform with some
setting
c) [2018/11/06-92208] Anomaly on arb waveform when
toggle the “ArbMode” from DDS to TrueArb and
back to DDS in Independent mode
1. Changed the upper limit of carrier frequency (sine) in
Burst mode from 300 MHz to 500 MHz
2. Added some missing SCPI commands
3. Fixed several bugs:
a) Messed up signal after switching from 500 MHz sine
to square in independent mode
b) Glitches when outputting pulses under certain
circumstances in independent mode
1. Allowed one channel to modulate the other
2. Supported Burst in TrueArb mode
3. Supported Burst Counter in Burst mode so the number of
burst trains can be set to > 1 when trigger source =
external or manual
4. Added an option to let the SDG start with activated
outputs
5. Added 50 ohm output impedance text in the UI
6. Able to remember the digit of a parameter that had been
modified
7. Fixed several bugs:
a) DDS interpolation bug
b) Switching on/off output causes random phase
deviation between channels in Track mode
c) Incorrect square/pulse waveform initialization in
some cases
d) Unable to store the level settings for noise
e) Unable to recognize the command MODE
PHASE-LOCKED
f) Freezing issue when being written a 20MB long file
with the EasyWaveX
g) The setting “BANDSET” with Waveform = NOISE
leads to inconsistent behavior on the Noise
Bandwidth of the output signal; The real-time noise
bandwidth on channel 2 is changed if an AM sine
modulation is switched on channel 1
h) Unable to install the IQ option before 30 trials run out
1. Fixed several bugs:
a) Add edge trigger for any edge trigger type
b) Bandwidth Limitation in Roll Mode
1. Fixed several bugs:
a) Add edge trigger for any edge trigger type
b) Bandwidth Limitation in Roll Mode
Resolved the issue where channels could not be triggered independently when both channels were in manual trigger mode.
Fixed some issue on the production line. From user’s perspective no difference with 1.2.3.1
1. Measure: added new items UpLower, △TimeMax, △TimeMin
2. Math:FFT – added windows Blackman-Harris and Gaussian
3. Decode: Added SpaceWire, CANXL
4. Roll: Supported Math in Stop mode
5. Channel: in Eres mode to display the corresponding bandwidth
information in the descriptor box
6. Digital
a) Digital channels ASCII decoding requested
b) Optimized labels’ display
7. Save/Recall:
a) Supported AutoSave
b) File Manager: Supported to Select All
8. WebServer: supported inverted screenshot (according to the Image
style setting in the Save menu); added virtual front panel; added
Run/Stop button
9. UI:
a) Supported custom colors for XY trace
b) Supported to disable Time/Date display
c) Supported to specify Zoom region by drag a rectangle
10. Utility:
a) Supported password for screen saver
b) Key test: Supported to test the rotation direction of the encoders
11. Remote control:
a) a) added commands for counter
b) added commands for △time measurement
12. Fixed several bugs:
a) When saving inverted screenshot as JPG, PNG, trace color of
channels changes
b) SCPI commands don’t work in some cases setting horizontal
parameters
c) Phase measure doesn’t work in some case
d) In Eres mode, abnormal display on trace with 10Mpts length
13. Some SCPI issue on digital channels
1. Decode: Added SPMI, Spacewire, USB2.0, CANXL
2. Math:
a) Added operators: tan, atan, envelope, delay, FFT phase
b) FFT: added windows Blackman-Harris and Gaussian
c) Formular editor: supported measure item as the component of a formula
d) Supported Trend and Track as math trace
3. Measure:
a) Added item: Bit Rate, UpperLower
b) Supported to limit the display digits of measure
c) Supported to display up to 24 items at the same time
4. Analysis:
a) Added Double Pulse Test
b) Added Serial Test
5. Probe: Supported SDP6150A, SDP6150D
6. Roll: Supported Math and track cursors in Stop mode
7. Display: Supported custom colors for XY trace
8. Webserver: supported inverted screenshot (according to the Image
style setting in the Save menu); added virtual front panel
9. Save/recall: Supported full screen mode when preview an image;
supported to save multi channels data as a single file; supported Auto
Save;
10. Utility:Added English help; Supported password for screen saver
11. Fixed several bugs:
a) The instrument becomes slower after long time run
b) Webserver: some control issue in full-screen mode
c) Cannot save a Memory trace to file
d) OPC command response error
1. Support SMB and NTP functions
2. Optimize the reading time for continuously switching gears at slow speeds
3. Repair the malfunction
a) BUG for incorrect readings when set to fast
b) The problem of manually setting the number of grids under the histogram failing
c) The issue of not saving time settings after restarting
d) The issue of failed first screenshot after inserting the USB flash drive
e) Cap automatic range failure issue under specific input
f) The problem of incorrect voltage readings when setting the input impedance to 10 Gohm is that selecting uA does not take effect in current mode
h) Abnormal reading function when dual display is turned on
Features and Enhancements:
1. Added Automatic Fixture Removal.
2. Added Millimeter Wave Measurement.
3. Added Noise Figure Measurement.
4. Added Power Meter Viewer Dialog.
5. Added support for cal kits with Sliding Load and Offset Load.
6. Added support for HiSLIP communication protocol.
Bug Fixes:
1. Fixed a problem when changing IF bandwidth.
2. Fixed issue where changing directory in the File Browser would cause GUI crash.
3. Fixed issue where multi-channel calibration would cause crash.
4. Fixed issue where cal file would not correctly save or recall.
5. Fixed issue where sweep time would not estimate correctly after adding a SA channel
6. Fixed issue with calibration type list display.
7. Fixed a bug where loading S2P file for 2-port de-embedding
would cause crash
8.Fixed issue with calibrating with a DATA-BASED calibration
kit.
9. Fixed issue with recalling CSV or SNP data files.
1. Add U disk recovery function.
2. Modify Hold function arithmetic.
3. Add the telnet SCPI function; port is 5024
4. Example: telnet 192.168.0.10 5024
1. Supports SMB and NTP functions.
2. Optimized noise after AZ is enabled.
3. Optimized noise after 100PLC is enabled.
4. Supports saving readings, statistics, and histograms in the scanner card function.
5. Supports relative value settings, statistics, and histograms in the dual display function.
6. Bug fixes
a) System crashes when entering the wrong password during recalibration.
b) Statistics occasionally show 0 in math.
c) Fixed an issue where overload values were recorded during probe-hold.
d) The digitizer would freeze at certain sampling rates and readings.
e) Device malfunctions occurred when using the scanner card’s universal remote control command function.
f) File path errors when browsing when holding readings.
g) Selecting uA in current mode did not work.
1. Linear frequency modulation increases waveform
display
2. Multi-tone supports independent control of
amplitude, phase and switch of each spectrum line
3. Compatible with SMBV100B remote commands
4. When the number of points in the marker file does
not match the number of points in the waveform file,
reset the marker to its initial value
5. Fixed several bugs
a) Solve the problem of failure to load custom
constellation map
b) Solve the problem of abnormal linear frequency
modulation waveform
c) Solve the problem that the power meter flatness
list filling is not effective
3st release
1. Support IQ waveform generated by customIQ of
SigIQPro;
2. Screenshot files support PNG and BMP formats;
3. MOD, SWEEP, BURST add RUN/Stop control function;
4. Support display of current output frequency during
frequency sweep;
5. Fixed the bug that the waveform is discontinuous when
the length of the sequence wave is not an integer multiple
of 16;
6. Enhance the sequence function, and the number of loops
of segment no longer occupies storage space multiple
times;
7. Delete the true arb mode of arb wave, and only keep the
DDS mode. The true arb mode is implemented by the
sequence (sequence with only one segment);
8. Solve the problem of abnormal output when the frequency
between 250MHZ and 300MHz during sweep;
9. Modify the default output polynomial of PRBS and support
programmable polynomial;
10. Sync output supports 50% duty cycle output mode;
11. IQ waveform information diaplay add data source
information;
12. Solve the problem of duty cycle is changed during
frequency change when square or pulse output;
13. Added a new DC output mode to solve the problem that
when changing the voltage, the output will jump to 0
before outputting. This method will reduce the output
accuracy;
14. Support amplitude sweep function.
1. Enhance the sequence function, and the number of
loops of segment no longer occupies storage space
multiple times;
2. Delete the true arb mode of arb wave, and only keep
the DDS mode. The true arb mode is implemented by
the sequence (sequence with only one segment);
3. Sweep adds step sweep mode;
4. Sync output supports 50% duty cycle output mode;
5. Optimize the operation response of the encoder;
6. Screenshot files support PNG and BMP formats; And
screenshot files are saved to the USB disk by default;
7. Added a new DC output mode to solve the problem
that when changing the voltage, the output will jump to
0V before outputting. This method will reduce the output
accuracy;
8. Modify the default output polynomial of PRBS and
support programmable polynomial;
9. Solve the problem of duty cycle is changed during
frequency change when square or pulse output.
Fixed a bug which may cause the touch screen no response
New ATT and RefLevel linkage solution.
Limit function optimization.
Other function optimizations and bug fixes
1. Support decode after roll stop
2. Support decode hysteresis
3. Support Blackman-Harris and Gaussian window of FFT
4. Support XY split screen display
5. Support movable channel label
6. Support saving measurement statistics results
7. Remote reading acceleration(SERVICE->WAV ACC)
8. Support exFAT format for USB disk
9. Optimize UI
a) Add confirmation dialog for save To Default Key
b) Remove excess zeros in the axis labels
c) When the horizontal axis labels are too long, they will
be displayed alternately up and down
d) Use real “µ” instead of small letter “u”
e) Optimize Keyboard Test
10. Fixed several bugs
a) When Beep enabled, physical buttons beep only until
first move of any encoder
b) When the probe is not 1X and the vertical reference
is Offset, the zoom area is unreasonable when
changing the vertical scale
c) When the points is ≥10M, FFT has unreasonable
spurious signals
Fixed an issue on production line. No difference with 0.9.9R7 from the user’s view
1. Fixed some issues on the production line
2. Fixed several bugs
a) Slow response in Jitter application
b) Restart fails with small probability
a. Solved the issue of overshoot when configuring certain LF functions
b. Solved the issue of no change in minimum scanning time after ALC switching
c. Add: BOARd: INFO? Command to obtain hardware information
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
⚫ Add measurement related functions, including:APSK function, Marker Band function, MA Record function and 200 Hz EMI RBW (only SVA1075X).
⚫ Add system related functions, including: local oscillator feedthrough self calibration, 10M out frequency accuracy Self-Calibration function and FTP function.
Improvements:
⚫ Optimize the auto-save function, add the auto-save switch and auto-save time function to Last Preset.
⚫ Add SCPI command, you can use the pscpi command to set/query the reference clock source used by the machine.
⚫ Improve the measurement function, including increasing the number of markers in VNA mode to 14; optimize the measurement accuracy of the channel power measurement mode to ensure higher measurement accuracy.
Solved Issues:
⚫ Fixed some known defects.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
⚫ Add measurement related functions, including:APSK function, Marker Band function, MA
Record function and 200 Hz EMI RBW.
⚫ Add system related functions, including: local oscillator feedthrough self calibration, 10M out
frequency accuracy Self-Calibration function and FTP function.
Improvements:
⚫ Optimize the auto-save function, add the auto-save switch and auto-save time function to
Last Preset.
⚫ Add SCPI command, you can use the pscpi command to set/query the reference clock
source used by the machine.
⚫ Improve the measurement function, including increasing the number of markers in VNA
mode to 14; optimize the measurement accuracy of the channel power measurement mode
to ensure higher measurement accuracy.
Solved Issues:
⚫ Fixed some known defects.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
⚫ Add measurement related functions, including:APSK function, Marker Band function, MA Record function and 200 Hz EMI RBW(only SSA3075XPlus).
⚫ Add system related functions, including: local oscillator feedthrough self calibration, 10M out frequency accuracy Self-Calibration function and FTP function.
Improvements:
⚫ Fixed some known defects.
1. Fixed some issues on the production line
1. Add a pop-up window when switching frequency
causes IQ mode to be turned off
2. New options: “SigIQPro-IEEE.802.11.a/b/g/n/ac”
3. Added linear frequency modulation function
4. Fixed several bugs
a) Solve the problem of inaccurate power when
turning on RF in IQ mode
b) Solve the problem of inaccurate power after
turning on arb filtering
c) Solve the problem of insertion failure after
clearing the multi-carrier list
d) Solve the problem of abnormal waveform after
peak clipping/scaling
1. Solve the problem that the sync signal is
output when the channel is not turned on
2. After the sweep is completed, the output
frequency is modified to stay at the initial
frequency of the sweep
New Functionality:
Add user calibration for reference clock Improvements:
SA mode: optimize refresh efficiency
AMA mode: optimize AF smoothing effect
NF mode: exporting table results as .csv files
Add FTP switch function Solved Issues:
SA mode: align estimated scan time and regular scan time
BT mode: solve issues including Preset, EDR signal demodulation, and no response to quick operations
PN mode: solve issues including signal averaging failure and incorrect sweep width
NF mode: solve issues including calculation errors
RTSA mode: solve issues including no waveform in screenshots, peak failure,failure to save and load files, and missing reference offset
Add and modify SCPI commands:
1. Period cursor reading error (:CALCulate:MARKer:FCOunt:X?)
2. Query cursor function returns off (CALCulate:MARKer:FUNCtion?)
3. Setting external trigger command is inconsistent with programming manual(:TRIGger[:SEQuence]:SOURce)
4. Harmonic analysis command is missing to obtain each order harmonic frequency and power and obtain total harmonic distortion(:READ:HARMonics:AMPLitude:ALL? :READ:HARMonics:DISTortion?)
5. SA command reads back cent, low, high.Q results when obtaining NDB results(:CALCulate:MARKer:BANDwidth:RESult?)
1. Remove the knob acceleration function; Pressing the FINE key allows you to adjust the numerical value by selecting the digit, decile, and percentile, and the selected number will be highlighted.
1. Supported new AP models: SDS7804AP, SDS7604AP
2. Supported Enhanced Bandwidth on 4GHz and below models (Only applied to units which are produced with 1.1.9.1R1 and later FW)
3. Improved the response speed in the case of deep waveform length
4. Compliance test:
a) Added MIPI-DPHY
b) Added 2.5G/5G/10GBASE-T
c) For USB2.0, added Receiver Sensitivity test, and supported
upgrading the FW of the fixture by the scope
5.Math:
a) Added operators Tan, Atan
b) Added operator FFTPhase
c) Added new windows Black-Harris and Gaussian for FFT
6. Decode: added CANXL
7. Optimized refresh speed in the case of Roll + Zoom
8. Eye Diagram: added Second order PLL for Clock Recovery
9.Save/Recall:
a) Supported to save all segments in sequence mode to one
single .mat file
b) Supported to save all channels’ data to one file
c) Supported Full Screen view of pictures in File Manager
10. Supported Wake-on-LAN (Some setting change is necessary. Contact
SIGLENT for detailed information)
11. WGEN: supported the case in which built-in and external generators
are both in use
12. Fixed several bugs
1. Fixed several bugs
a) Scope wont’t boot if set for DHCP and connected to LAN
without DHCP server
b) An “Acquiring” progress bar is showing up on 1 ms/div
instead of 100ms/div as before
c) Remove BW Limit warning
d) When FFT is set to certain frequency bands, such as 1kHz
to 6kHz, meaningless axis labels are displayed (sweep
mode is set to logarithmic)
1st release
1. Optimize reference code and add variable reference process
2. Set the target power setting range in power control to the indicator range of power
meter, and add the models of power meters of Keysight and RD
3. Solve some bugs
1、Modify the display of log information according to the configuration of CFG file
2、Optimize reference code
3、Add judgment of upper computer options
1. Supported multi-pulse waveform output.
2. Supported sequence playback.
3. Added new “step” sweep mode, and changed the
minimum sweep time to 5us.
4. Added the function of long pressing knob to save
screenshots.
5. Optimized knob response to solve the problem of
occasional code loss.
6. Added SCPI command for synchronous output of two
channels.
7. Added burst hold setting function for burst output.
8. Supported license installation by U-disk.
9. Supported MAC address display.
10. Solved the problem of output error under FSK modulation
when frequency above 300 MHz.
11. Solved the problem of occasional non-response for SCPI
command when connected by socket.
12. Solved the problem of system crash when importing large
CSV waveform file by U-disk.
1. Support decode after roll stop
2. Support decode hysteresis
3. Support Blackman-Harris and Gaussian window of FFT
4. Support XY split screen display
5. Support movable channel label
6. Support saving measurement statistics results
7. Remote reading acceleration(SERVICE->WAV ACC)
8. Optimize UI
a) Add confirmation dialog for save To Default Key
b) Remove excess zeros in the axis labels
c) When the horizontal axis labels are too long, they will be
displayed alternately up and down
d) Use real “µ” instead of small letter “u”.
9. Fixed several bugs
e) When Beep enabled, physical buttons beep only until first
move of any encoder
f) When the probe is not 1X and the vertical reference is
Offset, the zoom area is unreasonable when changing the
vertical scale
g) After NTP synchronization time, the history list time is
wrong
h) When the points is ≥10M, FFT has unreasonable spurious
signals
1.The strategy for controlling the fan is optimized.
1、Fix bugs related to DHCP and preset functions.
1. Supported new low impedance passive probe SP6150A
2. Optimized SCPI command“WF”
3. FileConverter tool upgraded to version 3.5.8
4. Fixed several bugs
a) SCP5500 bandwidth displayed incorrectly
b) Scope + SCP5030A probe configuration is slow in Roll mode
c) PSRR measurement unexpectedly returns to bode plot
d) Some error in saving .mat files
New Functionality:
• Added EMI mode.
• Added SCPI commands to query files in a specified directory.
Improvements:
• Optimized the system information interface.
• Supports saving measurement results in txt format under AMA and DMA Mode.
• Optimized the calculation accuracy of Band Marker.
Solved Issues:
• Fix DHCP failure after IP conflict.
• Fix IQ collection.
• Fix map compression package reading error,and the playback points displaying error.
1. Add gain compression measurement and vector mixing measurement functions
1. Add Gain Compression Measurement and Vector Mixing Measurement function
1. Add manual calibration frequency accuracy function
1. Supported new model: SDS7604A H12
2. Cursor: new cursor strategy, supporting multi cursors
3. Made Option 16LA Standard
4. Fixed several bugs
a) Stuck at splash screen after upgrade
5. Power off operation at start-up process brings the instrument to dead
1. Optimized the UI
2. Analysis: Added SignalScan, a powerful tool which can automatically
scan the acquired signals on the software according to the scan
conditions set by users, and mark them with red vertical lines or
rectangular boxes
3. Zoom
a) Supported ZFx (Zoom of Math trace) and ZMx (Zoom of Memory
trace)
b) Supported M1 and M2 modes (Acquire | Zoom). In M1 mode all
Zx channels share the same vertical scale while in M2 mode the
vertical scales are separately adjustable
4. Serial Decode:
a) Supported Math and Memory trace as source
b) Supported decode in Roll mode (Stop status)
c) Added Hysteresis
d) Added One Key Search (Recalling SignalScan to search the
specified item) for SPI, I2C and UART
5. Mask Test: Supported Math and Memory trace as source
6. Measure: added item UpperLower、△time1~4
7. Math
a) Supported Measure result (MeaX) as part of the formular
b) Added new operator: Envelope
c) FFT:Added new windows: Blackman_Harris and Gaussian
8. Channel: Supported movable label
9. WebServer: Added virtual front panel
10. Save/Recall: Added new item Project (including setup, waveforms and
screenshots)
11. SCPI:Optimized transport efficiency of command WAVE
12. Fixed several bugs
1. Simplify the multi-pulse setup operation, and change
the operation mode to manual trigger by default
1、Solve bugs related to external modulation
1.Support LXI,PWM speed fan.
1. The flag font in CC state is changed to red.
2.In case of channel output,Press the aLL key to disable All ON/OFF output, and then press the All ON/OFF key to enable four out put channels.
1. The first release of the software version.
Optimized Self-cal time from 52 minutes to 22 minutes
Add open source declaration
1、The first released
2、Added open source agreement description.
1. Solve the problem of output desynchronization when
modulation depth/phase deviation/frequency deviation
is changed in channel tracking mode with AM/PM/FM
modulation
2. Solve the problem of abnormal output waveform when
switching back to the internal clock when the external
reference clock is abnormal.
3. Solve the problem of occasional abnormal output
waveform after power on
4. Add the function of long pressing store/recall to save
screenshots
1、Added open source agreement description.
1. Add an open source declaration
2. Optimize the display of options
Made Option 16LA and Option FG Standard
Made Option 16LA and Option FG Standard
Made Option 16LA Standard
Made Option 16LA and Option FG Standard
1. Made Option 16LA Standard
2. Added new Analysis function: Serial Signal Test (Analysis | Serial
Signal Test)
3. Optimized UI
4. Supported USB-GPIB adapter
5. Fixed several bugs
a) IP setting issue
b) Scope dead when FW upgrade fails in the case that space at
/local not enough
c) “Bended” / “tilted” trace at small V/div
d) Math: Filter sample rate adaption cannot work
e) Frequency / Period measurements fail on certain waveforms
1. Optimize Autosetup speed
2. Optimize SDS1104X-E bandwidth
3. Standard software functions of FG, LA and WIFI
1. Optimize UI, change “on/off” to “On/Off”.
2. Solve the problem that some numbers from 200-223 cannot
be entered in the first byte of the IP address.
3. Standard software functions of FG and LA.
1.The first time introduced.
2.Added open source agreement description
1. Optimize Autosetup speed
2. Optimize SDS1104X-E bandwidth
3. Standard software functions of FG, LA and WIFI
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• VNA mode Ecal add Ecal Check, S11 Ecal, S21 Ecal. Add SCPI Command for Ecal Check
[:SENSe#]:CORRection:ECAL:CONFidence:CHECk. Add SCPI Command for PV test
[:SENSe#]:CORRection:ECAL:S11:PVTest, [:SENSe#]:CORRection:ECAL:S21:PVTest
Improvements:
• Display the exit command in Remote Control mode interface.
• SA/EMI/MA mode saves the current trace when saving user configuration
• SA mode auto tune does not change the amplitude Unit and Scale Type (Log/Linear)
• EMI mode exports Freq Interpoaltion (Log/Linear) when saving lmt file, and import the configuration when recalling the lmt file.
Solved Issues:
• Fix the problem of MA mode setting the SCPI command for filter type:
DDEMod:FILTer:MEASurement setting root raised cosine and raised cosine failed.
• Fix the problem that when the EMI mode does not have touch screen function, it is impossible to pull down to see more measurement results
• Fix the problem of unit error when the command DISPlay:WINDow:TRACe:Y:SCALe:RLEVel for setting the reference level in the RTSA mode does not contain units
• Fix the problem that when the RTSA mode’s Persistence state is infinite, using the command DISPlay:VIEW:DENSity:PERSistence can still set the Persistence time
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
Improvements:
• Display the exit command in Remote Control mode interface.
• SA/EMI/MA mode saves the current trace when saving user configuration
• SA mode auto tune does not change the amplitude Unit and Scale Type (Log/Linear)
• EMI mode exports Freq Interpoaltion (Log/Linear) when saving lmt file, and import the configuration when recalling the lmt file.
Solved Issues:
• Resolve the error issue of the SA mode TG waveform at 1.158GHz-1.168GHz.
• Fix the problem of MA mode setting the SCPI command for filter type:DDEMod:FILTer:MEASurement setting root raised cosine and raised cosine failed.
• Fix the problem that when the EMI mode does not have touch screen function, it is impossible to pull down to see more measurement results
1. Add material measurement function option.
2. Add switch matrix expansion multi-port application options.
Solved some issue on production line
1. Sloved the device can not response command by NI VISA when the computer had installed Keysight VISA.
1. Added software options for accessory SCD30A.
2. Only upgrading to 1.02.01.27R2 can upgrade to this version
1. Supports EMMC flash.
2. Add user-defined cold end compensation for temperature measurement.
3. After upgrading to version 1.02, you cannot return to version1.01
1. Solve the problem of trigger holdoff fails.
2. Solve the problem of CAN decoding causing crashes with a
small probability.
3. Modify the kernel solve the problem that scpi cannot be used on a computer with keysight driver installed.
4. Solve the problem of advanced trigger (Qualified, Nth Edge,
Delay, Setup/Hold) parameters are not recalled.
5. Solve the problem of delay trigger level setting error.
6. Solve the problem of when the edge is set to Alternating,
trigger jitter will occur when entering the other trigger type.
7. Solve some known problems.
8. Optimize waveform capture rate.
9. Optimize Self calibration speed.
10. Optimize UI.
CAUTION: This release cannot be downgraded to previous releases.
New Functionality:
Add Phase Noise Measurement Mode
Add Noise Figure Measurement Mode
Add Pulse Measurement Mode
Add Blue Tooth Analysis Mode
Add AF spectrogram, SNR,Dist/Total,THD parameter analysis results in AMA
Mode
Add image browsing in SYSTEM
Solved Issues:
EMI mode Scan Only rescan with one less count issue
EMI mode sending command unable to rescan meter and Meas issues
1st release
1. Supported new probes: Siglent’s SCP5030, SCP5030A, SCP5150,
SCP5500 and LeCroy’s CP150, HVD3106A
2. Option to hide Memory and Math traces
3. Webserver: Screenshot can be directly copied and pasted
4. Fixed several bugs
a) Decode Threshold bug
b) NO persistence available with frames captured by SEQUENCE