High Resolution Oscilloscope

SDS5000X HD Series

SDS5000X HD

Bandwidth

1 GHz

Real time sampling rate

5 GSa/s

Channels

8 + EXT

SDS5000X HD

SDS5000X HD

Created with Pixso.

Product Introduction

SDS5000X HD supports 8 channels with 12-bit resolution, ultra-low noise, and precision measurements for multi-channel applications. An impressive array of measurement and math capabilities, as well as serial decoding are also features of them. The SDS5000X HD employs a 12.1’capacitive touch screen and supports multi-touch gestures, with the addition of user-friendly UI design, can greatly improve the operational efficiency.

Key Features

Bandwidth:1GHz,500MHz,350MHz
Memory depth: Up to 2.5 Gpts/ch waveform length
ADC:12-bit
Real time sampling rate: Up to 5 GSa/s
Waveform Capture rate:Up to 160,000 wfm/s

Product advantage

High resolution to meet the requirements of higher precision testing

12-bit high-resolution ADC sampling, better presenting waveform details.

Excellent noise floor, with noise floor as low as 140μV at 1GHz full bandwidth.

0.5% DC gain accuracy

Multi-channel timing test, power rail measurement completed in one go

Modern electronic systems incorporate various chips and modules whose initialization and operation may interfere with each other. Power-up sequence testing ensures that signals from different circuit modules follow the correct timing to avoid conflicts and guarantee system stability. For example, improper power-up sequences in communication systems can lead to data transmission errors. As circuit complexity increases, so do the challenges of power-up testing. The SDS5000X HD captures the entire power-up process of all relevant signals in a single acquisition, reducing measurement time, improving efficiency, and minimizing errors caused by repeated tests. For complex circuits with 8 power rails, this capability enables one-shot measurements.

Three-Phase Power Analysis

Using an 8-channel oscilloscope for three-phase power analysis allows simultaneous connection to all phases. It synchronously measures three-phase voltage and current signals, accurately capturing waveforms and parameters in real time. Users can directly observe and compare phase relationships to ensure balance. With the Fast Fourier Transform (FFT) function, multi-channel oscilloscopes perform harmonic analysis on three-phase signals. Optional three-phase analysis software supports vector diagram testing for motors, power quality assessment, ripple analysis, and efficiency evaluation.

Complete Wide Bandgap Semiconductor Testing Solution

The launch of Siglent latest 8-channel oscilloscopes and optically isolated probes completes the final piece of the wide bandgap semiconductor testing puzzle. The SDS5000X HD achieves a rise time at the picosecond (ps) level, capturing fast-switching waveforms of silicon carbide (SiC) and gallium nitride (GaN) devices. It analyzes transient voltage and current changes during switching, as well as characteristics like overshoot and ringing, to optimize circuit design and signal integrity.

Product parameter

Configure your instrument

Add to Compare ModelsBandwidthChannelsVertical ResolutionSampling RateMemory DepthCapture Rate Price  

Resources

Probe (Standard)
Created with Pixso. Created with Pixso.

Product
Description
SP5150A
SP5150A

Passive probe, 500 MHz bandwidth, 10X attenuation ratio, input impedance of 12pF || 10MΩ, with automatic identification function.

Click to view the probe manual

Other
Created with Pixso. Created with Pixso.

Probe
Created with Pixso. Created with Pixso.

Product
Description
SP6150A
SP6150A
Passive probe, 1.5 GHz bandwidth, 10X attenuation ratio, input impedance of 1.8pF || 500Ω, with automatic identification function.
SAP2500D
SAP2500D
Active differential probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, differential input impedance of 1pF || 200kΩ, offset range of 8V, SAPBus interface.
SAP2500
SAP2500

Active single-ended probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, input impedance of 1.1pF || 1MΩ, offset range of ±12V, SAPBus interface.

Click to view the probe manual

SAP1000
SAP1000

Active single-ended probe, 1 GHz bandwidth, 10X attenuation ratio, input impedance of 1.2pF || 1MΩ, offset range of ±12V, SAPBus interface.

Click to view the probe manual

HPB4010
HPB4010

High voltage probe, DC-40 MHz bandwidth, 1000X attenuation ratio, input impedance 3pF || 100MΩ.

Click to view the probe manual

DPB1300
DPB1300

High voltage differential probe, 50 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1300V, differential input impedance 2pF || 10MΩ, BNC interface.

Click to view the probe manual

DPB4080
DPB4080

High voltage differential probe, 50 MHz bandwidth, 10X/100X attenuation ratio, maximum differential voltage 800 V, differential input impedance 1.2pF || 54MΩ, BNC interface.

Click to view the probe manual

DPB5150
DPB5150

High voltage differential probe, bandwidth of 70 MHz, attenuation ratio of 50X/500X, maximum differential voltage of ±1500V, differential input impedance of 2pF || 10MΩ, BNC interface.

Click to view the probe manual

DPB5150A
DPB5150A

High voltage differential probe, 100 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1500V, differential input impedance 2pF || 10MΩ, BNC interface.

Click to view the probe manual

DPB5700
DPB5700

High voltage differential probe, 70 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.

Click to view the probe manual.

DPB5700A
DPB5700A

High voltage differential probe, 100 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.

Click to view the probe manual

SCP5030
SCP5030

Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, SAPBus interface.

Click to view the probe manual

SCP5030A
SCP5030A

Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, SAPBus interface.

Click to view the probe manual.

SCP5150
SCP5150

Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.

Click to view the probe manual

SCP5500
SCP5500

Current probe, DC-2 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, SAPBus interface.

Click to view the probe manual

CPL5100
CPL5100
Current probe, DC-600 kHz bandwidth, attenuation ratio of 10X/100X, current range of 50mA ~ 100Apk, powered by 12V adapter.
CP4020
CP4020

Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.

Click to view the probe manual

CP4050
CP4050

Current probe, DC-1 MHz bandwidth, 2X/20X attenuation ratio, maximum input 50Arms/140Ap-p, 9V adapter power supply.

Click to view the probe manual

CP4070
CP4070

Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.

Click to view the probe manual.

CP4070A
CP4070A

Current probe, DC-300 kHz bandwidth, attenuation ratio of 10X/100X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply.
Click to view the probe manual

CP6030
CP6030

Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.

Click to view the probe manual.

CP6030A
CP6030A

Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.

Click to view the probe manual.

CP6150
CP6150

Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.

Click to view the probe manual.

CP6500
CP6500

Current probe, DC-5 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, powered by 12V adapter.

Click to view the probe manual.

SAP4000P
SAP4000P
Power rail probe, DC-4 GHz bandwidth, 1.1X attenuation ratio, input dynamic range ±600mV, offset range ±24V, SAPBus interface.
ODP6050B
ODP6050B

Optical isolation voltage probe, 500 MHz bandwidth, common mode rejection ratio of 160dB, measuring voltage of 2.5 V ~ 2,500 V, isolation voltage of ±60kV.

Click to view the probe manual.

ODP6100B
ODP6100B

Optical isolation voltage probe, 1 GHz bandwidth, common mode rejection ratio of 160dB, measuring voltage of 2.5 V ~ 2,500 V, isolation voltage of ±60kV.

Click to view the probe manual.

SPL2016
SPL2016

16-channel logic probe (hardware), sampling rate and storage depth are determined by oscilloscope, which is suitable for dingyang technology SDS7000A, SDS6000 Pro, SDS6000L, SDS5000X HD, SDS5000X, SDS3000X HD, SDS2000X HD and SDS2000X Plus models.

Click to view the probe manual

Other
Created with Pixso. Created with Pixso.

Trigger/decode Options
Created with Pixso. Created with Pixso.

Product
Description
SDS5000HD-I2S
SDS5000HD-I2S

I2S Trigger/Decode Option (Software)

SDS5000HD-1553B
SDS5000HD-1553B

MIL-STD-1553B Trigger/Decode Option (Software)

SDS5000HD-FlexRay
SDS5000HD-FlexRay

FlexRay trigger & decode (software)

SDS5000HD-CANFD
SDS5000HD-CANFD

CAN FD trigger & decode (software)

SDS5000HD-SENT
SDS5000HD-SENT

SENT trigger & decode (software)

SDS5000HD-Manch
SDS5000HD-Manch

Manchester decode (software)

SDS5000HD-ARINC
SDS5000HD-ARINC

ARINC429 Trigger/Decode Option (Software)

Analysis Options
Created with Pixso. Created with Pixso.

Bandwidth/Channel Upgrade Options
Created with Pixso. Created with Pixso.

Hide Created with Pixso.