Handheld Signal Analyzer

SHA860A Series

SHA860A

Frequency Range

9 kHz-26.5 GHz

Maximum real time bandwidth

110 MHz

Vector Network Analyzer

100 kHz -26.5 GHz

SHA860A

SHA860A

Created with Pixso.

Product Introduction

Siglent SHA860A series, a next-generation handheld signal analyzer, integrates spectrum analysis, vector network analysis, and cable/antenna testing into a single portable platform, offering a comprehensive solution for 5G/LTE base station deployment and maintenance. Supporting a 9 kHz to 7.5 GHz frequency range and 110 MHz real-time bandwidth, it features advanced capabilities like 5G NR/LTE OTA testing, real-time spectrum analysis, pulse profile analysis, and GPS-synchronized indoor/outdoor mapping. This empowers technicians to optimize beam performance, troubleshoot interference, and accelerate network deployment with precision, while its integrated design enhances on-site testing efficiency and portability.

Key Features

  • Frequency Range 9 kHz~3.6/7.5 GHz
  • Real-Time Analysis Bandwidth 40/110 MHz
  • 5G NR OTA Measurement, multi-PCI and multi-beam analysis
  • LTE FDD and TDD OTA Measurement, multi-PCI analysis
  • Displayed Average Noise Level -165 dBm/Hz
  • Phase Noise -104 dBc/Hz at 1 GHz, 10 kHz offse
  • Standard Preamplifier, 8.4” Touch Screen, 2.5 hours Working Time

Product advantage

5G NR OTA Measurement

During 5G base station deployment, operators require precise validation of network quality and beam performance. The SHA860A’s 5G NR OTA mode demodulates signals to extract key parameters, including frequency, physical cell identity (PCI), SSB index, frequency error, and error vector magnitude (EVM) for the SSB portion, visualized via constellation diagrams. This functionality is vital for optimizing 5G Non-Standalone (NSA) deployments, ensuring seamless coordination between LTE and 5G networks.

LTE FDD/TDD OTA Measurement

The LTE OTA testing feature provides comprehensive demodulation metrics such as PCI, sector ID, cell group, frequency error, time offset, synchronization status, and power levels (PSS/SSS/CRS/PBCH), alongside EVM measurements and constellation diagrams. By analyzing signal quality, channel performance, and interference across multiple cells, technicians can implement targeted strategies to enhance network efficiency and user experience.
This function can demodulate cells. By measuring and analyzing the signal quality, channel quality and interference intensity of different cells, we can determine which cells have the most serious signal interference, and then take corresponding interference coordination measures to improve the communication quality and user experience of cells.

Real-Time Spectrum Analysis

With a 110 MHz real-time bandwidth and 300,000 FFT/s processing speed, the SHA860A captures transient signals as short as 3.51 µs at 100% Probability of Intercept (POI). Advanced tools like frequency mask triggering (FMT), Density, 3D, Spectrogram, and Power vs. Time (PvT) displays enable multi-dimensional analysis of complex signals, ideal for interference hunting and spectrum monitoring in dynamic 5G environments.

Cable and Antenna Test

Component faults compromise base station performance, leading to coverage gaps and signal strength degradation. The SHA860A streamlines maintenance with rapid single-port cable loss, return/insertion loss, VSWR, and distance-to-fault measurements. An optional upgrade adds 1-Path 2-Port vector network analyzer functionality, supporting S11/S21 testing, Smith chart displays, and a remarkable 114 dB dynamic range for precise amplitude/phase response analysis. 

Pulse Profile Analysis

The pulse analysis function featuring 10,001 measurement points to evaluate power, pulse transitions, and signal characteristics using multiple detection modes (positive/negative peak, sample, average, and conventional). This ensures rigorous validation of RF device performance in real-world conditions.

IQ Data Acquisition

Signal and spectrum analyzer with IQ data acquisition function is a common signal acquisition tool. Equipped with 1 GB RAM, 300 MHz sample rate, and 110 MHz bandwidth, the SHA860A provides a powerful combination of specifications, functions and portability for users collecting data in the field environment. Users can transmit and store IQ data via USB or LAN for offline analysis, so as to reproduce signals and visualize spectrum details with unmatched clarity.

Indoor/Outdoor Mapping

Beyond base station testing, identifying 5G/LTE coverage in specific areas is crucial. The indoor/outdoor mapping feature enables technicians to locate base stations, track antenna orientation/height, and identify weak coverage or high-interference zones. With data logging, playback, and ±0.01 ppm accuracy post-GPS lock, it simplifies network optimization in both indoor and outdoor environments.

Product parameter

Configure your instrument

Add to Compare ModelsFrequency RangeReal-time bandwidth analysisPhase Noise(typ.)Display Average Noise Level (DANL)Vector Network Analysis RangeFrequency Resolution Price  

Resources

Universal accessories
Created with Pixso. Created with Pixso.

Product
Description
USB Cable
USB Cable

USB-A to USB-B. Used to connect instrument to PC for communication.

Power cord
Power cord

The instrument comes standard with a power cord that conforms to the national standard of the user. Additional power cords in different regions can be purchased separately.

SHA860(850)A – Rechargeable Lithium Battery
SHA860(850)A – Rechargeable Lithium Battery
12V_AP_4A
12V_AP_4A

AC-DC Adapter, 12V, 4A (Power cord not included)

SHA860(850)A-Portable BAG
SHA860(850)A-Portable BAG
Quick Start-SHA860A
Quick Start-SHA860A

Quick guide included with the instrument.

Universal accessories
Created with Pixso. Created with Pixso.

Product
Description
N-BNC-2L
N-BNC-2L

2 GHz bandwidth, Length 0.7 m (27.6 inches)

Click to view the RF cable and connector manual

N-N-6L
N-N-6L

6 GHz bandwidth, Length 0.7 m (27.6 inches)

Click to view the RF cable and connector manual

N-SMA-6L
N-SMA-6L

6 GHz bandwidth, Length 0.7 m (27.6 inches).

Click to view the RF cable and connector manual

N-N-18L
N-N-18L

18 GHz bandwidth, Length 1.0 m

Click to view the RF cable and connector manual

N-SMA-18L
N-SMA-18L
SMA-SMA-18L
SMA-SMA-18L

18 GHz bandwidth, Length : 1000 + 10 (mm)

Click to view the RF cable and connector manual

UkitSSA3X
UkitSSA3X

Reflection bridge, 1 MHz to 2.5 GHz; 2 x N(M)-N(M)

Click to view the RF cable and connector manual

SRF5030T
SRF5030T

Three magnetic field near-field probes (5 mm, 10 mm, 20 mm) and one electric field near-field probe (5 mm) with frequency range of 300 kHz ~ 3 GHz and resolution of 5 mm, 10 mm, 20 mm are suitable for EMI radiation interference and intensity detection.

Click to view the calibration kit manual

F503FE
F503FE

Mechanical Calibration Kit, Type N – Female, Open (F), Short (F), Load (F), Through (F–F), 50 Ω, DC – 4.5 GHz

Click to view the calibration kit manual

F503ME
F503ME

Mechanical Calibration Kit, Type N – Male, Open (M), Short (M), Load (M), Through (M–M), 50 Ω, DC – 4.5 GHz

Click to view the calibration kit manual

F504FS
F504FS

Mechanical Calibration Kit, Type N – Female, Open (F), Short (F), Load (F), Through (F–F), 50 Ω, DC – 9 GHz

Click to view the calibration kit manual

F504MS
F504MS

Mechanical Calibration Kit, Type N – Male, Open (M), Short (M), Load (M), Through (M–M), 50 Ω, DC – 9 GHz

Click to view the calibration kit manual

F603FE
F603FE

Mechanical Calibration Kit, 3.5mm – Female, Open (F), Short (F), Load (F), Through (F–F), 50 Ω, DC – 4.5 GHz

Click to view the calibration kit manual

F603ME
F603ME

Mechanical Calibration Kit, 3.5mm – Male, Open (M), Short (M), Load (M), Through (M–M), 50 Ω, DC – 4.5 GHz

Click to view the calibration kit manual

F604FS
F604FS

Mechanical Calibration Kit, 3.5mm – Female, Open (F), Short (F), Load (F), Through (F–F), 50 Ω, DC – 9 GHz

Click to view the calibration kit manual

F604MS
F604MS

Mechanical Calibration Kit, 3.5mm – Male, Open (M), Short (M), Load (M), Through (M–M), 50 Ω, DC – 9 GHz

Click to view the calibration kit manual

Y504FS
Y504FS

Integrated Mechanical Calibration Kit, Type N – Female, Open (F), Short (F), Load (F), Through (F–F), 50 Ω, DC – 9 GHz

Click to view the calibration kit manual

Y504MS
Y504MS

Integrated Mechanical Calibration Kit, Type N – Male, Open (M), Short (M), Load (M), Through (M–M), 50 Ω, DC – 9 GHz

Click to view the calibration kit manual

F504TS
F504TS

Mechanical Calibration Kit, Type N – Male and Female, Open (M,F), Short (M,F), Load (M,F), Through (M–M, M–F, F–F), 50 Ω, DC – 9 GHz, with wrench W-191

Click to view the calibration kit manual

F604TS
F604TS

Mechanical Calibration Kit, 3.5mm – Male and Female, Open (M,F), Short (M,F), Load (M,F), Through (M–M, M–F, F–F), 50 Ω, DC – 9 GHz, with wrench 604-W01

Click to view the calibration kit manual

BAG-H2
BAG-H2

Portable bag

SHA860(850)A – Rechargeable Lithium Battery
SHA860(850)A – Rechargeable Lithium Battery
ANT-DA11
ANT-DA11

Contains amplifier handle and 10MHz ~ 200MHz antenna. Antenna gain 10dB (typical value); SWR <1:1.9 (typical value); 50Ω/N type, female; polarization direction horizontal and vertical.

ANT-DA12
ANT-DA12

Contains amplifier handle and 200MHz ~ 500MHz antenna. Antenna gain 10dB (typical value); SWR <1:1.9 (typical value); 50Ω/N type, female; polarization direction horizontal and vertical.

ANT-DA13
ANT-DA13

Contains amplifier handle and 500MHz ~ 8GHz antenna. Antenna gain 10dB (typical value); SWR <1:1.9 (typical value); 50Ω/N type, female; polarization direction horizontal and vertical.

ANT-GPS1
ANT-GPS1

GPS antenna, SMA(M), 100cm

All options
Created with Pixso. Created with Pixso.

Product
Description
SHA860-AMA
SHA860-AMA

Analog Modulation Analysis (SW): AM/FM/PM

SHA860-AMK
SHA860-AMK

Advanced Measurement Kit

SHA860-B1A
SHA860-B1A

Analysis Bandwidth 110 MHz

SHA860-BIAS
SHA860-BIAS

Vector Network Analysis

SHA860-CAT
SHA860-CAT

CAT antenna and cable measurement

SHA860-DMA
SHA860-DMA

Digital Modulation Analysis

SHA860-F2
SHA860-F2

SHA861A to SHA862A

SHA860-GPS
SHA860-GPS
GPS Receiver
SHA860-IQA
SHA860-IQA

IQ Data Acquisition

SHA860-LTE
SHA860-LTE

LTE TDD/FDD OTA Measurement

SHA860-MAP
SHA860-MAP

Outdoor/Indoor Map

SHA860-NR
SHA860-NR

5G NR OTA Measurement

SHA860-RTA
SHA860-RTA

Real-Time Spectrum Analysis

SHA860-VNA
SHA860-VNA

Vector Network Analysis

SHA860-F4
SHA860-F4

SHA863A is upgraded to SHA864A

SHA860-F5
SHA860-F5

SHA864A is upgraded to SHA865A.

Hide Created with Pixso.