9.Roll:
a)Supported Math and track cursors in Stop mode
b)Supported bandwidth limit
10.Webserver: supported inverted screenshot (according to the Image style setting in the Save menu)
11.Save/recall: File Manager: Supported to Select All; Supported to save all frames to a single file in Sequence mode
12.UI:Supported to specify Zoom region by drag a rectangle
13.Utility:Added English help; Supported password for screen saver
14. Fixed several bugs
a) When Log horizontal is used in FFT numbers are scrambled
b) Vertical axis of FFT optimized
c) Grid not aligned with numbers/wrong place with large offset
d)100BASE-T1 compliance test: displayed units of test result and judgment criteria are inconsistent
e) 100Base-TX and 1000Base-T: algorithm optimized
f) USB 2.0: compatible issue with USB IF recommended fixture
g) 1000BASE-T: transmission distortion test automatically executes without confirmation after completing one pair under the pairALL differential probe test
1.Optimize vector signal quality
2.HW Information displays the hardware serial number.
3.Remove “None” from the Custom filter type.
4.Added filter settings to ARB waveform settings.
5.Remove filter settings in ARB settings.
6.Added armed auto mode to ARB trigger.
7.The maximum number of multitone has been increased to 25001.
8.Supports playback of GSM, DAB, and WCDMA protocol waveforms.
9.Added automatic startup for SMB server and supports setting SMB server password.
10.Fixed several bugs
a)SCPI modulator attenuation type display instruction error.
b)Switching LF on the LF source page will not refresh the LF icon at the top.
c)TXT file playback error.
d)When playing txt and wdbin files, a local folder is generated in the root directory.
Fixed some bugs:
1. SCPI instruction configuration exception when inactive channel is set as trigger source.
2. Under the interpolation time base, CSV files need to save the original sampling points, not the interpolated points.
3. After recalling the settings file, sometimes the cursor settings are incorrect.
4. In tracking mode, using the SCPI command to change the source of an X cursor will cause the sources of X1 and X2 to change simultaneously.
5. After setting the reference level for FFT, power down and restart to restore the reference level error.
6. In the average sampling mode, when the time base is modified under a large time base, the waveform does not clear the old sampling points.
7. SCPI instruction reads FFT cursor, returns incorrect unit.
8. Sometimes UART decoding stop bit judgment error.
9. When the unit is mHz, the frequency value read by SCPI is in MHz units, which confuses uppercase and lowercase.
1.Display: Supported 100ms, 200ms, 500ms persistence;Supported large font;Optimized the display of custom probe attenuation in the channel description box
2.Fixed several bugs:
a)In Normal trigger mode after one minute the waveform will be refreshed automatically
b)In edge trigger mode Alternating can only trigger on rising edge or falling edge
c)In roll mode level of pattern trigger cannot be set
1.Modified the return of * OPT and added custom IDN and OPT
2.Added LXI
3.Add SCPI command recording function
4.Fixed some bugs
a) Resolve the issue of not reducing the option numbers of uses
b) Resolve the issue of incorrect power in certain situations
1. Support adjustment of cursor result display position.
2. Support displaying the average sampling count in the lower right corner of the screen.
3. Support knob acceleration function for cursor value and derivative step.
4. Support setting Math vertical offset and derivative step through the keypad.
5. Optimize trace colors after screen invert (C1 as yellow, C2 as green).
6. Fixed several bugs:
a) Issue where channel invert setting is not saved after reboot..
b) Issue with universal knob indicator light status error.
c) Issue when the menu is hidden, opening History or Search does not show the menu.
d) Issue when measure gate at the screen boundary, the device cannot be powered on after reboot.
e) Issue of missing prompt when adjusting parameters with knob in FFT split-screen mode.
f) Issue where reference label was displayed incorrectly when obscured by menu.
g) Issue of inaccurate AC measurement when inputting large offset AC signal.
Bug Fixes:
1. Fixed issue with Reverse Response Thru Calibration.
2. Fixed issue with log dialog.
3. Fixed issue with recalling state file by SCPI.
4. Fixed issue with abnormal power of SA function under specific conditions.
1. Fixed several bugs
a) Cannot exit from Bode plot in some case
b) Cannot detect active probes correctly when the probes are connected at power-on
c) “Set to 50% level” takes the scope frozen in some case
d) Sample rate is displayed incorrectly after reboot from Fixed Memory Length mode
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
When the EMI resolution bandwidth (RBW) is ≥ 30 kHz, the minimum measurable time can be set to 0.01 ms.
The maximum configurable value of EMI RBW/step can be set to 10, and the maximum dwell time can be set to 20 s.
Improve the measurement accuracy of the N dB marker.
Solved Issues:
Resolve the issue of incorrect unit display for the marker.
Resolve the issue of incorrectness in some SCPI commands.
Resolve the issue of screen flickering that may occur on some models during startup.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
When the EMI resolution bandwidth (RBW) is ≥ 30 kHz, the minimum measurable time can be set to 0.01 ms.
The maximum configurable value of EMI RBW/step can be set to 10, and the maximum dwell time can be set to 20 s.
Improve the measurement accuracy of the N dB marker.
Solved Issues:
Resolve the issue of incorrect unit display for the marker.
Resolve the issue of incorrectness in some SCPI commands.
Resolve the issue of screen flickering that may occur on some models during startup.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
When the EMI resolution bandwidth (RBW) is ≥ 30 kHz, the minimum measurable time can be set to 0.01 ms.
The maximum configurable value of EMI RBW/step can be set to 10, and the maximum dwell time can be set to 20 s.
Improve the measurement accuracy of the N dB marker.
Solved Issues:
Resolve the issue of incorrect unit display for the marker.
Resolve the issue of incorrectness in some SCPI commands.
Resolve the issue of screen flickering that may occur on some models during startup.
2. Measure:
a) Added item: UpperLower
b) Added Source: ZFx, ZMx
c) Supported zoom in the measure histogram
3. Cursors: Supported to hide Y cursors in track mode
4. Math:
a) Supported up to 8 traces
b) Added operators: Envelope, tan, atan, FFT Phase
c) FFT:peak added delta display; marker added ordering by number, amplitude and frequency
d) FFT:Added windows Blackma_Harris and Gaussian
e) Supported to hide traces
5. Analysis:
a) SignalScan added decode search
b) Eye Diagram: added Vpp measurement
6. REF: Supported to hide traces
7. Zoom:
a) ZFx supported to set horizontal scale independly; ZFx, ZMx supported to synchronize the display region with Zx
b) Supported to set Zx’ vertical scale with unified adjustment
8. Roll:
a) Supported decode in Stop mode
b) Supported Roll + Zoom in fast display mode
9. Prode: Supported CP150, HVD3106A; Supported to set external scaling of SAP2500D
10. Save/Recall:
a) Autosave supported to save pictures
b) Supported to save all channels’ data to a single file
c) FileManager:Supported to view a picture in full screen mode
11. Display:
a) Axis label supported to set the vertical label on center and right
b) Supported to change the font size
2. Math:
a) Added operators: atan, Fiter
b) FFT: added windows Blackman-Harris and Gaussian
3. Measure:
a) Added item: Bit Rate, Data Rate, UpperLower, △TimeMax、△TimeMin
b) Supported to limit the display digits of measure
4. Roll: Supported Math and decode in Stop mode
5. Webserver: supported inverted screenshot (according to the Image style setting in the Save menu); added Run/Stop button
6. Save/recall: Supported Auto Save; support “Select All” operation in FileManager
7. UI:Supported to specify Zoom region by drag a rectangle; supported movable channel label
8. Utility:Supported password for screen saver
9. SCPI: added command for △time; added command to hide right menu
10. Fixed several bugs:
a) To hide Y cursors in track mode
b) In ERES + Roll mode, head of the trace is incorrect
c) When saving a .mat file it is possible to lost the last 4 bytes
d) Issues on matching SCP current probes
1. Add DHCP function to IP addressing
2. Add Open Socket at LAN port 5025
3. Add over current protect function in a special case
4. Fix a crash fault when restoring settings
5. Modify the calibration arithmetic in 2-wire resistance
measurement 10 MOhm range
6. Add “ABORT BULK IN” ,”INITIATE CLEAR” features
to remote SCPI commands
1. Improve the UI.
2. Fix the bug in the trend chart.
3. Modify the number of file systems from 2 to 3 and copy some
configuration files to new location .This will reduce the chance of
a system crash.
4. Need to use transition software to update from old to new
version.
1. Add and optimize the manual calibration function
2. Solve the socket communication in multiple cycles of
open/close, may not respond to the problem
3. Fix the problem that the “READ” command does not
match the description in the programming manual
4. Fix the key test screen no prompt
5. Optimize the connectivity test buzzer response speed
issues
1.Long press the left button: one beep sounds,
and the prompt “CC mode prompt tone
disabled” plays.
Long press the left button again: two beeps
sound, and the prompt “CC mode prompt tone
enabled” plays.
1.This firmware is only compatible with
hardware version V6.1.
2.The MCU has been changed to GD32F427.
Firmware versions 1.01.01.02.XXX cannot be
upgraded.
1.Long press the left button: one beep sounds,
and the prompt “CC mode prompt tone
disabled” plays.
Long press the left button again: two beeps
sound, and the prompt “CC mode prompt tone
enabled” plays.
1. Fix: The UI was not updated in time when the power meter was pulled out.
2. Fix: GPIB Address can not be changed.
3. Fix: The mouse is hidden under VNC.
4. Fix: Some wrong SCPI commands were executed.
5. Optimize function with OCXO module.
6. Optimize power meter function.
1. Fix: In the custom mode, when save the state, some items are not saved.
2. Fix: Arb mode and pulse mode conflict. Now they can work simultaneously.
3. Fix: In Arb mode, there are some spurs, when On/Off the RF Mode button.
4. Fix: Some problems about LAN setting, VNC
1. Reduce the overshoot in the pulse function
2. Add pause function and the amplitude can be changed during pause status in
frequency step sweep mode.
3. Added some setting’s SCPI commands.
1. Added user manual calibration and verification function
(option).
2. Added the function that the number of vertical grid can be
set.
3. Added the function of supporting logarithmic display of
vertical coordinates.
4. Added point limit function
1.Add manual configuration of DC under TDR.
2.Add calibration overwrite function.
3.Optimize synchronization of external triggers for pulse
measurements.
Features and Enhancements:
1. Added Automatic Fixture Removal.
2. Added Noise Figure Measurement.
3. Added Power Meter Viewer Dialog.
4. Added support for cal kits with Sliding Load and Offset
Load.
5. Added support for HiSLIP communication protocol.
Bug Fixes:
1. Fixed a problem when changing IF bandwidth.
2. Fixed issue where changing directory in the File Browser
would cause GUI crash.
3. Fixed issue where multi-channel calibration would cause
crash.
4. Fixed issue where cal file would not correctly save or recall.
5. Fixed issue where sweep time would not estimate correctly
after adding a SA channel
6. Fixed issue with calibration type list display.
7. Fixed a bug where loading S2P file for 2-port de-embedding
would cause crash
8.Fixed issue with calibrating with a DATA-BASED
calibration kit.
9. Fixed issue with recalling CSV or SNP data files.
1. Add shortcut buttons at the toolbar.
2. Fix the stuttering problem when adjusting the brightness of
the grid in the waveform area.
3. Solve the problem of probabilistic crashes when opening
dialogs.
4. File storage shortcut keys support more types.
5. Support more power meters.
6. Add picture editing function to the screenshot dialog.
7. Adds peak reference function for bandwidth search.
8. Modify the contents of the Chinese and English help files
9. Modify the user receiver calibration process.
10. The input box will pop up automatically when using the
toolbar button to add Marker.
1.Solved the menu button is not updated when the electronic
calibration module is inserted or removed.
2. Fixed a bug that the touch screen may crash under some
cases.
3. Fixed an option installation bug.
1. Added spectrum analyzer option.
2. Fixed input bug in network configuration window.
3. Fixed mouse click input box crash bug.
4. Increased the touch-sensitive area of the DHCP checkbox.
5. Modified the policy when the DHCP request fails.
1. Added Frequency Offset function.
2. Optimized some functions of spectrum analysis.
3. Added status bar to display smooth status.
4. Added advanced mode for bandwidth search, support
frequency percentage bandwidth setting function.
5. Optimized the Marker->Delay algorithm.
Features and Enhancements:
1. Added Automatic Fixture Removal.
2. Added Noise Figure Measurement.
3. Added Power Meter Viewer Dialog.
4. Added support for cal kits with Sliding Load and Offset
Load.
5. Added support for HiSLIP communication protocol.
Bug Fixes:
1. Fixed a problem when changing IF bandwidth.
2. Fixed issue where changing directory in the File Browser
would cause GUI crash.
3. Fixed issue where multi-channel calibration would cause
crash.
4. Fixed issue where cal file would not correctly save or recall.
5. Fixed issue where sweep time would not estimate correctly
after adding a SA channel
6. Fixed issue with calibration type list display.
7. Fixed a bug where loading S2P file for 2-port de-embedding
would cause crash
8.Fixed issue with calibrating with a DATA-BASED
calibration kit.
9. Fixed issue with recalling CSV or SNP data files.
1. Add “PNG“ file type for screenshot.
2. Support TG in RBW less than 30 kHz.
3. Modify default TG output power, -20 dBm in spectrum ananlyzer mode and 0 dBm in
reflection measure mode, and some other TG issues.
4. Updating the format of “LIM“ file. After this firmware , the old limit files will not be
supported. You can recreate them through “EasySpectrum” free software easily.
5. After this firmware, do not support downgrade operation.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Add socket/telnet-scpi, you can operate remote control through LAN port without
NI-VISA installed. Please see SSA3000X‘s Programming Guide for more details.
3. Change two limit lines in different colours.
4. When quit from TG, stay in“Auto” sweep.
5. Lower some spurs when FFT.
6. Improve the stability.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Improved the stability of sweep and avg detect.
3. Fixed some bugs on sweep, frequncy counter and Log-Log scale.
4. Fixed some bugs on SCPI and the AMK option.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Fixed v1.2.8.5 bugs on Refl Mode.
3. Fixed v1.2.8.5 bugs on language and file
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X
has an earlier version, please update to V1.2.8.1 first and then proceed to
update to the latest version.
2. Fixed bugs on peak search and next peak.
3. Optimize SCPI commands for peak table, screenshot, etc.
4. Optimize the LOG X-scale for EMI test.
5. Optimize the Quasi-Peak detector accuracy for EMI test
Improvements:
• Optimize trace, marker, signal track, TG normalization,Reflection measurement in SA Mode
• Optimize web server UI
Solved Issues:
• Fixed video trigger fail, errors in Harmonic measurement in SA Mode
• Fixed spectrum amplitude error, meas error, waveform discontinue in MA Mode
• Fixed English help, system message
Improvements:
• Add Limit mask offset in SA mode
• TG Level adjustable in Reflection Meas
Solved Issues:
• Fixed AM and FM symbol rate error, Lpf coefficient error, in AMA mode
• Fixed Filter bandwidth error in DMA mode
• Fixed Freq counter error in SA mode
• Fixed Harmonic error in SA mode
• Help Display error
New Functionality:
• Update EMI option to a new EMI measurement mode
Improvements:
• Improve TG output harmonic performance
• Update Help file
Solved Issues:
• Fix ADC overload warning
• Fix Ch Power calculation bug in small span
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
This version con not be rolled back
• Fix TG switch error at small RBW
• Fix Help and Limit file lost when Factory reset
• Fix CNR calc error when no peak found
• Fix OBW result overflow
• Fix Harmonic calc error at 100Hz RBW
• Fix Reflection Open+Short calibration action
• Fix spectrum amplitude error in DMA mode
• Optimize EMI .csv file content to all signal list
• Optimize EMI peak search
• Optimize Auto cal process
• Add Peak search to Spectrum in DMA mode
• Fix TG switch error at small RBW
• Fix Help and Limit file lost when Factory reset
• Fix Auto open delay unit error in VNA mode
• Fix CNR calc error when no peak found
• Fix OBW result overflow
• Fix Harmonic calc error at 100Hz RBW
• Fix Reflection Open+Short calibration action
• Fix spectrum amplitude error in DMA mode
• Optimize EMI .csv file content to all signal list
• Optimize EMI peak search
• Optimize Auto cal process
• Add Peak search to Spectrum in DMA
It is strongly recommended to update to the latest
release because in some previous release exists
some serious bug which could cause the generator
never startup
1. Supported system recovery from the U-disk
2. Supported Rev.C hardware with Over Voltage
Protection
Fixed the abnormal display issue during start-up on
some units with previous releases. It is not
necessary to update to this version if the unit has
no such a problem.
1. Added statistic function in counter mode
2. Supported using method 2 from our “generating
mulitphase waveforms” application note (refer to
http://www.siglentamerica.com/prodcut-pxzl.aspx?id=9
0&tid=16&T=2) to synchronize 2 units of SDG2000X
3. Fixed some bugs
a) A bug in file system could cause the generator
never startup
b) DHCP does not run at power up
c) Channel lock phase can be wrong in modulation
sometimes
d) Error in calculation of frequency deviation in
counter mode
e) Instrument does not allow CH1 and CH2 to both
use the external input for the modulation source
simultaneously in tracking mode
f) Downward compatibility of .xml state file
g) Unable to delete files with uncommon character(s)
in their names
*Note:
NOTE: After being updated to this release, the generator cannot be backward to previous releases any more
1. Allow 0 Hz for CH Frequency In MOD Modes PM, AM,
DSB-AM, ASK, PSK
2. Allow MOD frequency > CH Frequency In MOD Modes
PM, DSB AM, ASK
3. Allow DSB-AM, AM MOD Modes In TrueArb Mode
4. Up Followed by Down Sweep Mode is Supported in
Linear Sweep (No Change for Log Sweep)
5. Added ARB waveform name to display, allowing user to
know what Arb waveform is loaded
6. Fixed some bugs
a) Arb Waveforms In DDS Mode Have One (Small)
Glitch Per Cycle
b) Built in Ramp waveform has a flat spot issue at the
rising slope zero crossing right at the SYNC pulse.
c) Power Up Last Does Not Remember
SRate/Frequency Setting
d) MOD Type = DSB AM Has Amplitude Issues
1. Changed the amplitude strategy of AM modulation: The
carrier stays fixed at the amplitude, regardless of the
modulation setting.
2. Increased the upper limit of Harmonics number from 10
to 16.
3. Supported Multi-Device Synchronization.
4. Supported Up followed by Down Sweep mode in Linear
sweep (no change for Log sweep).
5. Added an icon to indicate clock source is internal or
external.
Internal: External:
External and the clock is lost:
6. Changed the clock switch strategy: When the clock
source is set to External and no actual external clock
signal is being received, the clock source will not switch
to Internal automatically but the clock icon will
indicate that external clock is lost
7. Supported specifying Arb type by remote control when
the modulating waveform is Arb.
8. Optimized the UI of selecting built-in arbs
9. Supported changing the unit of amplitude without any
amplitude change by long pressing the “Amplitude”
softkey.
10. Added “User” option under “PowerOn Setting”.
11. Added “Normal” as a new UI color style.
12. Added memory space information in Store/Recall UI.
13. Optimized response of the universal knob
14. Added indicator for double function of the soft keys
=>
15. Removed the warning message when parameter is set
to a value beyond the limit
16. Fixed several bugs
a) [2017/04/07-92573] Digit changes when setting
delay of Pulse by the knob
b) Amplitude unit “dBm” is not remembered after a
reboot
1. Compatible with Rev.F hardware
2. Support trig dual channel separated when use mannul
trigger.
3. Support using another channel as the modulation
source
4. Support setting the output frequency after the
completion of sweep
5. Counter add fast measurement mode
6. Change the square waveform data used in square FM
modulation
1. Optimized TrueArb algorithm and added 3 types of
interpolation: sinc, sinc27 and sinc13
2. Optimized jitter performance of Square and Pulse
3. Optimized algorithm of Noise generating so the bandwidth
setting lower limit of Noise optimized from 80 MHz to 1
mHz
4. [2017/12/22-174663] Changed the clock switch strategy:
When the clock source is set to External and no actual
external clock signal is being received, the clock source
will not switch to Internal automatically but the clock icon
will indicate that external clock is lost
5. [2017/12/22-174663] Changed default state of 10 MHz
Out to “Disable”
6. Added Slave Delay option in Multi-Device Synchronization
function
7. Added indicator for double function of the soft keys
=>
8. Fixed the following bugs:
a) Crashes when downloading 20 Mpts waveform data
from the EasyWave program
b) Inaccurate burst delay
c) In TrueArb mode enabling AM with large amplitude
may trigger OVP
d) Switching the waveform from IQ to sine with large
amplitude may trigger OVP
e) Switching off the output on the SDG6kX only drops
the output level by approx 20 dB but does not
completely switch it off
1. Removed the warning message when parameter is set to
a value beyond the limit
2. Supported to copy/paste/delete folder in Store/Recall file
manager
3. Optimized initialization time when the waveform is
switched between IQ and other waveforms
4. Supported phase compensation in IQ mode
5. Fixed several bugs:
a) [2018/09/14-924144, 2018/09/14-937446] Signals
get interrupted upon timing-related change of the
settings in Independent mode
b) Anomaly on square/pulse waveform with some
setting
c) [2018/11/06-92208] Anomaly on arb waveform when
toggle the “ArbMode” from DDS to TrueArb and
back to DDS in Independent mode
1. Changed the upper limit of carrier frequency (sine) in
Burst mode from 300 MHz to 500 MHz
2. Added some missing SCPI commands
3. Fixed several bugs:
a) Messed up signal after switching from 500 MHz sine
to square in independent mode
b) Glitches when outputting pulses under certain
circumstances in independent mode
1. Allowed one channel to modulate the other
2. Supported Burst in TrueArb mode
3. Supported Burst Counter in Burst mode so the number of
burst trains can be set to > 1 when trigger source =
external or manual
4. Added an option to let the SDG start with activated
outputs
5. Added 50 ohm output impedance text in the UI
6. Able to remember the digit of a parameter that had been
modified
7. Fixed several bugs:
a) DDS interpolation bug
b) Switching on/off output causes random phase
deviation between channels in Track mode
c) Incorrect square/pulse waveform initialization in
some cases
d) Unable to store the level settings for noise
e) Unable to recognize the command MODE
PHASE-LOCKED
f) Freezing issue when being written a 20MB long file
with the EasyWaveX
g) The setting “BANDSET” with Waveform = NOISE
leads to inconsistent behavior on the Noise
Bandwidth of the output signal; The real-time noise
bandwidth on channel 2 is changed if an AM sine
modulation is switched on channel 1
h) Unable to install the IQ option before 30 trials run out
1. Measure: added new items UpLower, △TimeMax, △TimeMin
2. Math:FFT – added windows Blackman-Harris and Gaussian
3. Decode: Added SpaceWire, CANXL
4. Roll: Supported Math in Stop mode
5. Channel: in Eres mode to display the corresponding bandwidth
information in the descriptor box
6. Digital
a) Digital channels ASCII decoding requested
b) Optimized labels’ display
7. Save/Recall:
a) Supported AutoSave
b) File Manager: Supported to Select All
8. WebServer: supported inverted screenshot (according to the Image
style setting in the Save menu); added virtual front panel; added
Run/Stop button
9. UI:
a) Supported custom colors for XY trace
b) Supported to disable Time/Date display
c) Supported to specify Zoom region by drag a rectangle
10. Utility:
a) Supported password for screen saver
b) Key test: Supported to test the rotation direction of the encoders
11. Remote control:
a) a) added commands for counter
b) added commands for △time measurement
12. Fixed several bugs:
a) When saving inverted screenshot as JPG, PNG, trace color of
channels changes
b) SCPI commands don’t work in some cases setting horizontal
parameters
c) Phase measure doesn’t work in some case
d) In Eres mode, abnormal display on trace with 10Mpts length
13. Some SCPI issue on digital channels
1. Support SMB and NTP functions
2. Optimize the reading time for continuously switching gears at slow speeds
3. Repair the malfunction
a) BUG for incorrect readings when set to fast
b) The problem of manually setting the number of grids under the histogram failing
c) The issue of not saving time settings after restarting
d) The issue of failed first screenshot after inserting the USB flash drive
e) Cap automatic range failure issue under specific input
f) The problem of incorrect voltage readings when setting the input impedance to 10 Gohm is that selecting uA does not take effect in current mode
h) Abnormal reading function when dual display is turned on
Features and Enhancements:
1. Added Automatic Fixture Removal.
2. Added Millimeter Wave Measurement.
3. Added Noise Figure Measurement.
4. Added Power Meter Viewer Dialog.
5. Added support for cal kits with Sliding Load and Offset Load.
6. Added support for HiSLIP communication protocol.
Bug Fixes:
1. Fixed a problem when changing IF bandwidth.
2. Fixed issue where changing directory in the File Browser would cause GUI crash.
3. Fixed issue where multi-channel calibration would cause crash.
4. Fixed issue where cal file would not correctly save or recall.
5. Fixed issue where sweep time would not estimate correctly after adding a SA channel
6. Fixed issue with calibration type list display.
7. Fixed a bug where loading S2P file for 2-port de-embedding
would cause crash
8.Fixed issue with calibrating with a DATA-BASED calibration
kit.
9. Fixed issue with recalling CSV or SNP data files.
1. Add U disk recovery function.
2. Modify Hold function arithmetic.
3. Add the telnet SCPI function; port is 5024
4. Example: telnet 192.168.0.10 5024
1. Supports SMB and NTP functions.
2. Optimized noise after AZ is enabled.
3. Optimized noise after 100PLC is enabled.
4. Supports saving readings, statistics, and histograms in the scanner card function.
5. Supports relative value settings, statistics, and histograms in the dual display function.
6. Bug fixes
a) System crashes when entering the wrong password during recalibration.
b) Statistics occasionally show 0 in math.
c) Fixed an issue where overload values were recorded during probe-hold.
d) The digitizer would freeze at certain sampling rates and readings.
e) Device malfunctions occurred when using the scanner card’s universal remote control command function.
f) File path errors when browsing when holding readings.
g) Selecting uA in current mode did not work.
1. Linear frequency modulation increases waveform
display
2. Multi-tone supports independent control of
amplitude, phase and switch of each spectrum line
3. Compatible with SMBV100B remote commands
4. When the number of points in the marker file does
not match the number of points in the waveform file,
reset the marker to its initial value 5. Fixed several bugs a) Solve the problem of failure to load custom constellation map b) Solve the problem of abnormal linear frequency modulation waveform c) Solve the problem that the power meter flatness list filling is not effective
1. Support IQ waveform generated by customIQ of
SigIQPro;
2. Screenshot files support PNG and BMP formats;
3. MOD, SWEEP, BURST add RUN/Stop control function;
4. Support display of current output frequency during
frequency sweep;
5. Fixed the bug that the waveform is discontinuous when
the length of the sequence wave is not an integer multiple
of 16;
6. Enhance the sequence function, and the number of loops
of segment no longer occupies storage space multiple
times;
7. Delete the true arb mode of arb wave, and only keep the
DDS mode. The true arb mode is implemented by the
sequence (sequence with only one segment);
8. Solve the problem of abnormal output when the frequency
between 250MHZ and 300MHz during sweep;
9. Modify the default output polynomial of PRBS and support
programmable polynomial;
10. Sync output supports 50% duty cycle output mode;
11. IQ waveform information diaplay add data source
information;
12. Solve the problem of duty cycle is changed during
frequency change when square or pulse output;
13. Added a new DC output mode to solve the problem that
when changing the voltage, the output will jump to 0
before outputting. This method will reduce the output
accuracy;
14. Support amplitude sweep function.
1. Enhance the sequence function, and the number of
loops of segment no longer occupies storage space
multiple times;
2. Delete the true arb mode of arb wave, and only keep
the DDS mode. The true arb mode is implemented by
the sequence (sequence with only one segment);
3. Sweep adds step sweep mode;
4. Sync output supports 50% duty cycle output mode;
5. Optimize the operation response of the encoder;
6. Screenshot files support PNG and BMP formats; And
screenshot files are saved to the USB disk by default;
7. Added a new DC output mode to solve the problem
that when changing the voltage, the output will jump to
0V before outputting. This method will reduce the output
accuracy;
8. Modify the default output polynomial of PRBS and
support programmable polynomial;
9. Solve the problem of duty cycle is changed during
frequency change when square or pulse output.
1. Support decode after roll stop
2. Support decode hysteresis
3. Support Blackman-Harris and Gaussian window of FFT
4. Support XY split screen display
5. Support movable channel label
6. Support saving measurement statistics results
7. Remote reading acceleration(SERVICE->WAV ACC)
8. Support exFAT format for USB disk
9. Optimize UI
a) Add confirmation dialog for save To Default Key
b) Remove excess zeros in the axis labels
c) When the horizontal axis labels are too long, they will be displayed alternately up and down
d) Use real “µ” instead of small letter “u”
e) Optimize Keyboard Test
10. Fixed several bugs
a) When Beep enabled, physical buttons beep only until first move of any encoder
b) When the probe is not 1X and the vertical reference is Offset, the zoom area is unreasonable when changing the vertical scale
c) When the points is ≥10M, FFT has unreasonable spurious signals
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
⚫ Add measurement related functions, including:APSK function, Marker Band function, MA Record function and 200 Hz EMI RBW (only SVA1075X).
⚫ Add system related functions, including: local oscillator feedthrough self calibration, 10M out frequency accuracy Self-Calibration function and FTP function.
Improvements:
⚫ Optimize the auto-save function, add the auto-save switch and auto-save time function to Last Preset.
⚫ Add SCPI command, you can use the pscpi command to set/query the reference clock source used by the machine.
⚫ Improve the measurement function, including increasing the number of markers in VNA mode to 14; optimize the measurement accuracy of the channel power measurement mode to ensure higher measurement accuracy.
Solved Issues:
⚫ Fixed some known defects.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
⚫ Add measurement related functions, including:APSK function, Marker Band function, MA
Record function and 200 Hz EMI RBW.
⚫ Add system related functions, including: local oscillator feedthrough self calibration, 10M out
frequency accuracy Self-Calibration function and FTP function.
Improvements:
⚫ Optimize the auto-save function, add the auto-save switch and auto-save time function to
Last Preset.
⚫ Add SCPI command, you can use the pscpi command to set/query the reference clock
source used by the machine.
⚫ Improve the measurement function, including increasing the number of markers in VNA
mode to 14; optimize the measurement accuracy of the channel power measurement mode
to ensure higher measurement accuracy.
Solved Issues:
⚫ Fixed some known defects.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
⚫ Add measurement related functions, including:APSK function, Marker Band function, MA Record function and 200 Hz EMI RBW(only SSA3075XPlus).
⚫ Add system related functions, including: local oscillator feedthrough self calibration, 10M out frequency accuracy Self-Calibration function and FTP function.
Improvements:
⚫ Fixed some known defects.
1. Add a pop-up window when switching frequency
causes IQ mode to be turned off
2. New options: “SigIQPro-IEEE.802.11.a/b/g/n/ac”
3. Added linear frequency modulation function
4. Fixed several bugs
a) Solve the problem of inaccurate power when
turning on RF in IQ mode
b) Solve the problem of inaccurate power after turning on arb filtering c) Solve the problem of insertion failure after clearing the multi-carrier list d) Solve the problem of abnormal waveform after peak clipping/scaling
1. Solve the problem that the sync signal is
output when the channel is not turned on
2. After the sweep is completed, the output
frequency is modified to stay at the initial
frequency of the sweep
New Functionality:
Add user calibration for reference clock Improvements:
SA mode: optimize refresh efficiency
AMA mode: optimize AF smoothing effect
NF mode: exporting table results as .csv files
Add FTP switch function Solved Issues:
SA mode: align estimated scan time and regular scan time
BT mode: solve issues including Preset, EDR signal demodulation, and no response to quick operations
PN mode: solve issues including signal averaging failure and incorrect sweep width
NF mode: solve issues including calculation errors
RTSA mode: solve issues including no waveform in screenshots, peak failure,failure to save and load files, and missing reference offset
Add and modify SCPI commands:
1. Period cursor reading error (:CALCulate:MARKer:FCOunt:X?)
2. Query cursor function returns off (CALCulate:MARKer:FUNCtion?)
3. Setting external trigger command is inconsistent with programming manual(:TRIGger[:SEQuence]:SOURce)
4. Harmonic analysis command is missing to obtain each order harmonic frequency and power and obtain total harmonic distortion(:READ:HARMonics:AMPLitude:ALL? :READ:HARMonics:DISTortion?)
5. SA command reads back cent, low, high.Q results when obtaining NDB results(:CALCulate:MARKer:BANDwidth:RESult?)
1. Remove the knob acceleration function; Pressing the FINE key allows you to adjust the numerical value by selecting the digit, decile, and percentile, and the selected number will be highlighted.
1. Supported new AP models: SDS7804AP, SDS7604AP
2. Supported Enhanced Bandwidth on 4GHz and below models (Only applied to units which are produced with 1.1.9.1R1 and later FW)
3. Improved the response speed in the case of deep waveform length
4. Compliance test:
a) Added MIPI-DPHY
b) Added 2.5G/5G/10GBASE-T
c) For USB2.0, added Receiver Sensitivity test, and supported upgrading the FW of the fixture by the scope
5.Math:
a) Added operators Tan, Atan
b) Added operator FFTPhase
c) Added new windows Black-Harris and Gaussian for FFT
6. Decode: added CANXL
7. Optimized refresh speed in the case of Roll + Zoom
8. Eye Diagram: added Second order PLL for Clock Recovery
9.Save/Recall:
a) Supported to save all segments in sequence mode to one
single .mat file
b) Supported to save all channels’ data to one file
c) Supported Full Screen view of pictures in File Manager
10. Supported Wake-on-LAN (Some setting change is necessary. Contact
SIGLENT for detailed information)
11. WGEN: supported the case in which built-in and external generators
are both in use 12. Fixed several bugs
1. Fixed several bugs
a) Scope wont’t boot if set for DHCP and connected to LAN
without DHCP server
b) An “Acquiring” progress bar is showing up on 1 ms/div
instead of 100ms/div as before c) Remove BW Limit warning d) When FFT is set to certain frequency bands, such as 1kHz to 6kHz, meaningless axis labels are displayed (sweep mode is set to logarithmic)
1. Optimize reference code and add variable reference process
2. Set the target power setting range in power control to the indicator range of power
meter, and add the models of power meters of Keysight and RD
3. Solve some bugs
1. Supported multi-pulse waveform output.
2. Supported sequence playback.
3. Added new “step” sweep mode, and changed the
minimum sweep time to 5us.
4. Added the function of long pressing knob to save
screenshots.
5. Optimized knob response to solve the problem of
occasional code loss.
6. Added SCPI command for synchronous output of two
channels.
7. Added burst hold setting function for burst output.
8. Supported license installation by U-disk.
9. Supported MAC address display.
10. Solved the problem of output error under FSK modulation
when frequency above 300 MHz.
11. Solved the problem of occasional non-response for SCPI
command when connected by socket.
12. Solved the problem of system crash when importing large
CSV waveform file by U-disk.
1. Support decode after roll stop
2. Support decode hysteresis
3. Support Blackman-Harris and Gaussian window of FFT
4. Support XY split screen display
5. Support movable channel label
6. Support saving measurement statistics results
7. Remote reading acceleration(SERVICE->WAV ACC)
8. Optimize UI
a) Add confirmation dialog for save To Default Key
b) Remove excess zeros in the axis labels
c) When the horizontal axis labels are too long, they will be
displayed alternately up and down
d) Use real “µ” instead of small letter “u”.
9. Fixed several bugs
e) When Beep enabled, physical buttons beep only until first
move of any encoder f) When the probe is not 1X and the vertical reference is Offset, the zoom area is unreasonable when changing the vertical scale g) After NTP synchronization time, the history list time is wrong h) When the points is ≥10M, FFT has unreasonable spurious signals
1. Supported new low impedance passive probe SP6150A
2. Optimized SCPI command“WF”
3. FileConverter tool upgraded to version 3.5.8
4. Fixed several bugs
a) SCP5500 bandwidth displayed incorrectly
b) Scope + SCP5030A probe configuration is slow in Roll mode
c) PSRR measurement unexpectedly returns to bode plot
d) Some error in saving .mat files
New Functionality:
• Added EMI mode.
• Added SCPI commands to query files in a specified directory.
Improvements:
• Optimized the system information interface.
• Supports saving measurement results in txt format under AMA and DMA Mode.
• Optimized the calculation accuracy of Band Marker.
Solved Issues:
• Fix DHCP failure after IP conflict.
• Fix IQ collection.
• Fix map compression package reading error,and the playback points displaying error.
1. Supported new model: SDS7604A H12
2. Cursor: new cursor strategy, supporting multi cursors
3. Made Option 16LA Standard
4. Fixed several bugs
a) Stuck at splash screen after upgrade
5. Power off operation at start-up process brings the instrument to dead
1. Optimized the UI
2. Analysis: Added SignalScan, a powerful tool which can automatically
scan the acquired signals on the software according to the scan
conditions set by users, and mark them with red vertical lines or
rectangular boxes
3. Zoom
a) Supported ZFx (Zoom of Math trace) and ZMx (Zoom of Memory
trace)
b) Supported M1 and M2 modes (Acquire | Zoom). In M1 mode all
Zx channels share the same vertical scale while in M2 mode the
vertical scales are separately adjustable
4. Serial Decode:
a) Supported Math and Memory trace as source
b) Supported decode in Roll mode (Stop status)
c) Added Hysteresis
d) Added One Key Search (Recalling SignalScan to search the
specified item) for SPI, I2C and UART
5. Mask Test: Supported Math and Memory trace as source
6. Measure: added item UpperLower、△time1~4
7. Math
a) Supported Measure result (MeaX) as part of the formular
b) Added new operator: Envelope
c) FFT:Added new windows: Blackman_Harris and Gaussian
8. Channel: Supported movable label
9. WebServer: Added virtual front panel
10. Save/Recall: Added new item Project (including setup, waveforms and
screenshots)
11. SCPI:Optimized transport efficiency of command WAVE
12. Fixed several bugs
1. The flag font in CC state is changed to red.
2.In case of channel output,Press the aLL key to disable All ON/OFF output, and then press the All ON/OFF key to enable four out put channels.
1. Solve the problem of output desynchronization when
modulation depth/phase deviation/frequency deviation
is changed in channel tracking mode with AM/PM/FM
modulation
2. Solve the problem of abnormal output waveform when
switching back to the internal clock when the external
reference clock is abnormal.
3. Solve the problem of occasional abnormal output
waveform after power on
4. Add the function of long pressing store/recall to save
screenshots
Fixed several bugs
a) With low probability after start-up trace(s) not at Zero without
input
b) The color of “Math” LED not correct when F3 or F4 is activated
c) Chinese Traditional font issue
d) SMB connection fails when domain is used
e) IP setting issue
f) Scope dead when FW upgrade fails in the case that space at
/local not enough
1. Made Option 16LA Standard
2. Added new Analysis function: Serial Signal Test (Analysis | Serial
Signal Test)
3. Optimized UI
4. Supported USB-GPIB adapter
5. Fixed several bugs
a) IP setting issue
b) Scope dead when FW upgrade fails in the case that space at
/local not enough
c) “Bended” / “tilted” trace at small V/div
d) Math: Filter sample rate adaption cannot work
e) Frequency / Period measurements fail on certain waveforms
1. Optimize UI, change “on/off” to “On/Off”.
2. Solve the problem that some numbers from 200-223 cannot
be entered in the first byte of the IP address.
3. Standard software functions of FG and LA.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• VNA mode Ecal add Ecal Check, S11 Ecal, S21 Ecal. Add SCPI Command for Ecal Check
[:SENSe#]:CORRection:ECAL:CONFidence:CHECk. Add SCPI Command for PV test
[:SENSe#]:CORRection:ECAL:S11:PVTest, [:SENSe#]:CORRection:ECAL:S21:PVTest
Improvements:
• Display the exit command in Remote Control mode interface.
• SA/EMI/MA mode saves the current trace when saving user configuration
• SA mode auto tune does not change the amplitude Unit and Scale Type (Log/Linear)
• EMI mode exports Freq Interpoaltion (Log/Linear) when saving lmt file, and import the configuration when recalling the lmt file.
Solved Issues:
• Fix the problem of MA mode setting the SCPI command for filter type:
DDEMod:FILTer:MEASurement setting root raised cosine and raised cosine failed.
• Fix the problem that when the EMI mode does not have touch screen function, it is impossible to pull down to see more measurement results
• Fix the problem of unit error when the command DISPlay:WINDow:TRACe:Y:SCALe:RLEVel for setting the reference level in the RTSA mode does not contain units
• Fix the problem that when the RTSA mode’s Persistence state is infinite, using the command DISPlay:VIEW:DENSity:PERSistence can still set the Persistence time
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
Improvements:
• Display the exit command in Remote Control mode interface.
• SA/EMI/MA mode saves the current trace when saving user configuration
• SA mode auto tune does not change the amplitude Unit and Scale Type (Log/Linear)
• EMI mode exports Freq Interpoaltion (Log/Linear) when saving lmt file, and import the configuration when recalling the lmt file.
Solved Issues:
• Resolve the error issue of the SA mode TG waveform at 1.158GHz-1.168GHz.
• Fix the problem of MA mode setting the SCPI command for filter type:DDEMod:FILTer:MEASurement setting root raised cosine and raised cosine failed.
• Fix the problem that when the EMI mode does not have touch screen function, it is impossible to pull down to see more measurement results
1. Supports EMMC flash.
2. Add user-defined cold end compensation for temperature measurement.
3. After upgrading to version 1.02, you cannot return to version1.01
CAUTION: This release cannot be downgraded to previous releases.
1. Compatible with new hardware
2. Supported new probes: SCP5030A/SCP5150/SCP5500, SAP5000D
3. Trigger: modified the trigger strategy of /AND and OR trigger from FALSE-to-TRUE to TRUE-to-FALSE
4. Acquisition: modified the Average strategy in Single mode from acquiring one frame to acquiring averaged X frames (where X = Average count)
5. Optimized UI
6. Fixed several bugs
a) Freezing issue in Roll mode
b) Freezing issue relative to Stop-on-Search-Event in Search mode
c) In some case the scope does not update the waveform traces after a long time
New Functionality:
Add Phase Noise Measurement Mode
Add Noise Figure Measurement Mode
Add Pulse Measurement Mode
Add Blue Tooth Analysis Mode
Add AF spectrogram, SNR,Dist/Total,THD parameter analysis results in AMA
Mode
Add image browsing in SYSTEM
Solved Issues:
EMI mode Scan Only rescan with one less count issue
EMI mode sending command unable to rescan meter and Meas issues
1. Supported new probes: Siglent’s SCP5030, SCP5030A, SCP5150,
SCP5500 and LeCroy’s CP150, HVD3106A
2. Option to hide Memory and Math traces
3. Webserver: Screenshot can be directly copied and pasted
4. Fixed several bugs
a) Decode Threshold bug
b) NO persistence available with frames captured by SEQUENCE
1. Fixed several bugs a) Cannot exit from Bode plot in some case b) Cannot detect active probes correctly when the probes are connected at power-on c) “Set to 50% level” takes the scope frozen in some case d) Sample rate is displayed incorrectly after reboot from Fixed Memory Length mode
1.Cursor: Supported more cursors, and more flexible cursor combination
2. Measure:
a) Added item UpperLower
b) Supports to zoom in/out Histogram window
c) Supports two units for Histogram vertical axis: Percent, Count
3. Fixed several bugs
New Functionality:
• Add GNSS timing.
• Add the outdoor map downloader software EasyMAP.
• Add automatic screenshot and data store for LIMIT.
Improvements:
• UI Response improvement
Solved Issues:
• Fixed small RBW display.
• Fixed the abnormality of warm drifting calibration (compatible with old machines:calculating two problems with errors).
• When the DTF is solved to the feet format, the cursor returning unit is the problem of YARDS.
New Features:
• Kml recording function.
• Supports importing maps.
• Supports map feature under Channel Power measurement record playback in SA mode.
SCPI Commands:
• Added [ [:SENSe]:WAVeform:POINts? ] command to obtain the number of IQ sampling points.
• Added [ :FETCh:WAVeform? ] command to obtain IQ collected waveform data.
• Optimized Function:
• Optimized the Channel Power measurement refresh response efficiency in SA mode.
• Optimized VNC refresh efficiency.
Solved Problem:
• Fixed unstable frequency counter in SA mode.
• Fixed audio demodulation buzzing sound in SA mode.
• Fixed when trace is view in SA mode, a large error will be obtained when executing alignment.
• Fixed incorrect sequence number when harmonics obtain fundamental wave amplitude in SA mode.
1. This firmware must be upgraded from V1.2.8.1 or later, V2.X.X.X versions are not supported for upgrading this firmware. If your SSA3000X has an earlier version,please update to V1.2.8.1 first and then proceed to update to the latest version.
2. Fixed the error in setting RBW in EasySpectrum when using emi filter.
3. Optimize the settable range of Ref Level. When the maximum value of Correction data that is turned on is positive, the maximum settable Ref Level is correspondingly increased by an equal value.
4. Fixed TOI measurement marked error.
5. Fixed the issue of possible crash when using the scpi command
[:SENSe]:CORRection:CSET#:DATA? to read Correction data.
6. Optimize the use of command :DISPlay:WINDow:TRACe:Y[:SCALe]:RLEVel to set Ref Level. If no unit is specified, the current amplitude unit is used as the unit.
7. Fixed the issue where the command :CALCulate:MARKer#:Y? may read Marker amplitude value incorrectly when using Video Trigger.
8. Add Peak to Center command:CALCulate:MARKer#:MAXimum:CENTer
1. Add manual DC configuration under TDR
2. Calibrate and add overwrite function
3. Optimize synchronization triggered externally during pulse measurement
1. Support frequency hopping function
2. Built in EasyWaveX supports multi pulse function
3. Add the function of erasing user waveform files with one click
4. Solve the problem of system unresponsiveness when loading incorrect IQ waveform files
5. Solve the problem of occasional loss of locking when using OCXO
6. Solve the problem of loading network disk waveform files getting stuck
7. Fixed the bug of false alarms for overvoltage
Features and Enhancements:
1. Added Automatic Fixture Removal.
2. Added Power Meter Viewer Dialog.
3. Added support for cal kits with Sliding Load and Offset Load.
4. Added support for HiSLIP communication protocol.
Bug Fixes:
1. Fixed a problem when changing IF bandwidth.
2. Fixed issue where changing directory in the File Browser would
cause GUI crash.
3. Fixed issue where multi-channel calibration would cause crash.
4. Fixed issue where cal file would not correctly save or recall.
5. Fixed issue where sweep time would not estimate correctly after
adding a SA channel
6. Fixed issue with calibration type list display.
7. Fixed a bug where loading S2P file for 2-port de-embedding
would cause crash
8.Fixed issue with calibrating with a DATA-BASED calibration
kit.
9. Fixed issue with recalling CSV or SNP data files.
1. FFT: supported horizontal log axis
2. Channel: optimized strategy of adding a trace
3. Fixed several bugs
a) Bode plot: load and sweep settings not remembered; no virtual keypad for setting of some parameters
b) ARINC429 trigger not work on SDS6104 Pro
Solved some bugs
a) Resolve the issue of insufficient accuracy in saving
pulse train files
b) Solved the problem of DAC codeword overflow
c) Resolve the issue of flatness filling calculation errors
1. Solve the problem of slow USB drive detection during
startup
2. Solve the problem of outputting abnormal pulses during
burst mode
3. Add instructions for saving and reading status (XML)
files
4. Add the instruction to clear the statistics of the counter
Notice:
This firmware must be upgraded from v2.1.1.1 or later. If your analyzer has an earlier version, don’t use this FW to update.
Solved Issues:
• Fix the problem that the bandwidth of the emi filter in SA mode
• Fix the problem that setting the TG Level in SA mode may cause TG to have no output
• Fix the problem that the n dB Marker measurement results in SA mode are inconsistent with the OBW measurement results
• Fix the problem that there is an invalid frequency menu in Harmonic in SA mode
• Fix an issue where ‘micro’ relative units represented by ‘u’ were not recognized when reading files
New Functionality:
• Add AMA and DMA Mode
• IQ Acquisition in SA Mode
• Trace Record/Playback in SA mode
Improvements:
• UI Response improvement.
Solved Issues:
• Fixed align error
• Fixed data error Harmonic Measurement
• Fixed hung up after zero span calibration and enhancement response calibration in VNA mode.
• Fixed cont peak and gate sync error, and direction button error in CAT mode
• Fixed auto scale error in CAT and VNA mode.
Improvements:
Support EMI mode
VNC interface optimization
Solved Issues:
The default detection type of the third-order intermodulation in SA mode is changed to Pos
Fixed cursor readout update error when the readout type is not auto
10db higher signal amplitude under harmonic analysis
Harmonic analysis cannot modify the number of harmonics
MA mode time domain graph marker display unit corrected to dBV
Solved the problem that FTP cannot be used
1. Increased the data width of saved Average and ERES data from 8-bit
to 16-bit
2. Decode: added ARINC429
3. Math: added RBW display for FFT
4. Supported 12-hour time with AM and PM
5. Remote control:
a) Supported the USB-GPIB adapter
b) Added command supporting to query average count when
Acquisition = Average c) Added command supporting to enable/disable axis labels 6. Fixed several bugs a) Incorrect prompt when saving .csv with “Save all channels” to a U-disk as specified file name b) Channel ON / OFF labels are inconsistent 7. Freezing issue caused by command CURSor:XDELta?
1. Fixed bug that the output amplitude becomes larger when
upgrade from 6.01.01.36 to 6.01.01.36R3.
2. Optimize Self-calibration algorithm and open selfcalibration function in UI.
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• Add PM demodulation in MA mode
• The time of analog demodulation in MA mode is adjustable
Improvements:
• Add SCPI commands in MA mode:
Set the scan time: [:SENSe]:SWEep:TIME
Set the demodulation type: ADEMod:STYLe (new parameter is PM)
Get AM parameters: FETCh:AM#?
Get FM parameters: FETCh:FM#?
Get PM parameters: FETCh:PM#?
• Add system SCPI command:
*OPC for EMI mode
Exit remote status: SYSTem: LOCal for all mode
Solved Issues:
• Fix the problem that the bandwidth of the emi filter in SA mode
• Fix the problem that setting the TG Level in SA mode may cause TG to have no output
• Fix the problem that the n dB Marker measurement results in SA mode are inconsistent with the OBW measurement results
• Fix the problem that there is an invalid frequency menu in Harmonic in SA mode
• Fix the abnormality of the first scan in EMI mode
• Fix the problem that setting rbw may crash when qpd is not enabled in EMI mode
• Fix an issue where ‘micro’ relative units represented by ‘u’ were not recognized when reading files
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• Add ECal in VNA mode
• Add three new formats in VNA mode: Unwrap Phase/Real/Imaginary
• Add Z Reflection in VNA mode
• Add PM demodulation in MA mode
• The time of analog demodulation in MA mode is adjustable
Improvements:
• Add SCPI command in VNA mode:
Set the format Unwrap Phase/Real/Imaginary:
CALCulate#[:SELected]:FORMat adds three new parameters for UWPH/REAL/IMAG Set Z Reflection:
CALCulate#:TRACe#:CONVersion:FUNCtion OFF/ZREFlection Get the marker y value for Phase format with unwrap phase value:
CALCulate#:FSCan:MARKer#:Y?
Add SCPI commands for Calibration:
Select Open Calibration [:SENSe#]:CORRection:COLLect:METHod[:RESPonse]:OPEN
Select Short Calibration [:SENSe#]:CORRection:COLLect:METHod[:RESPonse]:SHORt
Select Enhance calibration [:SENSe#]:CORRection:COLLect:METHod:ENHAnced
Select Through Calibration [:SENSe#]:CORRection:COLLect:METHod[:RESPonse]:THRU
Select 1 Port Calibration[:SENSe#]:CORRection:COLLect:METHod:SOLT1
• Add SCPI commands in MA mode:
Set the scan time: [:SENSe]:SWEep:TIME
Set the demodulation type: ADEMod:STYLe (new parameter is PM)
Get AM parameters: FETCh:AM#?
Get FM parameters: FETCh:FM#?
Get PM parameters: FETCh:PM#?
• Add system SCPI command:
*OPC for EMI mode
Exit remote status: SYSTem: LOCal for all mode
Solved Issues:
• Fix the problem that the bandwidth of the emi filter in SA mode
• Fix the problem that setting the TG Level in SA mode may cause TG to have no output
• Fix the problem that the n dB Marker measurement results in SA mode are inconsistent with
the OBW measurement results
• Fix the problem that there is an invalid frequency menu in Harmonic in SA mode
• Fix the problem that the SCPI command: READ:ADEMod? would return an invalid value when
reading the analog demodulation measurement results in MA mode
• Fix the abnormality of the first scan in EMI mode
• Fix the problem that setting rbw may crash when qpd is not enabled in EMI mode
• Fix the problem of wrong reset when switching continue/single in RTSA mode
• Fix the problem that the 3D Spectrogram in RTSA mode will be abnormally full when pressing
pause under continuous scanning
• Fix an issue where ‘micro’ relative units represented by ‘u’ were not recognized when reading
files
1. Add and optimize the manual calibration function
2. Solve the socket communication in multiple cycles of open/close, may not respond to the problem
3. Fix the problem that the “READ” command does not match the description in the programming manual
4. Fix the key test screen no prompt
5. Optimize the connectivity test buzzer response speed issues
1. Eye Diagram: supported 100Base-T1 (PAM3)
2. SCPI: Supported Search
3. Supported USB-GPIB
4. Fixed several bugs
a) DY-WTFK-202203165613:Spectrum menu after installing
b) DY-WTFK-202209237014: Scope restarts acquisition after few
seconds when stopped
c) DY-WTFK-202207076348: Filter settings way off in special
acquisition modes
d) DY-WTFK-202209237015: Zone trigger doesn’t work at some
input frequencies
1. Compatible with Rev.G hardware
2. Fix the bug that the system does not respond when there is no operation for a long time after the counter is turned on
8.1.16 6.1.33/6.1.37R10 Yes
8.1.11 6.1.33/6.1.37R10 No
8.1.9 6.1.33/6.1.37R10 No
8.1.8 6.1.33/6.1.37R10 No
Update instructions
Important!
Because 6.1.33 fixed a bug with self- calibration for each channel. Please perform a self-calibration if the machine is updated to 6.1.33 (or higher)
Very important!
Optimized communication between SDS1xx4X-E and SLA1016. If the SDS1xx4X-E will be upgraded to this version (or higher), the SLA1016 MUST be upgraded to 8.1.16 (or higher) first.
Very important!
Because 6.1.20R1 fixed a bug with self- calibration for each channel, immediately perform a self-calibration if the machine is updated to 6.1.20R1 (or higher)
1. Optimized UBOOT
2. Some bug fixes
h) Solves the problem that scope id is sometimes unreadable
i) Resolved the problem that Pulse Out still has output after
pulse modulation is turned off
j) Solve the problem of false triggering of scanning trigger
1. Add user manual calibration and verification function (optional)
2. Increasing the number of vertical grids allows for the setting of functions
3. Add vertical axis support for logarithmic display function
4. Add point limit function
1. Fix the bug of pulse output error under specific
configuration
2. Support amplitude sweep function
3. Support the adjustment of channel skew
4. Support multi-file operation in the file manager
5. The digital channel does not support sequence output
6. Optimize the storage strategy of waveform data in
sequence playback
7. Support the playback of bin files exported by the
oscilloscope containing multiple frames
8. The PRBS rate up to 625Mbps
9. Fix the bug of abnormal signal output during waveform
switching
1. Force trigger strategy changed (same as SDS2000X HD)
2. Save/Recall
a) Supported to save all sequence segments
b) Supported Auto Save
3. Fixed several bugs
a) Cannot communicate with the SDG2000X and SDG7000A over
USB in Bode Plot
b) Random +/-200 ps skew between channels after power/reboot
cycle
c) [Power analysis] – Switching losses – Error in calculations
d) FFT wrong vertical scale
e) Memory channel trace always on top
1. Measurement enhancement – Added setup/hold time: tsu@R, tsu@F,
th@R, th@F
2. Optimized UI
3. Added SCPI commands for Measure Cursors and clearing measure
items in Simple mode
4. Supported LXI (only with the Uboot-OS Version 5.4)
5. Supported time zone setting
6. Fixed several bugs
a) Webserver doesn’t show instrument UI if the scope reboot with a
wireless mouse connected
b) Incorrect “Recall”icon in the File Manager
c) Scope freezes with AWG enabled and measure cursor on rise
time
d) IP setting of AWG in Bode Plot not remembered after reboot
e) Network storage only works for SMB1.0
f) MEAS:SIMPle:ITEMsOVSN,ON does not work as expected
g) Roll time incorrect at 1ks/div and 20kpts
h) Raw data not consistent in x and sinx/x interpolation modes
i) Math: Dx parameter of Derivation cannot be increased by
universal control
j) Incorrect FFT sample rate
1. Fixed the bug that startup occasional failures
2. Fixed the bug of burst sync output exception
3. Fixed the bug that may not output when switch
the waveform after the burst is turn off
1.This firmware is only compatible with
hardware version V6.1.
2.The MCU has been changed to GD32F427.
Firmware versions 1.01.01.02.XXX cannot be
upgraded.
1. This firmware only supports SPD3303X/X-E with hardware version 6.1
Note:
A、 Machines with hardware version V6.1 do not support rolling back to previous firmware versions
B、 Machines with hardware version
2. Released EasyPower (P20 version) that matches it
1.Change some user interfaces and operation methods
2.SET key changes to V/I function in main windows.
3.Optimize some features in list’s setup/save/web menus .
Note: This release cannot be downgraded to former releases.
1. Math: added filter operator
2. Supported to save waveform as Memory traces, which store the raw
data instead of the screen data (as Ref does), and can be source of
Measure/Math etc.
3. Measure: improved the AIM limit from 1,000 to up to 65,000 (AIM limit:
the upper limit of horizontal parameters measure statistics in one
frame )
4. Optimized intensity display of math traces.
5. Added support for mouse wheel when using a mouse
6. Supported CP030 current probe (with LPA10 adapter)
7. Eye Diagram: 100Base-TX signal supported
8. Trigger: Pattern trigger strategy changed
9. Power Analysis:
a) Supported MOSFET SOA (Safe Operating Area)
b) Bigger table size
10. Fixed several bugs
a) Moving the traces by gestures may cause the scope to freeze
b) [Bode Plot]Vertical Ref.level manual setting is partially bad
c) [Measure]Track plot – not working well in general
d) [Power Analysis]Current harmonics forgets table/bar view
e) Waveform Capture Rate breakdown at 20 ns/div
f) Measurements skip buffers in history mode
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
• Optimize the Ref level and Att couple
• Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
• Add Cable Atten to correct cable loss in DTF Mode
• Add .trc file in EMI Mode
• Add .lic file auto scan
Solved Issues:
• Fix the false signals in density view in RTSA mode
• Fix pi/4 DPSK 和 pi/8 DPSK decode errors in MA mode
• Fix calibration error when port extension on in VNA mode
• Fix fft frequency error in narrow span in SA mode
• Fix trace avg calculation error in SA mode
• Fix the zero sweep type when fft in SA mode
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
⚫ Optimize the Ref level and Att couple
⚫ Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
⚫ Add Cable Atten to correct cable loss in DTF Mode
⚫ Add .trc file in EMI Mode
⚫ Add .lic file auto scan
Solved Issues:
⚫ Fix pi/4 DPSK 和 pi/8 DPSK decode errors in MA mode
⚫ Fix calibration error when port extension on in VNA mode
⚫ Fix fft frequency error in narrow span in SA mode
⚫ Fix trace avg calculation error in SA mode
⚫ Fix the zero sweep type when fft in SA mode
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
Improvements:
• Optimize the Ref level and Att couple
• Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
• Add .trc file in EMI Mode
• Add .lic file auto scan
Solved Issues:
• Fix pi/4 DPSK 和 pi/8 DPSK decode errors in MA mode
• Fix fft frequency error in narrow span in SA mode
• Fix trace avg calculation error in SA mode
• Fix the zero sweep type when fft in SA mode
Fixed the problem: The skew of the two ADCs is not accuracy for hardware of 09 version (System Status shows Hardware Version: 09-xx). The other hardware version has no this problem.
1. Fixed the problem: The skew of the two ADCs is not
accuracy for hardware of 09 version (System Status shows
Hardware Version: 09-xx). The other hardware version has
no this problem.
1. Add LXI functionality
2. Change FTP transmission to encrypted transmission
3. Fixed some bugs
d) Solved the problem of incorrect calculation of sweep points
when the starting frequency of the sweep list is greater than
the ending frequency
e) Resolve the issue of sometimes incorrect reference code
settings
f) Resolve the issue of unordered flatness list
g) Solve the problem of functional buttons not working in
certain situations
Compatible with new hardware (hardware version: 04-xx).
Note:
This is a firmware compatible with new hardware. No feature or specification difference between it and 1.3.9R6. It’s not necessary to upgrade it from 1.3.9R6 to this release.
This release cannot be downgraded to former releases.
1. Channel: two custom probe ratio options supported
2. Fixed several bugs
a) Bode Plot draw error (missing draw)
b) Bode Plot – Very slow, nearly stuck, with some signal levels
c) Counter – totalizer not showing all numbers
d) Counter (time period) shows incredible numbers
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
Added Ext Trigger Delay from 0-10 seconds in SA Mode
Added Limit in Log mag and Lin mag format;
Added calibration average;
Added s1p touchstone file save in VNA mode
Improvements:
VNA sweep points up to 10001; Scale down to 0.001 in Smith chart;
MA Filter type Nyquist change to Raised Cosine to align SCPI command; improve filter performance in low frequency
EMI RBW/Step from 1 to 3
Solved Issues:
SA mode:
Fixed the difference between marker and peak and marker style;
Fixed Center Freq error; Fix limit fail to stop error;
Fixed Auto frequency error;
Fixed In normalization, auto re-normalized after any setting changes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• Add Ext Trigger Delay from 0-10 seconds in SA Mode
• Add Limit in Log mag and Lin mag format; add calibration average; add s1p touchstone file save in VNA mode
Improvements:
• VNA sweep points up to 10001; Scale down to 0.001 in Smith chart;
• MA Filter type Nyquist change to Raised Cosine to align SCPI command; improve filter performance in low frequency
• EMI RBW/Step from 1 to 3
Solved Issues:
• SA: Fixed the difference between marker and peak and marker style; Center Freq error;Limit fail to stop error; Auto frequency error; In normalization, auto re-normalized after any setting changes
• VNA:Fixed Phase error; STA file saving error; CSA file loading error; S21 calibration error; Enhanced calibration error
• RTSA: Fixed continue peak preset error; freq step error
• EMI: Fixed frequency offset error; saving std lim path error
• Web browser: Fixed change IP error, Login error after changing password
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version,
please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
• Add Ext Trigger Delay from 0-10 seconds in SA Mode
Solved Issues:
• SA fix the difference between marker and peak and marker style; Fix Center Freq error; Fix
limit fail to stop error; Fix Auto frequency error; In normalization, auto re-normalized after any
setting changes
• EMI frequency offset error; saving std lim path error
• Web browser cannot change IP, and cannot login after changing password
Fixed several bugs
a) Unexpected skew between channels after Stop in Roll mode
b) Some trigger setting with dual-level may lead the scope not to
start-up properly
Fixed several bugs
a) When selecting the option screen the scope hangs
b) Wrong FFT frequency when memory depth > 10 Mpts
c) Incorrect network storage path leads the scope to hang
c) Added parameters: Positive Slope and Negative Slope
2. Display:
a) Supported to display axis label
b) Auto hide menu setting increased to 10 seconds
c) Added “Hide” button in the fast menu of channel for quickly hiding
trace
3. Save/Recall:
a) Supported network storage
b) Supported to Print only grid area
c) Supported to save FFT result
d) Updated the File Manager
4. Bode Plot:
a) The maximum generator amplitude changed from 6Vp-p to
24Vp-p
b) Supported single sweep
5. Horizontal: Time Zero strategy updated – time zero changed from
center display to trigger position.
6. Acquisition: Deleted some unnecessary clear operations on the history
buffer
7. Updated Russian menu
8. Supported setting Cursors by virtual keypad
9. Fixed several bugs
a) Decode failure occurs on last nibble or byte
b) The “STL?” query issue in AWG function
c) If persistence is enabled, and you change the trigger setting,
persistence will be switched off
d) Decode list can’t go higher than item #2
e) Decode format is reset to “binary” when recalling stored settings
f) Sequence capture does not work with serial trigger from digital
channel
g) ERES 0.5-bit works for ERES(C1), but not for ERES(F1)
h) The icons for rise and fall time in the Measure Select screen are
reversed
i) When switching the attenuator, the message “Zone is too small”
appears
j) After shutting-down the scope and rebooting not all settings are
restored
k) Bode plot abnormal when Sequence is enabled
l) SENT decode: tolerance not functional
m) SENT decode: only display CRC segment but no calculation on
the CRC checksum
n) SENT decode: The Short Serial data is NOT decoded if only 16
frames are sent. If a 17th frame follows, the data is decoded
o) SENT decode: Changing the horizontal time/div affects the ability
to decode.
p) Save/recall: Number of digits of time stamp is not enough in the
long period
q) Infinite persistence not works after switching between 8-bit and
10-bit
r) Tolerance of UART decode too strict
s) FFT max. scale is unrealistic
1. Added data logger featuring Sample and Measurement Logger functions
2. Added counter function
3. Added Labels
4. Added NTP (Network Time Protocol) and Time Zone. Also requires OS update to SDS1xx4X-E_OSV2 which is located on the SIGLENT product webpage. The OS Update Instructions is also included SDS1xx4X-E_OSV2.zip
5. Modified negative or positive of horizontal delay: Time zero is in trigger. Before trigger, time position is -time (negative delay relative to trigger) and after trigger is +time (positive delay relative to trigger)
6. Fixed a bug with Bin2CSV for ROLL mode
7. Rebuilt Bin2CSV to File Converter which can also convert data logger file to CSV.
8. Fixed a bug: some case there is a blue line on decode bus
9. Fixed a bug with saving hex MSO CSV file
10. Fixed a bug: After rebooting , Bode Plot cursor can’t be moved
11. Fixed a bug: fine adjusting with customer probe
1. Added data logger featuring Sample and Measurement
Logger functions
2. Added counter function
3. Added Labels
4. Added NTP (Network Time Protocol) and Time Zone. Also
requires OS update to SDS1xx4X-E_OSV2 which is located
on the SIGLENT product webpage. The OS Update
Instructions is also included SDS1xx4X-E_OSV2.zip
5. Modified negative or positive of horizontal delay: Time
zero is in trigger. Before trigger, time position is -time
(negative delay relative to trigger) and after trigger is
+time (positive delay relative to trigger)
6. Fixed a bug with Bin2CSV for ROLL mode
7. Rebuilt Bin2CSV to File Converter which can also convert
data logger file to CSV.
8. Fixed a bug: some case there is a blue line on decode bus
9. Fixed a bug with saving hex MSO CSV file
10. Fixed a bug: After rebooting , Bode Plot cursor can’t be
moved
11. Fixed a bug: fine adjusting with customer probe
12. WiFi supported Spaces and Special Characters
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an
earlier version, please update to V1.2.8.1 first and then proceed to update to the
latest version.
2. Update the measurement result of MARKER immediately when changing its
parameters, instead of after the trace sweep ends.
3. Improve the stability of TG
1. Add the scan card setup save&recall function.
2. Optimize the slot time of the channel switching of scan card.
3. Optimize flash R&W design.
4. Fix some UI & SCPI bugs.
1. Add the scan card setup save&rcall function.
2. Optimize the slot time of the channel switching of scan card.
3. Optimize flash R&W design.
4. Fix some UI & SCPI bugs.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
2. Fixed the LOG scale sweep time and display error
3. Fixed the trace file .trc load and display error
4. Improve the stability of TG
5. Add peak excursion require command:CALCulate:MARKer:PEAK:EXCursion?
Add sweep state require command:TRACe:SWEep:STATe?
Add N dB Bandwidth left and right frequency require command
:CALCulate:MARKer*:BANDwidth:RLEFt?
:CALCulate:MARKer*:BANDwidth:RRIGht?
1. Fixed some crash fault about U disk save &recall.
2. Fixed some bugs about “acquire” function.
3. Improve the trend display function.
4. Fixed some bugs about communication with easysdm
This version con not be rolled back
• Fix TG switch error at small RBW
• Fix Help and Limit file lost when Factory reset
• Fix CNR calc error when no peak found
• Fix OBW result overflow
• Fix Harmonic calc error at 100Hz RBW
• Fix Reflection Open+Short calibration action
• Fix spectrum amplitude error in DMA mode
• Optimize EMI .csv file content to all signal list
• Optimize EMI peak search
• Optimize Auto cal process
• Add Peak search to Spectrum in DMA mode
Notice:
This firmware must be upgraded from V2.1.1.1.12a or later. If your SVA1000X has an earlier
version, please update to V2.1.1.1.12a first and then proceed to update to the latest version.
⚫ Fix the VNA option license error on some SVA1015 and SVA1075 units
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the response in RTSA
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix ADC overload warning error, and time unit error in Calibration in VNA Mode
• Fix amplitude error in DMA Mode
• Fix the frequency band downgrade to 3.2GHz on some units
Fix upgrade failure issue
Notice:
This firmware must be upgraded from V2.1.1.1.12a or later. If your SVA1000X has an earlier
version, please update to V2.1.1.1.12a first and then proceed to update to the latest version.
New Functionality:
⚫ Add EMI filter in SA for EMI option
Solved Issues:
⚫ Optimize the TG flatness and control procedure
⚫ Optimize Help
⚫ Fix Correction, .csv file, add peak numbers to 20 in EMI mode
⚫ Fix ADC overload warning error, and time unit error in Calibration in VNA Mode
⚫ Fix amplitude error in DMA Mode
Fix upgrade failure issue
1. New serial protocols supported (optional):
a) SENT, trigger & decode
b) Manchester, decode only
2. Measurement enhancement:
a) Supported user-defined thresholds (Upper, Middle and Lower):
Measure | Config | Threshold
b) Added items: +Area@AC, -Area@AC, Area@AC, AbsArea@AC
3. Math: added new operator – Interpolate
4. Display:
a) Supported selectable color for traces: Display | Color Setting
b) Supported floating menu so that the waveform is not compressed
horizontally when the right-side menu is displayed: Display | Menu
Style
c) Supported to show bandwidth information on the channel
descriptor box
5. Save/Recall:
a) Added option “Save all channel” for csv file
b) Supported to save math traces (except FFT)
6. Bode Plot:
a) Optimized scan speed
b) Fixed unexpected glitch issue
7. Supported serial trigger as source of the frequency counter
8. Unlocked zoom in stop mode for Roll
9. Supported trigger Default or AutoSetup operations by pressing
corresponding button twice
10. Fixed several bugs
a) Some vertical measurement error in roll mode
b) Missed peak marker in FFT two-tone test
c) AWG problem of importing the arb file from a U-disk
d) Whenever the screen is touched, the pass/fail statistics is reset to
zero
e) SPI data value setting issue using virtual keypad
11. Compatibility issue between WebServer and latest Chrome/Edge
browsers
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
2. Fixed the problem unit in TG and the UNCAL condition
3. Fixed the AVG detector in frequency LOG scale
4. Fixed the display error with long file name
5. Fixed some SCPI commands
6. Fixed the beeper switch
7. Fixed the .cor file error when recalling it
8. Add Limit mask offset in frequency and amplitude
1. Supported to hide analog traces
2. Added function expression information to the math box
3. Optimized AWG DC output accuracy at +/-3V
4. Frequency counter supported to count serial trigger events
5. Fixed several bugs
a) Incorrect cursor horizontal label for FFT traces
b) 2-channel 100MHz model cannot be upgraded to 350MHz
c) FRFR measure invalid from Roll to Stop
d) Unexpected behaviors when probe attenuation factor is not 1x
e) Some bugs in PA
1. Added support for the SAG1021I USB Isolated AWG Module Hardware
2. Fixed the bug: Sometimes PNSU command returns invalid value (Need referring to the latest Program Guide)
3. Added 9 data bits for UART decoding
4. Fixed the bug of UART decoder with some special settings
5. Increased baud rate of UART trigger from 5 Mbps to 20 Mbps
6. Fixed the bug: The command ‘WF? DAT2’returns error length of waveform when digital is enable
7. Fixed the bug: CSV file of waveform has no indication of the trigger point in the data
8. Fixed the bug: After repowering all FFT markers are on just one peak
9. Fixed the bug: After repowering, signal level of CAN trigger can’t be recalled
Fixed a few SCPI Commands error——MATH: CURSOR_VALUE? C3:INVERT_SET? is missing HISTORY_LIST? is missing DIGITAL:LOW8_SWICHT, typo in name C5:COUPLING? typo in name
11. Fixed the Bode Plot bug: Sometime there isn’t enough delay after the scope switches timebase values before it tries to take a measurement
12. Fixed the bug : Matlab can’t import 14 M Matlab waveform files
13. Fixed the bug:‘WF?’command ignores the length set by ‘WFSU’ for digital
1. Added support for the SAG1021I USB Isolated AWG
Module Hardware
2. Fixed the bug: Sometimes PNSU command returns invalid
value (Need referring to the latest Program Guide)
3. Added 9 data bits for UART decoding
4. Fixed the bug of UART decoder with some special
settings
5. Increased baud rate of UART trigger from 5 Mbps to 20
Mbps
6. Fixed the bug: The command ‘WF? DAT2’returns error
length of waveform when digital is enable
7. Fixed the bug: CSV file of waveform has no indication of
the trigger point in the data
8. Fixed the bug: After repowering all FFT markers are on
just one peak
9. Fixed the bug: After repowering, signal level of CAN
trigger can’t be recalled
10. Fixed a few SCPI Commands errors:
MATH: CURSOR_VALUE?
C3:INVERT_SET? is missing
HISTORY_LIST? is missing
DIGITAL:LOW8_SWICHT, typo in name
C5:COUPLING? typo in name
11. Fixed the Bode Plot bug: Sometime there isn’t enough
delay after the scope switches timebase values before it
tries to take a measurement
12. Fixed the bug : Matlab can’t import 14 M Matlab
waveform files
13. Fixed the bug:‘WF?’command ignores the length set
by ‘WFSU’ for digital
1. Supported Sign as a math function
2. Updated the Webserver. The built-in bin2csv tool supported to convert
binary data of digital channels
3. Added English help information
4. Fixed several bugs
1. Modify the PID of the DMM according the latest rules.
2. Bug fix: In the save function, When the file’s name is too long, the system will perhaps be crashed.
1. Supported Power Analysis (optional) (Analysis | Power Analysis)
2. Supported Bode Plot (Analysis | Bode Plot)
3. Supported Totalizer (Analysis | Counter). Frequency and period
parameters are moved from DVM to Counter
4. Supported 2 math traces and formula editor
5. Optimized FFT
a) Optimized menu structure
b) Supported peak and marker (Math | FFT | Tools)
c) Supported setting max points (Math | FFT | Config)
6. Measurement enhanced
a) Optimized the UI. In the “Basic” tab the items can be customized
(long pressing an item to add to or delete from Basic tab)
b) Added items: Median, Cycle median, -Bwidth, Time@max,
Time@min, 20-80%Rise, 80-20%Fall, +Area, -Area, Area,
AbsArea, Cycles, Rising Edges, Falling Edges, Edges, PPulses,
Npulses
c) Supported statistics on maximum 12 parameters at the same time (M2);
d) Optimized measurement accuracy of Rise/fall
e) Supported Trend Plot of measurement items
7. Optimized UX of knobs
8. Set the default function of the universal knob as adjusting the trace
intensity
9. Optimized SPO display
10. Supported moving the location of the decode buses vertically
11. Supported single step back or forward in Navigator
12. Added bandwidth limit indicator below 2.45mV/div (1GHz,
500MHz)/1mV/div(350MHz
13. Supported Zone trigger in Sequence mode
14. Added entry for Zone trigger in the right side trigger menu
15. Mask Test: Supported failed history (Mask Test | Failure to History)
16. Increased frequency setting digits of the AWG from 3 to 7
17. After gesture control of the vertical gain, the v/div knob still is in the
mode that has been used before with the gesture controls.
18. UART/LIN decode/trigger: supported baud rate > 5Mb/s
19. Reference position: Added user defined delay
20. Optimized UI in Zoom mode
21. Deleted the SCPI command which can start Telnet
22. Supported tapping on zone/histogram region to open the
corresponding menu
23. Fixed several bugs
1. Added SCPI command to set up gated measurements
and return the data.
2. Customers can save the result of decode list table to a
CSV file.
3. Modified the color of FFT to match the trace selected.
4. There are some times of quick calibration during warming
up the SDS XE. Added a menu below Utility to disable the
quick calibration so that the sampling isn’t interrupted.
5. Created software that converts binary waveform data to
CSV. It can be downloaded from the embedded web
server on the scope.
6. Fixed the bug: “Screen Save” button on web page does
not work with some browsers.
7. Fixed the bug: The setting of Educational mode can’t be
saved after power off.
8. Fixed a bug with MSO decoding. and the SLA1016
firmware also needs to be updated to 8.1.11.
9. Fixed the bug: The binary block returned by the
WAVEFORM command contains the length of the block
in the “#9” header. This length is incorrect when the NP
option of the WFSU command is used; the header then
gives the memory depth instead of the actual size of the
block.
10. Fixed the bug of the scope response from the
WAVEFORM command prefixes the binary block with the
string “ALL,” even when “CHDR OFF” is used.
11. Added exiting the on-screen keyboard by OK button.
1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
2. Fixed the OBW – Transmit Freq Error bug
3. Fixed the LOG scale –Correction display error
4. Fixed some marker and display text bugs
5. Add “UNCAL ”warning when setting changed after TG normalization
6. Add “Select All” in File-Operate menu
7. Add peak table “Sort By Freq/Ampt“ menu in Peak-Search Config
8. Optimize Freq Offset to 10 GHz, Scale/Div to 0.1 dB
9. Optimize several SCPI commands, such as *OPC? ,ESR? , etc.
10. Optimize .sta file limit parameters, Optimize .csv file parameters
1. Optimized communication between SDS1xx4X-E and
SLA1016. This revision (and higher) requires the SLA1016
MUST be upgraded to 8.1.16 (or higher) first. Please take
a look at ‘Compatibility with SLA1016’ at the end of
the release notes.
2. AWG Optimized Bode Plot: Accuracy and Sensitivity
Improvement, New Vari-level Mode for Testing Loop
Response, Miscellaneous Function and UI Improvements.
3. Optimized FFT UI: Added Peaks, Markers, and search
within FFT.
4. Optimized accessing USB drive so that when a USB drive
is moved to a computer, Windows will not prompt a
restoration of the USB drive.
5. Optimize WIFI connection: 63 characters can now be used
for a WPA2 PSK key.
6. Added parity options of MARK/SPACE for UART of 9-bit
Decode.
7. Optimized behavior of the cursors (x-axis): Added a
mode that the cursors remain at the set position on the
waveform when changing time base.
8. Optimize self-calibration for channels. (Recommend to
perform a self-calibration after upgrading.)
9. Added a pop message: If there are too many serial frames
in one sample, the Scope does not decode all of the serial
frames and pop up message of ‘Decoding to maximum
frame number limitation!’
10. Fixed the bug of ROV measurement.
11. Fixed the bug: Normal trigger can show more-than-one
trigger event on the display at one time.
12. Fixed the bug: Erratic triggering, randomly jumping
between the first and the second edge of a signal.
13. Fixe the bug: The acquire time of history is reset to zero
if the time reach 1 hour and 11 minutes. The delta time is
also wrong if the period is longer than 1 hour and 11
minutes.
14. Fixed The SPI triggering issue: the 16-bit trigger wouldn’t
work for a gap >360 ns between the two 8-bit packets.
15. Fixed the bug: Save/Recall setup of trigger and scale
issue.
( SalesForce ID:P-00199) (SalesForce ID:P-00200)
16. Fixed the bug: Reading cursors by SCPI is not accuracy.
(SalesForce ID:P-00201)
17. Fixed the bug: In fine adjust mode, some scale such as
302 mV/DIV is in the wrong position.
18. Fixed the bug: LIN decoder doesn’t decode frames with
zero-length response.
19. Fixed the bug: If the Courser Offset is not a multiple of
zoom time base, the curser will be replaced when
zoomed.
20. Fixed the bug: The measurements made with the cursor
in Ref. Give wrong values for all the different probes of
X1.
21. Fixed the bug: Measures fairs with GATE give completely
random values in signals of low frequency.
1. Added SCPI command to set up gated measurements
and return the data.
2. Customers can save the result of decode list table to a
CSV file.
3. Modified the color of FFT to match the trace selected.
4. There are some times of quick calibration during warming
up the SDS XE. Added a menu below Utility to disable the
quick calibration so that the sampling isn’t interrupted.
5. Created software that converts binary waveform data to
CSV. It can be downloaded from the embedded web
server on the scope.
6. Fixed the bug: “Screen Save” button on web page does
not work with some browsers.
7. Fixed the bug: The setting of Educational mode can’t be
saved after power off.
8. Fixed a bug with MSO decoding. and the SLA1016
firmware also needs to be updated to 8.1.11.
9. Fixed the bug: The binary block returned by the
WAVEFORM command contains the length of the block
in the “#9” header. This length is incorrect when the NP
option of the WFSU command is used; the header then
gives the memory depth instead of the actual size of the
block.
10. Fixed the bug of the scope response from the
WAVEFORM command prefixes the binary block with the
string “ALL,” even when “CHDR OFF” is used.
11. Added exiting the on-screen keyboard by OK button.
1. Fixed the bug: Once the acquisition is stopped, the scope
often can’t find search events in other channels.
2. Fixed the bug: In certain situations, the scope freezes
when the Auto Setup button is pressed.
3. Fixed the bug: The Pass/Fail mask is not correct at edge
of screen left and right.
4. Attenuation and invert indicator were added into the
channel tab.
5. Any arbitrary probe factor from 1e-6 to 1e6 can be set by
universal knob.
6. Got rid of suffix ‘A’ that stands for ‘Acknowledge’ from
I2C decode.
7. Fixed the bug: The dedicated window for long I2C data
sometime lose data at right edge.
8. Fixed the bug: The decoder sometimes does not show
any info.
9. Fixed the bug: After updating to the last firmware and OS
version, the remote panel/control interface can no longer
be connected.
2. Added Bode Plot support for all of Siglent’ s SDG
instruments
3. Fixed a bug in 6.1.20 which maybe cause the signal
disappear after self-calibration for channels
1. Add U disk recovery function.
2. Modify Hold function arithmetic.
3. Add the telnet SCPI function; port is 5024 Example: telnet 192.168.0.10 5024
4. Repair the external trig problem.
1. Add U disk recovery function
2. Add the update of the calibration data function
3. Fix the bug of a few abnormal DCV measurements when the input terminal is shorted
4. Repair the external trigger problem
5. Add the telnet SCPI function; port is 5024
Example: telnet 192.168.0.10 5024
6. FPGA optimization
1. Repaired bug causing Math error when trace is stopped in dot
display mode
2. Fixed ‘add measurement’ error in Polish language
3. Bug repaired when measuring frequency of 500 Hz, using
alternate trigger, and a time base of greater than 1 ms/div
1. Repaired bug causing Math error when trace is stopped in dot
display mode
2. Fixed ‘add measurement’ error in Polish language
3. Bug repaired when measuring frequency of 500 Hz, using
alternate trigger, and a time base of greater than 1 ms/div
1. Fixed condition where wave trace departs from zero line while
there is offset
2. Fixed condition where wave trace departs from zero line while
there is offset
3. Fixed bug: All measurements on, select source on a disable
channel. Reboot the Scope, then the software hangs on the
boot screen
4. Adjusted keyboard scan method to optimize recognizing
keyboard value
5. Modified BMP from 24bit to 16bit while save/get BMP form
Scope
6. Fixed the bug: Wave trace disappear after STOP in scan
mode
1. Fixed condition where wave trace departs from zero line while
there is offset
2. Fixed bug: Sample rate of zoom changed after STOP in dot
display mode
3. Fixed bug: All measurements on, select source on a disable
channel. Reboot the Scope, then the software hangs on the
boot screen
4. Adjusted keyboard scan method to optimize recognizing
keyboard value
5. Modified BMP from 24bit to 16bit while save/get BMP form
Scope