Digital Oscilloscopes

SDS5000X Series

SDS5000X

Bandwidth

1 GHz

Real time sampling rate

5 GSa/s

Channels

2/4 + EXT

SDS5000X

SDS5000X

Created with Pixso.

Product Introduction

SIGLENT SDS5000X series digital oscilloscopes are designed for high-performance testing needs. The series offers an analog bandwidth of 350 MHz to 1 GHz, a sampling rate of up to 5 GSa/s, and a memory depth of 250 Mpts to ensure the capture of fine signal details. Supporting a wide range of advanced features such as baud graphs, power analysis software and multiple serial protocol triggering and decoding, they are ideal for engineers and researchers.

Key Features

  • Bandwidth:350 MHz, 500 MHz, 1 GHz
  • Real-time sampling rate:5 GSa/s
  • Memory depth:250 Mpts
  • Waveform capture rate:500,000 wfm/s (Sequence mode)
  • Mixed Signal Measurement (MSO)

Product advantage

Multi-touch, remote control

The SDS5000X features a large 10.1” display capacitive touch screen supports multi-touch gestures, with the addition of user-friendly one-button design for most commonly used functions, can greatly improve the operation efficiency of the SDS5000X. It also supports mouse and external keyboard control.
 
It also offers webserver, which allowed for remote control on PC and mobile terminals without installing large-capacity drivers and Free PC software supporting  SCPI programming commands.

Multiple Trigger Types

The SDS5000X supports up to 11 intelligent trigger types that will quickly trigger signals of different characteristics. For example, using the Runt trigger can quickly trigger the Runt signal at the setup amplitude.
 
Special signals using traditional trigger types may require a setup step of approximately 20 steps. For this reason, the SDS5000X adds zone trigger. The complex signal can be ”one-step triggered” by simply drawing the trigger area box.
 
The trigger source supported by the SDS5000X includes 4 analog channels, 16 digital channels, EXT, EXT/5, AC Line.

Serial Triggering and Decoding

The SDS5000X offers a wide range of serial protocol triggering and decoding across multiple industries.

I2C, SPI Embedded serial protocol triggering and decoding
UART PC Serial Protocol Trigger and Decode
CAN, CAN FD, LIN, FlexRay Automotive serial protocol triggering and decoding
I2S Audio serial protocol triggering and decoding
MIL-STD 1553B Flight System Serial Protocol Triggering and Decoding

Powerful Measurement Functions

The SDS5000X currently supports over 55 parameter measurements. The advanced measurement function measures 12 parameters simultaneously and displays the trend of the parameter values in the form of a trend graph. The current value of the parameter, average, minimum, maximum, standard deviation and number of statistics are displayed on the screen when you turn on the statistics function. 
 
The source for the measurement includes analog and digital channels as well as signals after Zoom, MATH waveforms, and Ref waveforms.

8-in-1 Instrument

The SDS5000X combines a variety of functions in one unit, greatly saving space and providing more value to the user.

16-channel Logic Analyzer
25 MHz Isolated Signal Source Module, which can be used with the baud plot function for power loop response testing
Template Testing
Digital Multimeter
Baud Plot Function
Power Supply Analysis Software
Counter
Frequency Counter

Product parameter

Comparative Data SDS5000X Tektronix 3 SeriesMDO Keysight 3000T XSeries
Bandwidth 350 MHz - 1 GHz 100 MHz - 1 GHz 100 MHz - 1 GHz
Channels 2/4 + EXT 2/4 + EXT 2/4 + EXT
Sample Rate(Max.) 5 GSa/s 5 GSa/s 5 GSa/s
Waveform Capture Rate (Max.) 500,000 wfm/s 280,000 wfm/s 1,000,000 wfm/s
Memory Depth (Max.) 250 Mpts 10 Mpts 4 Mpts
Intensity Grading and Color Temperature Display 256-level Intensity Grading and Color Temperature Display 256-level Intensity Grading and Color Temperature Display 64-level Intensity Grading and Color Temperature Display
Vertical Sensitivity 500 μV/div ~10 V/div 1mV~10V/div 1 mV/div ~ 5 V/div
Sequence Mode Support,100,000 frames Not Support Support,1000 frames
History Mode Support,100,000 frames Not Support Not Support
FFT 2 Mpts N/A 64 kpts
MASK Test Standard Optional Optional
Display 10.1 inch touch screen 11.6 inch touch screen 8.5 inch touch screen
Price - $4,480 ~ $4,044 ~

* Note: The above prices and parameters were collected in official website on January 10th, 2024. In case of any discrepancy, the official website shall prevail.

Configure your instrument

Add to Compare ModelsBandwidthChannelsADCSampling rateMemory depthCapture rate Price  

Resources

Probe (Standard)
Created with Pixso. Created with Pixso.

Product
Description
SP3050A
SP3050A

Passive probe, 500 MHz bandwidth, 10X attenuation ratio, input impedance of 11pF || 10MΩ, with automatic identification function.

Click to view the probe manual.

Other
Created with Pixso. Created with Pixso.

Probe (Standard)
Created with Pixso. Created with Pixso.

Product
Description
SPL2016
SPL2016

16-channel logic probe (hardware), sampling rate and storage depth are determined by oscilloscope, which is suitable for dingyang technology SDS7000A, SDS6000 Pro, SDS6000L, SDS5000X HD, SDS5000X, SDS3000X HD, SDS2000X HD and SDS2000X Plus models.

Click to view the probe manual.

HPB4010
HPB4010

High voltage probe, DC-40 MHz bandwidth, 1000X attenuation ratio, input impedance 3pF || 100MΩ.

Click to view the probe manual.

SAP1000
SAP1000

Active single-ended probe, 1 GHz bandwidth, 10X attenuation ratio, input impedance of 1.2pF || 1MΩ, offset range of ±12V, SAPBus interface.

Click to view the probe manual.

SAP2500
SAP2500

Active single-ended probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, input impedance of 1.1pF || 1MΩ, offset range of ±12V, SAPBus interface.

Click to view the probe manual.

SAP2500D
SAP2500D
Active differential probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, differential input impedance of 1pF || 200kΩ, offset range of 8V, SAPBus interface.
TPA10
TPA10
The active probe interface of Dingyang oscilloscope SAPBus with TPA10 probe adapter can be used to adapt the active probe of Tektek TekProbe interface level II interface, which can supply power and DC bias for the probe without external power supply or other circuits.
SAP4000P
SAP4000P
Power rail probe, DC-4 GHz bandwidth, 1.1X attenuation ratio, input dynamic range ±600mV, offset range ±24V, SAPBus interface.
CP4020
CP4020

Current probe, DC-300 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply.

Click to view the probe manual.

CP4050
CP4050

Current probe, DC-1 MHz bandwidth, 2X/20X attenuation ratio, maximum input 50Arms/140Ap-p, 9V adapter power supply.

Click to view the probe manual.

CP4070
CP4070

Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.

Click to view the probe manual.

CP4070A
CP4070A

Current probe, DC-300 kHz bandwidth, attenuation ratio of 10X/100X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply.
Click to view the probe manual.

CP6030
CP6030

Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.

Click to view the probe manual.

CP6030A
CP6030A

Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.

Click to view the probe manual.

CP6150
CP6150

Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.

Click to view the probe manual.

CP6500
CP6500

Current probe, DC-5 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, powered by 12V adapter.

Click to view the probe manual.

SCP5030
SCP5030

Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, SAPBus interface.

Click to view the probe manual.

SCP5030A
SCP5030A

Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, SAPBus interface.

Click to view the probe manual.

SCP5150
SCP5150

Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.

Click to view the probe manual.

SCP5500
SCP5500

Current probe, DC-2 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, SAPBus interface.

Click to view the probe manual.

CPL5100
CPL5100
Current probe, DC-600 kHz bandwidth, attenuation ratio of 10X/100X, current range of 50mA ~ 100Apk, powered by 12V adapter.

Other
Created with Pixso. Created with Pixso.

Trigger/decode Options
Created with Pixso. Created with Pixso.

Product
Description
SDS-5000X-1553B
SDS-5000X-1553B
MIL-STD-1553B Trigger/decode option
SDS-5000X-CANFD
SDS-5000X-CANFD
CAN FD Trigger/decode option
SDS-5000X-FlexRay
SDS-5000X-FlexRay

FlexRay Trigger/decode option

SDS-5000X-I2S
SDS-5000X-I2S

IISTrigger/decode option

SDS-5000X-SENT
SDS-5000X-SENT

SENT Protocol Trigger and Decoding Kit (Software)

SDS-5000X-Manch
SDS-5000X-Manch

Manchester protocol decoding (software)

SDS-5000X-ARINC
SDS-5000X-ARINC

ARINC429 trigger & decode

Bandwidth/Channel Upgrade Options
Created with Pixso. Created with Pixso.

Hide Created with Pixso.