SIGLENT’s SDS6000A series Digital Storage Oscilloscopes are available in bandwidths of 2 GHz, 1 GHz, and 500 MHz, have a sample rate of 5 GSa/s (10 GSa/s ESR) at each channel, a maximum record length of 500 Mpts, and display up to 4 analog channels + 16 digital channels mixed-signal analysis ability.
Key Features
Bandwidth: 500 MHz, 1 GHz, 2 GHz
ADC:8-bit
Real time sampling rate:5 GSa/s (10 GSa/s ESR) ADC per analog channel
Record Length up to 500 Mpts
Waveform capture rate up to 750,000 wfm/s (Sequence mode)
Product advantages
Achieve more with SDS6000A oscilloscope
SDS6000A comes with even more memory depth. 500 Mpts and a hardware-based zoom.
The sample rate is up to 5 GSa/s (10 GSa/s ESR) per channel, even when you use all four channels at the same time. No compromises.
Modern form factor balances ease-of-use and desk space
SDS6000A is easy to move around the lab and occupy small desk space. The big 12.1 inch and high resolution touch screen provides intuitive control and clear information for faster debugging. It is also easily customized, you can choose your favorite channel traces colors, default settings, menu styles, measurement formats and so on. The faster UI response of SDS6000A makes R&D work even more pleasing.
Eye/Jitter analysis
Troubleshoot high-speed digital circuits more effectively using the Jitter Analysis option. Delivers Eye Diagram and Jitter analysis including jitter decomposition information and more.
Excellent Operability
SAP1000 active probe was released with SDS5000X oscilloscope. This time SDS6000A comes with two newly designed active probes. SAP2500 is single ended via SAP2500D is 2.5 GHz differential active probe. With the Eye diagram/ Jitter analysis functions, SDS6000A is more capable in high speed circuits design and signal integrity measurements.
Capacitive touch screen, supports multi-touch gestures, traces can be moved or scaled efficiently by a finger touch
Built-in web server supports remote control over the LAN port using a web browser
External mouse and keyboard support
Triggering and decoding of serial protocols covering various industries
SDS6000A provides a variety of serial protocol triggering and decoding, such as I2C, SPI, UART, CAN, CAN FD, LIN, FlexRay, SENT, I2S, MIL-STD-1553B, Manchester, ARINC429, covering many industries such as embedded, automotive, audio and wireless communication.
1. UI process control, which improves UI processing efficiency
2. Added the feature to limit the number of display digits of measurements
3. Added a Run/Stop button to the Quick Settings panel
4. Roll mode now supports Track cursors and measurement statistics; Math is supported in Roll mode when the acquisition is stopped
5. Cursors: supports multiple cursor groups (multiple cursors)
6. Measure:
a) Added measurement items: Bit Rate and Data Rate;
b) Tapping a measurement item opens a pop-up dialog for quick setup of measurement parameters;
c) In M2 display mode of advanced measurement, up to 24 measurement items can be displayed simultaneously; supports Time@Level, △TimeMax, △TimeMin, Track plot (for small-target measurement), Math Track plot, Trend plot, and Math Trend plot
7. Bus protocols: supports USB 2.0, CAN XL, SpaceWire, SPMI, 8b10b, and RFFE
8. Option types: added USB 2.0, CAN XL, SpaceWire, SPMI, 8b10b, and RFFE options
9. File storage: supports saving all frames of Sequence data into a single file — the multi-frame storage function is enabled once Sequence is turned on; also supports saving multiple channels into a single file
10. Added password setting for the screen saver
11. Added Math and memory waveforms as selectable sources
1. FFT: supported horizontal log axis
2. Channel: optimized strategy of adding a trace
3. Fixed several bugs
a) Bode plot: load and sweep settings not remembered; no virtual keypad for setting of some parameters
b) ARINC429 trigger not work on SDS6104 Pro
1. Eye Diagram: supported 100Base-T1 (PAM3)
2. SCPI: Supported Search
3. Supported USB-GPIB
4. Fixed several bugs
a) DY-WTFK-202203165613:Spectrum menu after installing
b) DY-WTFK-202209237014: Scope restarts acquisition after few
seconds when stopped
c) DY-WTFK-202207076348: Filter settings way off in special
acquisition modes
d) DY-WTFK-202209237015: Zone trigger doesn’t work at some
input frequencies
1. Force trigger strategy changed (same as SDS2000X HD)
2. Save/Recall
a) Supported to save all sequence segments
b) Supported Auto Save
3. Fixed several bugs
a) Cannot communicate with the SDG2000X and SDG7000A over
USB in Bode Plot
b) Random +/-200 ps skew between channels after power/reboot
cycle
c) [Power analysis] – Switching losses – Error in calculations
d) FFT wrong vertical scale
e) Memory channel trace always on top
Note: This release cannot be downgraded to former releases.
1. Math: added filter operator
2. Supported to save waveform as Memory traces, which store the raw
data instead of the screen data (as Ref does), and can be source of
Measure/Math etc.
3. Measure: improved the AIM limit from 1,000 to up to 65,000 (AIM limit:
the upper limit of horizontal parameters measure statistics in one
frame )
4. Optimized intensity display of math traces.
5. Added support for mouse wheel when using a mouse
6. Supported CP030 current probe (with LPA10 adapter)
7. Eye Diagram: 100Base-TX signal supported
8. Trigger: Pattern trigger strategy changed
9. Power Analysis:
a) Supported MOSFET SOA (Safe Operating Area)
b) Bigger table size
10. Fixed several bugs
a) Moving the traces by gestures may cause the scope to freeze
b) [Bode Plot]Vertical Ref.level manual setting is partially bad
c) [Measure]Track plot – not working well in general
d) [Power Analysis]Current harmonics forgets table/bar view
e) Waveform Capture Rate breakdown at 20 ns/div
f) Measurements skip buffers in history mode
1. Channel: two custom probe ratio options supported
2. Fixed several bugs
a) Bode Plot draw error (missing draw)
b) Bode Plot – Very slow, nearly stuck, with some signal levels
c) Counter – totalizer not showing all numbers
d) Counter (time period) shows incredible numbers
USB-A to USB-B. Used to connect instrument to PC for communication.
wireless mouse
A wireless mouse comes standard to help you improve your operating experience.
Power cord
The instrument comes standard with a power cord that conforms to the national standard of the user. Additional power cords in different regions can be purchased separately.
SDS6000A Quick Start
QuickStart of SDS6000A series oscilloscopes as standard.
Protective Cover
Fasten on the front panel of the machine to protect the touch screen and knob to prevent the machine from being damaged by collision.
Probe
Product
Description
SP6150A
Passive probe, 1.5 GHz bandwidth, 10X attenuation ratio, input impedance of 1.8pF || 500Ω, with automatic identification function.
Active differential probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, differential input impedance of 1pF || 200kΩ, offset range of 8V, SAPBus interface.
High voltage differential probe, bandwidth of 70 MHz, attenuation ratio of 50X/500X, maximum differential voltage of ±1500V, differential input impedance of 2pF || 10MΩ, BNC interface.
Current probe, DC-300 kHz bandwidth, attenuation ratio of 10X/100X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply. Click to view the probe manual
CP6030
Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.
16-channel logic probe (hardware), sampling rate and storage depth are determined by oscilloscope, which is suitable for SIGLENT technology SDS7000A, SDS6000A, SDS6000L, SDS5000X HD, SDS5000X, SDS3000X HD, SDS2000X HD and SDS2000X Plus models.
USB arbitrary waveform generator SAG1021I (isolated)
USB arbitrary waveform generator module (isolated) integrates sine wave, square wave, triangular wave, pulse wave, noise, DC and 45 kinds of built-in arbitrary waves. Users can also edit arbitrary waveforms through EasyWave PC software.
STB-3 Demo board
Signals include various sine and square waves, AM, burst, and common serial bus signals.
USB-GPIB Adapter
Expand the instrument’s USB interface into a GPIB interface. Using GPIB commands allows for easier execution of various operational tasks. The USB interface adheres to the USB 2.0 specification, while the GPIB interface complies with the IEEE 488.2 standard.
DF2001A
The phase calibration board, used in conjunction with power analysis software, is used to calibrate the phase difference generated by the voltage and current probes during transmission.
CASE-S1
Transport protective box,suitable for SNA5000A,SDS6000A ,SSA5000A,SDS5000X and SDS3000X-HDseries.